{"title":"对现有x射线室辐射屏蔽计算方法的批判性分析","authors":"V. Yu. Golikov","doi":"10.21514/1998-426x-2023-16-3-13-21","DOIUrl":null,"url":null,"abstract":"The paper demonstrates the limitations of the existing methodology for calculating the radiation shielding of X-ray rooms presented in SanPin 2.6.1.1192-03. It is shown that the algorithm for calculating the attenuation coefficient by the barrier does not take into account the features of the attenuation of different components of X-ray radiation: direct, scattered, and leakage radiation, which differ in the region of occurrence, intensity, energy spectrum, and other parameters. Instead, a single formula is used for all components, and the differences in their attenuation are taken into account by a parameter the values of which for different radiation components are in no way justified and are questionable. The calculation also does not take into account the distribution of the workload of X-ray machines by the tube voltage, the significant attenuation of direct X-ray radiation by additional structures necessary for image acquisition. The values of the radiation output of X-ray machines recommended for shielding design in SanPiN 2.6.1.1192-03 are 2–3 times overestimated in relation to the measured values. This leads to an unreasonable overestimation of the requirements for the thickness of radiation shielding in X-ray rooms and accordingly to suboptimal spending on healthcare. It is necessary to develop a new document to replace SanPiN 2.6.1.1192-03.","PeriodicalId":496413,"journal":{"name":"Радиационная гигиена","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Critical analysis of the existing approach to the calculation of radiation shielding in X-ray rooms\",\"authors\":\"V. Yu. Golikov\",\"doi\":\"10.21514/1998-426x-2023-16-3-13-21\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper demonstrates the limitations of the existing methodology for calculating the radiation shielding of X-ray rooms presented in SanPin 2.6.1.1192-03. It is shown that the algorithm for calculating the attenuation coefficient by the barrier does not take into account the features of the attenuation of different components of X-ray radiation: direct, scattered, and leakage radiation, which differ in the region of occurrence, intensity, energy spectrum, and other parameters. Instead, a single formula is used for all components, and the differences in their attenuation are taken into account by a parameter the values of which for different radiation components are in no way justified and are questionable. The calculation also does not take into account the distribution of the workload of X-ray machines by the tube voltage, the significant attenuation of direct X-ray radiation by additional structures necessary for image acquisition. The values of the radiation output of X-ray machines recommended for shielding design in SanPiN 2.6.1.1192-03 are 2–3 times overestimated in relation to the measured values. This leads to an unreasonable overestimation of the requirements for the thickness of radiation shielding in X-ray rooms and accordingly to suboptimal spending on healthcare. It is necessary to develop a new document to replace SanPiN 2.6.1.1192-03.\",\"PeriodicalId\":496413,\"journal\":{\"name\":\"Радиационная гигиена\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Радиационная гигиена\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21514/1998-426x-2023-16-3-13-21\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Радиационная гигиена","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21514/1998-426x-2023-16-3-13-21","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文论证了三品2.6.1.1192-03中提出的现有x射线室辐射屏蔽计算方法的局限性。结果表明,用障壁计算衰减系数的算法没有考虑到x射线辐射的不同组分:直接辐射、散射辐射和泄漏辐射的衰减特征,它们在发生区域、强度、能谱等参数上存在差异。相反,对所有分量都使用一个公式,它们的衰减差异是由一个参数来考虑的,该参数对不同的辐射分量的值是不合理的,而且是可疑的。计算也没有考虑到x射线机的工作负荷分布由管电压,直接x射线辐射的显著衰减由额外的结构所需的图像采集。SanPiN 2.6.1.1192-03中推荐用于屏蔽设计的x射线机的辐射输出值相对于实测值高估了2-3倍。这导致对x光室辐射屏蔽厚度要求的不合理高估,从而导致医疗保健支出不理想。有必要制定一个新的文件来代替SanPiN 2.6.1.1192-03。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Critical analysis of the existing approach to the calculation of radiation shielding in X-ray rooms
The paper demonstrates the limitations of the existing methodology for calculating the radiation shielding of X-ray rooms presented in SanPin 2.6.1.1192-03. It is shown that the algorithm for calculating the attenuation coefficient by the barrier does not take into account the features of the attenuation of different components of X-ray radiation: direct, scattered, and leakage radiation, which differ in the region of occurrence, intensity, energy spectrum, and other parameters. Instead, a single formula is used for all components, and the differences in their attenuation are taken into account by a parameter the values of which for different radiation components are in no way justified and are questionable. The calculation also does not take into account the distribution of the workload of X-ray machines by the tube voltage, the significant attenuation of direct X-ray radiation by additional structures necessary for image acquisition. The values of the radiation output of X-ray machines recommended for shielding design in SanPiN 2.6.1.1192-03 are 2–3 times overestimated in relation to the measured values. This leads to an unreasonable overestimation of the requirements for the thickness of radiation shielding in X-ray rooms and accordingly to suboptimal spending on healthcare. It is necessary to develop a new document to replace SanPiN 2.6.1.1192-03.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Russian decision support systems in radiation diagnostics as an element of ensuring the radiation safety of patients Exposure of students (pupils) and employees of educational institutions in the Leningrad region to natural sources of radiation Part 2: Hygienic assessment of doses and health risks depending on methods and approaches to measuring indoor radon concentration Preliminary assessment of <sub>225</sub>Ac excretion in patients undergoing radionuclide therapy with <sub>225</sub>Ac-DOTA-TATE Working conditions and values of average annual effective doses for nondestructive testing operators in the Russian Federation and abroad Results of modern radiation-hygienic surveys of settlements of Bryansk Oblast of the Russian Federation bordering the Republic of Belarus. Part 1: Characteristics of the settlements
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1