一种结构简单的新型无损无源缓冲器,用于脉宽调制DC-DC变换器

Mahmood Vesali
{"title":"一种结构简单的新型无损无源缓冲器,用于脉宽调制DC-DC变换器","authors":"Mahmood Vesali","doi":"10.12962/jaree.v7i2.358","DOIUrl":null,"url":null,"abstract":"A new lossless passive snubber for pulse width modulation converters is introduced in this paper. This snubber is established zero current switching condition for main switch in the converters for turning on distance. This snubber does not impose any additional current stress on the switch. The snubber can be applied to all single-switch DC-DC converters. A boost converter with the proposed snubber is analyzed and to verify theoretical analysis a 200 W sample is implemented and tested, also the experimental results are presented. In order to investigate the effect of snubber circuit in the converter in terms of efficiency, the boost converter with the proposed snubber has been compared in terms of efficiency with the conventional boost converter and the results show that the efficiency has increased by about 7% despite the snubber.","PeriodicalId":32708,"journal":{"name":"JAREE Journal on Advanced Research in Electrical Engineering","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A new lossless passive snubber with simple structure for pulse width modulation DC-DC converters\",\"authors\":\"Mahmood Vesali\",\"doi\":\"10.12962/jaree.v7i2.358\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A new lossless passive snubber for pulse width modulation converters is introduced in this paper. This snubber is established zero current switching condition for main switch in the converters for turning on distance. This snubber does not impose any additional current stress on the switch. The snubber can be applied to all single-switch DC-DC converters. A boost converter with the proposed snubber is analyzed and to verify theoretical analysis a 200 W sample is implemented and tested, also the experimental results are presented. In order to investigate the effect of snubber circuit in the converter in terms of efficiency, the boost converter with the proposed snubber has been compared in terms of efficiency with the conventional boost converter and the results show that the efficiency has increased by about 7% despite the snubber.\",\"PeriodicalId\":32708,\"journal\":{\"name\":\"JAREE Journal on Advanced Research in Electrical Engineering\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-07-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JAREE Journal on Advanced Research in Electrical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.12962/jaree.v7i2.358\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JAREE Journal on Advanced Research in Electrical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12962/jaree.v7i2.358","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

介绍了一种用于脉宽调制变换器的新型无损无源缓冲器。该缓冲器为变流器主开关的开断距离建立了零电流开关条件。这种缓冲器不会对开关施加任何额外的电流压力。缓冲器可应用于所有单开关DC-DC转换器。为了验证理论分析的正确性,对一个200w的升压变换器进行了仿真和测试,并给出了实验结果。为了研究缓冲器电路对变换器效率的影响,将采用该缓冲器的升压变换器与传统升压变换器的效率进行了比较,结果表明,尽管有缓冲器,但效率提高了约7%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A new lossless passive snubber with simple structure for pulse width modulation DC-DC converters
A new lossless passive snubber for pulse width modulation converters is introduced in this paper. This snubber is established zero current switching condition for main switch in the converters for turning on distance. This snubber does not impose any additional current stress on the switch. The snubber can be applied to all single-switch DC-DC converters. A boost converter with the proposed snubber is analyzed and to verify theoretical analysis a 200 W sample is implemented and tested, also the experimental results are presented. In order to investigate the effect of snubber circuit in the converter in terms of efficiency, the boost converter with the proposed snubber has been compared in terms of efficiency with the conventional boost converter and the results show that the efficiency has increased by about 7% despite the snubber.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
10
审稿时长
24 weeks
期刊最新文献
A new lossless passive snubber with simple structure for pulse width modulation DC-DC converters Prosumer-Based Optimization of Educational Building Grid Connected with Plug-in Electric Vehicle Integration using Modified Firefly Algorithm Pencak Silat Movement Classification Using CNN Based On Body Pose Load Frequency Control by Quadratic Regulator Approach with Compensating Pole using SIMULINK Temperature and Humidity Control System for 20 kV of Cubicle with Multiple Input Multiple Output Fuzzy Logic Controller
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1