不同程度的CT饱和度会产生多大的测量误差?

Douglas M. Millner
{"title":"不同程度的CT饱和度会产生多大的测量误差?","authors":"Douglas M. Millner","doi":"10.1109/CFPR57837.2023.10127052","DOIUrl":null,"url":null,"abstract":"Current transformer saturation is normal occurrence in the field. The system often has been reconfigured or strengthened since the current transformer was put into place. This often results in higher available fault current, which can lead to CT saturation during faults. Usually, the degree of saturation due to AC and DC fault current is not enough to cause the system to misoperate, but is enough to introduce measurement error to the relay. Other times, it causes the relaying to trip/malfunction. Replacing CTs that occasionally saturate during faults often times is impractical and unnecessary.","PeriodicalId":296283,"journal":{"name":"2023 76th Annual Conference for Protective Relay Engineers (CFPR)","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"How much measurement error can someone expect from various degrees of CT saturation?\",\"authors\":\"Douglas M. Millner\",\"doi\":\"10.1109/CFPR57837.2023.10127052\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Current transformer saturation is normal occurrence in the field. The system often has been reconfigured or strengthened since the current transformer was put into place. This often results in higher available fault current, which can lead to CT saturation during faults. Usually, the degree of saturation due to AC and DC fault current is not enough to cause the system to misoperate, but is enough to introduce measurement error to the relay. Other times, it causes the relaying to trip/malfunction. Replacing CTs that occasionally saturate during faults often times is impractical and unnecessary.\",\"PeriodicalId\":296283,\"journal\":{\"name\":\"2023 76th Annual Conference for Protective Relay Engineers (CFPR)\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 76th Annual Conference for Protective Relay Engineers (CFPR)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CFPR57837.2023.10127052\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 76th Annual Conference for Protective Relay Engineers (CFPR)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CFPR57837.2023.10127052","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

电流互感器饱和在现场是正常现象。自电流互感器投入使用以来,该系统经常被重新配置或加强。这通常会导致更高的可用故障电流,从而在故障期间导致CT饱和。通常,由于交流和直流故障电流引起的饱和程度不足以引起系统误操作,但足以给继电器引入测量误差。其他时候,它会导致继电器跳闸/故障。更换偶尔在故障期间饱和的ct通常是不切实际和不必要的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
How much measurement error can someone expect from various degrees of CT saturation?
Current transformer saturation is normal occurrence in the field. The system often has been reconfigured or strengthened since the current transformer was put into place. This often results in higher available fault current, which can lead to CT saturation during faults. Usually, the degree of saturation due to AC and DC fault current is not enough to cause the system to misoperate, but is enough to introduce measurement error to the relay. Other times, it causes the relaying to trip/malfunction. Replacing CTs that occasionally saturate during faults often times is impractical and unnecessary.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Fault location for multi-terminal lines A Tale of Two Out-of-Phase Synchronizing Events at BC Hydro Use of DFR's for Distribution Substation Monitoring Export Cable Protection for Offshore Wind Farms Using Type-IV Wind Turbine Generators Electromechanical Differential Relays Misoperation and Investigation. Part 2
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1