包括几何效应在内的抛物线槽集热器性能分析

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY Accounts of Chemical Research Pub Date : 2023-09-27 DOI:10.15282/jmes.17.3.2023.2.0756
Mohamed Abdou Mahran Kasem
{"title":"包括几何效应在内的抛物线槽集热器性能分析","authors":"Mohamed Abdou Mahran Kasem","doi":"10.15282/jmes.17.3.2023.2.0756","DOIUrl":null,"url":null,"abstract":"Parabolic trough collectors (PTCs) have been known for years as one of the leading methods for extracting energy from the sun. In the present work, the performance of PTCs was investigated. However, its performance needs some improvement to be integrated in more and wide range of applications. This idea motivated the author to investigate the performance of parabolic trough collectors in detail. Thus, in the present work, the performance of parabolic trough collectors is investigated. The effect of eight geometric and inlet variables on the PTC performance was evaluated. Two performance factors , the temperature difference and thermal efficiency, were selected. The effect of inlet condition, including inlet mass flow rate and inlet flow temperature reflector geometry, including reflector length and width,receiver diameters, including inlet and outlet reciever diameters, and cover diameters, including the inlet and outlet cover diameters on these PFs was assessed. Eight thermal working fluids were considered. A non-linear mathematical model was developed for PTC and implemented into MATLAB code where an iterative technique was used to conduct the present analyses. Level curves were generated to study the PTC key performance parameters. The curves revealed that the maximum values of the PFs and maximum range of change in these PFs occurred when the inlet conditions were varied. Changes in the inlet temperature, and changes in the reflector geometry yielded the highest and second-highest values. The cover geometry had the minimum effect on the PFs. Moreover, the best maximum efficiency, best maximum temperature difference, and maximum range of efficiency change were obtained for water, air, and carbon dioxide, respectively. The effect of inlet temperature is more significant than the mass flow rate effect on the thermal efficiency, whereas this effect is reversed in case of the temperature difference, by which the mass flow rate exerts the least influence on the temperature difference.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Detailed performance analysis of parabolic trough collectors including geometric effect\",\"authors\":\"Mohamed Abdou Mahran Kasem\",\"doi\":\"10.15282/jmes.17.3.2023.2.0756\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Parabolic trough collectors (PTCs) have been known for years as one of the leading methods for extracting energy from the sun. In the present work, the performance of PTCs was investigated. However, its performance needs some improvement to be integrated in more and wide range of applications. This idea motivated the author to investigate the performance of parabolic trough collectors in detail. Thus, in the present work, the performance of parabolic trough collectors is investigated. The effect of eight geometric and inlet variables on the PTC performance was evaluated. Two performance factors , the temperature difference and thermal efficiency, were selected. The effect of inlet condition, including inlet mass flow rate and inlet flow temperature reflector geometry, including reflector length and width,receiver diameters, including inlet and outlet reciever diameters, and cover diameters, including the inlet and outlet cover diameters on these PFs was assessed. Eight thermal working fluids were considered. A non-linear mathematical model was developed for PTC and implemented into MATLAB code where an iterative technique was used to conduct the present analyses. Level curves were generated to study the PTC key performance parameters. The curves revealed that the maximum values of the PFs and maximum range of change in these PFs occurred when the inlet conditions were varied. Changes in the inlet temperature, and changes in the reflector geometry yielded the highest and second-highest values. The cover geometry had the minimum effect on the PFs. Moreover, the best maximum efficiency, best maximum temperature difference, and maximum range of efficiency change were obtained for water, air, and carbon dioxide, respectively. The effect of inlet temperature is more significant than the mass flow rate effect on the thermal efficiency, whereas this effect is reversed in case of the temperature difference, by which the mass flow rate exerts the least influence on the temperature difference.\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2023-09-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15282/jmes.17.3.2023.2.0756\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15282/jmes.17.3.2023.2.0756","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

抛物槽集热器(ptc)多年来一直被认为是从太阳中提取能量的主要方法之一。本文对ptc的性能进行了研究。但是,它的性能还有待提高,以便集成到更广泛的应用中。这一想法促使作者对抛物线槽集热器的性能进行了详细的研究。因此,在本工作中,研究了抛物线槽集热器的性能。评估了8个几何变量和入口变量对PTC性能的影响。选取了温差和热效率两个性能因子。评估了进口条件(包括进口质量流量和进口流动温度)、反射镜几何形状(包括反射镜长度和宽度)、接收器直径(包括进口和出口接收器直径)和罩直径(包括进口和出口罩直径)对这些PFs的影响。考虑了八种热工质。建立了PTC的非线性数学模型,并在MATLAB代码中实现,其中使用迭代技术进行了当前的分析。生成水平曲线,研究PTC关键性能参数。从曲线上可以看出,在不同的进口条件下,气流动力因数的最大值和变化范围最大。入口温度的变化和反射器几何形状的变化产生了最高和第二高的值。覆盖物的几何形状对PFs的影响最小。此外,水、空气和二氧化碳分别获得最佳最大效率、最佳最大温差和最大效率变化范围。进口温度对热效率的影响大于质量流量对热效率的影响,而在存在温差的情况下,这种影响是相反的,质量流量对温差的影响最小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Detailed performance analysis of parabolic trough collectors including geometric effect
Parabolic trough collectors (PTCs) have been known for years as one of the leading methods for extracting energy from the sun. In the present work, the performance of PTCs was investigated. However, its performance needs some improvement to be integrated in more and wide range of applications. This idea motivated the author to investigate the performance of parabolic trough collectors in detail. Thus, in the present work, the performance of parabolic trough collectors is investigated. The effect of eight geometric and inlet variables on the PTC performance was evaluated. Two performance factors , the temperature difference and thermal efficiency, were selected. The effect of inlet condition, including inlet mass flow rate and inlet flow temperature reflector geometry, including reflector length and width,receiver diameters, including inlet and outlet reciever diameters, and cover diameters, including the inlet and outlet cover diameters on these PFs was assessed. Eight thermal working fluids were considered. A non-linear mathematical model was developed for PTC and implemented into MATLAB code where an iterative technique was used to conduct the present analyses. Level curves were generated to study the PTC key performance parameters. The curves revealed that the maximum values of the PFs and maximum range of change in these PFs occurred when the inlet conditions were varied. Changes in the inlet temperature, and changes in the reflector geometry yielded the highest and second-highest values. The cover geometry had the minimum effect on the PFs. Moreover, the best maximum efficiency, best maximum temperature difference, and maximum range of efficiency change were obtained for water, air, and carbon dioxide, respectively. The effect of inlet temperature is more significant than the mass flow rate effect on the thermal efficiency, whereas this effect is reversed in case of the temperature difference, by which the mass flow rate exerts the least influence on the temperature difference.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
期刊最新文献
Intentions to move abroad among medical students: a cross-sectional study to investigate determinants and opinions. Analysis of Medical Rehabilitation Needs of 2023 Kahramanmaraş Earthquake Victims: Adıyaman Example. Efficacy of whole body vibration on fascicle length and joint angle in children with hemiplegic cerebral palsy. The change process questionnaire (CPQ): A psychometric validation. Prevalence and predictors of hand hygiene compliance in clinical, surgical and intensive care unit wards: results of a second cross-sectional study at the Umberto I teaching hospital of Rome.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1