喙突骨折合并锁骨远端骨折1例

IF 0.3 Q4 ORTHOPEDICS Travmatologiya i ortopediya Rossii Pub Date : 2023-09-15 DOI:10.17816/2311-2905-14793
Alexander I. Avdeev, Dmitrii G. Parfeev, Danil D Parshin, Ekaterina V. Sinitsyna
{"title":"喙突骨折合并锁骨远端骨折1例","authors":"Alexander I. Avdeev, Dmitrii G. Parfeev, Danil D Parshin, Ekaterina V. Sinitsyna","doi":"10.17816/2311-2905-14793","DOIUrl":null,"url":null,"abstract":"Background. Fracture of the distal clavicle fracture associated with a coracoid process fracture is extremely rare in the practice of an orthopedic surgeon. Therefore, there is no common approach to the treatment of patients with this type of bone injuries of the shoulder girdle.
 Aim of the study to demonstrate positive experience of conservative treatment of the coracoid process fracture combined with hook plate fixation for distal clavicle fracture.
 Case presentation. We present a rare clinical case of a closed distal clavicle fracture associated with coracoid process fracture. Trauma occurred when the patient fell down the stairs on his abducted upper limb. After examination, the distal clavicle fracture was fixed with a hook plate. Intraoperatively, X-rays showed a satisfactory position of the coracoid process of the scapula. Therefore, it was decided not to fix it additionally. CT scans three months after the surgery showed bone fragments consolidation. Removal of the hook plate and screws from the clavicle was performed.
 Conclusion. Presented clinical case illustrates successful treatment result of this type of fractures without fixation of the coracoid process fracture. The hook plating allows to stabilize bone fragments and restore ligament tension, which makes this implant non-alternative for fixation of this type of injuries.","PeriodicalId":43463,"journal":{"name":"Travmatologiya i ortopediya Rossii","volume":null,"pages":null},"PeriodicalIF":0.3000,"publicationDate":"2023-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Coracoid Process Fracture Associated With a Distal Clavicle Fracture: A Case Report\",\"authors\":\"Alexander I. Avdeev, Dmitrii G. Parfeev, Danil D Parshin, Ekaterina V. Sinitsyna\",\"doi\":\"10.17816/2311-2905-14793\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background. Fracture of the distal clavicle fracture associated with a coracoid process fracture is extremely rare in the practice of an orthopedic surgeon. Therefore, there is no common approach to the treatment of patients with this type of bone injuries of the shoulder girdle.
 Aim of the study to demonstrate positive experience of conservative treatment of the coracoid process fracture combined with hook plate fixation for distal clavicle fracture.
 Case presentation. We present a rare clinical case of a closed distal clavicle fracture associated with coracoid process fracture. Trauma occurred when the patient fell down the stairs on his abducted upper limb. After examination, the distal clavicle fracture was fixed with a hook plate. Intraoperatively, X-rays showed a satisfactory position of the coracoid process of the scapula. Therefore, it was decided not to fix it additionally. CT scans three months after the surgery showed bone fragments consolidation. Removal of the hook plate and screws from the clavicle was performed.
 Conclusion. Presented clinical case illustrates successful treatment result of this type of fractures without fixation of the coracoid process fracture. The hook plating allows to stabilize bone fragments and restore ligament tension, which makes this implant non-alternative for fixation of this type of injuries.\",\"PeriodicalId\":43463,\"journal\":{\"name\":\"Travmatologiya i ortopediya Rossii\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.3000,\"publicationDate\":\"2023-09-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Travmatologiya i ortopediya Rossii\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17816/2311-2905-14793\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Travmatologiya i ortopediya Rossii","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17816/2311-2905-14793","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

背景。锁骨远端骨折合并喙突骨折在骨科手术中极为罕见。因此,对于这类肩带骨损伤患者的治疗尚无统一的方法。 目的探讨保守治疗喙突骨折联合钩钢板内固定治疗锁骨远端骨折的积极经验。案例演示。我们报告一例罕见的锁骨远端闭合性骨折合并喙突骨折的临床病例。创伤发生在病人从楼梯上摔下来,上肢外展。检查后,用钩钢板固定锁骨远端骨折。术中x光片显示肩胛骨喙突位置良好。因此,我们决定不再修复它。术后3个月的CT扫描显示骨碎片巩固。从锁骨上取下钩板和螺钉。 结论。本文的临床病例说明了这种类型的喙突骨折无固定治疗的成功效果。钩状钢板可以稳定骨碎片并恢复韧带张力,这使得该植入物不可替代地固定这类损伤。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Coracoid Process Fracture Associated With a Distal Clavicle Fracture: A Case Report
Background. Fracture of the distal clavicle fracture associated with a coracoid process fracture is extremely rare in the practice of an orthopedic surgeon. Therefore, there is no common approach to the treatment of patients with this type of bone injuries of the shoulder girdle. Aim of the study to demonstrate positive experience of conservative treatment of the coracoid process fracture combined with hook plate fixation for distal clavicle fracture. Case presentation. We present a rare clinical case of a closed distal clavicle fracture associated with coracoid process fracture. Trauma occurred when the patient fell down the stairs on his abducted upper limb. After examination, the distal clavicle fracture was fixed with a hook plate. Intraoperatively, X-rays showed a satisfactory position of the coracoid process of the scapula. Therefore, it was decided not to fix it additionally. CT scans three months after the surgery showed bone fragments consolidation. Removal of the hook plate and screws from the clavicle was performed. Conclusion. Presented clinical case illustrates successful treatment result of this type of fractures without fixation of the coracoid process fracture. The hook plating allows to stabilize bone fragments and restore ligament tension, which makes this implant non-alternative for fixation of this type of injuries.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.60
自引率
66.70%
发文量
56
审稿时长
8 weeks
期刊最新文献
Medium-term results of the treatment of periprosthetic infection with carbon-coated spacers impregnated with silver SUGGESTIONS FOR INTRODUCING SOME NEW TERMS IN PELVIC AND ACETABULAR SURGERY Correction of multiapical deformities of the lower libs: Review Knee arthroplasty in real clinical practice: analysis of 36,350 cases from the register of the Vreden National Medical Center of Trauma and Ortopedics ORTHOPEDICS IN THE FOCUS OF INTELLECTUAL PROPERTY
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1