东海地区IVR剂量管理问卷调查

Nihon Hoshasen Gijutsu Gakkai zasshi Pub Date : 2024-01-20 Epub Date: 2023-11-15 DOI:10.6009/jjrt.2024-1342
Mitsuharu Osawa, Akinori Nagata, Takaya Saijo, Tsuyoshi Yamada, Naruto Sugimoto, Akira Tokudome, Kosuke Suzuki, Hajime Sakamoto
{"title":"东海地区IVR剂量管理问卷调查","authors":"Mitsuharu Osawa, Akinori Nagata, Takaya Saijo, Tsuyoshi Yamada, Naruto Sugimoto, Akira Tokudome, Kosuke Suzuki, Hajime Sakamoto","doi":"10.6009/jjrt.2024-1342","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>National diagnostic reference levels in Japan 2020 (DRLs 2020) have been published. In the field of angiography, in addition to the fluoroscopic dose rate, incident air kerma at the patient entrance reference point displayed on the equipment (K<sub>a,r</sub>: mGy) and air kerma-area product displayed on the equipment (P<sub>KA</sub>: Gycm<sup>2</sup>) were set. A questionnaire survey was conducted at each facility in the Tokai region to confirm the status of medical radiation dose control in the region.</p><p><strong>Method: </strong>A questionnaire survey was conducted at each facility in the Tokai region. The items were fluoroscopic dose rate in each area (head and neck, cardiac, chest and abdomen, and limbs), DA and DSA dose rates, and dose area product meter (K<sub>a,r</sub>, P<sub>KA</sub>) for the main procedures in each area.</p><p><strong>Result: </strong>The median values in this study were lower than those in the DRLs 2020, indicating that appropriate dose control is being implemented in the Tokai region. The trends of fluoroscopic and radiographic dose rates were different in each area, and there was some variation among the facilities.</p><p><strong>Conclusion: </strong>We believe that the incorporation of fluoroscopic and radiographic dose rates by area into the DRLs will facilitate more appropriate dose control at each facility in the future.</p>","PeriodicalId":74309,"journal":{"name":"Nihon Hoshasen Gijutsu Gakkai zasshi","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-01-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Questionnaire Survey on IVR Dose Management in Tokai Region].\",\"authors\":\"Mitsuharu Osawa, Akinori Nagata, Takaya Saijo, Tsuyoshi Yamada, Naruto Sugimoto, Akira Tokudome, Kosuke Suzuki, Hajime Sakamoto\",\"doi\":\"10.6009/jjrt.2024-1342\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>National diagnostic reference levels in Japan 2020 (DRLs 2020) have been published. In the field of angiography, in addition to the fluoroscopic dose rate, incident air kerma at the patient entrance reference point displayed on the equipment (K<sub>a,r</sub>: mGy) and air kerma-area product displayed on the equipment (P<sub>KA</sub>: Gycm<sup>2</sup>) were set. A questionnaire survey was conducted at each facility in the Tokai region to confirm the status of medical radiation dose control in the region.</p><p><strong>Method: </strong>A questionnaire survey was conducted at each facility in the Tokai region. The items were fluoroscopic dose rate in each area (head and neck, cardiac, chest and abdomen, and limbs), DA and DSA dose rates, and dose area product meter (K<sub>a,r</sub>, P<sub>KA</sub>) for the main procedures in each area.</p><p><strong>Result: </strong>The median values in this study were lower than those in the DRLs 2020, indicating that appropriate dose control is being implemented in the Tokai region. The trends of fluoroscopic and radiographic dose rates were different in each area, and there was some variation among the facilities.</p><p><strong>Conclusion: </strong>We believe that the incorporation of fluoroscopic and radiographic dose rates by area into the DRLs will facilitate more appropriate dose control at each facility in the future.</p>\",\"PeriodicalId\":74309,\"journal\":{\"name\":\"Nihon Hoshasen Gijutsu Gakkai zasshi\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nihon Hoshasen Gijutsu Gakkai zasshi\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.6009/jjrt.2024-1342\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/11/15 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nihon Hoshasen Gijutsu Gakkai zasshi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.6009/jjrt.2024-1342","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/15 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:日本2020年国家诊断参考水平(DRLs 2020)已经发布。在血管造影领域,除设置透视剂量率外,还设置设备上显示的患者入口参考点入射风角(Ka,r: mGy)和设备上显示的风角面积积(PKA: Gycm2)。在东海地区的每个设施进行了问卷调查,以确认该地区医疗辐射剂量控制的状况。方法:对东海地区各医院进行问卷调查。项目为各区域(头颈、心脏、胸腹、四肢)的透视剂量率、DA和DSA剂量率、各区域主要手术的剂量面积积计(Ka、r、PKA)。结果:本研究的中位数低于2020年DRLs的中位数,表明东海地区正在实施适当的剂量控制。不同地区的透视和放射剂量率变化趋势不同,不同的设施也有一定的差异。结论:我们认为,在DRLs中纳入按区域划分的透视和放射剂量率将有助于在未来各机构进行更适当的剂量控制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Questionnaire Survey on IVR Dose Management in Tokai Region].

Purpose: National diagnostic reference levels in Japan 2020 (DRLs 2020) have been published. In the field of angiography, in addition to the fluoroscopic dose rate, incident air kerma at the patient entrance reference point displayed on the equipment (Ka,r: mGy) and air kerma-area product displayed on the equipment (PKA: Gycm2) were set. A questionnaire survey was conducted at each facility in the Tokai region to confirm the status of medical radiation dose control in the region.

Method: A questionnaire survey was conducted at each facility in the Tokai region. The items were fluoroscopic dose rate in each area (head and neck, cardiac, chest and abdomen, and limbs), DA and DSA dose rates, and dose area product meter (Ka,r, PKA) for the main procedures in each area.

Result: The median values in this study were lower than those in the DRLs 2020, indicating that appropriate dose control is being implemented in the Tokai region. The trends of fluoroscopic and radiographic dose rates were different in each area, and there was some variation among the facilities.

Conclusion: We believe that the incorporation of fluoroscopic and radiographic dose rates by area into the DRLs will facilitate more appropriate dose control at each facility in the future.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Long-term Reproducibility Evaluation of Fluoroscopy Dose Rate in Angiography Equipment]. [Root Cause Analysis for Incident Reporting Cases of Radiological Technologists Based on Years of Experience]. [Effect of Training Data Differences on Accuracy in MR Image Generation Using Pix2pix]. [Noise Characteristics of Summary Maps for Brain CT Perfusion: A Simulation Study Using a Digital Phantom and Clinical Images]. [Effect of Pulse Wave Synchronization on T1 Value in Cardiac T1 Mapping: Is Pulse Wave Synchronization a Substitute for Electrocardiogram Gating?]
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1