传统民居清真寺室内热条件评价——以马来西亚甘榜劳清真寺为例

IF 0.6 Q3 ENGINEERING, MULTIDISCIPLINARY Jurnal Kejuruteraan Pub Date : 2023-05-30 DOI:10.17576/jkukm-2023-35(3)-12
Nur Athirah binti Khalit, Zuraini binti Denan, Aliyah Nur Zafirah binti Sanusi, Norwina binti Mohd Nawawi
{"title":"传统民居清真寺室内热条件评价——以马来西亚甘榜劳清真寺为例","authors":"Nur Athirah binti Khalit, Zuraini binti Denan, Aliyah Nur Zafirah binti Sanusi, Norwina binti Mohd Nawawi","doi":"10.17576/jkukm-2023-35(3)-12","DOIUrl":null,"url":null,"abstract":"Traditional vernacular architectures in Malaysia include public buildings such as a masjid were designed with the tropical climate in mind and have proven to be an excellent example of providing indoor thermal comfort to the occupants. It is a naturally ventilated building being greatly influenced by the building designs. In traditional vernacular architecture, the roof is the main building enclosure that contributes to the total heat gain. Hence, the research aims to assess the indoor thermal condition of Masjid Kampung Laut, Kelantan, the first traditional vernacular masjid in Malaysia. Data were collected using the method of field measurement to evaluate the indoor comfort level of the masjid, in terms of indoor air temperature, air velocity, and relative humidity. The results demonstrate that the average indoor air temperature is acceptable and Masjid Kampung Laut responded favorably to the local climate. However, it is believed that with an increase of 0.4m/s to 1.2m/s of air movement, will further enhance indoor thermal comfort. Therefore, the findings can guide further thermal comfort prediction studies for other naturally ventilated buildings. Several other potential passive design strategies for roof design are proposed in this study to achieve acceptable indoor thermal comfort conditions for the masjid in Malaysia.","PeriodicalId":17688,"journal":{"name":"Jurnal Kejuruteraan","volume":"8 1","pages":"0"},"PeriodicalIF":0.6000,"publicationDate":"2023-05-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of Indoor Thermal Condition on Traditional Vernacular Masjid: A Case Study on Masjid Kampung Laut, Malaysia\",\"authors\":\"Nur Athirah binti Khalit, Zuraini binti Denan, Aliyah Nur Zafirah binti Sanusi, Norwina binti Mohd Nawawi\",\"doi\":\"10.17576/jkukm-2023-35(3)-12\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Traditional vernacular architectures in Malaysia include public buildings such as a masjid were designed with the tropical climate in mind and have proven to be an excellent example of providing indoor thermal comfort to the occupants. It is a naturally ventilated building being greatly influenced by the building designs. In traditional vernacular architecture, the roof is the main building enclosure that contributes to the total heat gain. Hence, the research aims to assess the indoor thermal condition of Masjid Kampung Laut, Kelantan, the first traditional vernacular masjid in Malaysia. Data were collected using the method of field measurement to evaluate the indoor comfort level of the masjid, in terms of indoor air temperature, air velocity, and relative humidity. The results demonstrate that the average indoor air temperature is acceptable and Masjid Kampung Laut responded favorably to the local climate. However, it is believed that with an increase of 0.4m/s to 1.2m/s of air movement, will further enhance indoor thermal comfort. Therefore, the findings can guide further thermal comfort prediction studies for other naturally ventilated buildings. Several other potential passive design strategies for roof design are proposed in this study to achieve acceptable indoor thermal comfort conditions for the masjid in Malaysia.\",\"PeriodicalId\":17688,\"journal\":{\"name\":\"Jurnal Kejuruteraan\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2023-05-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Kejuruteraan\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17576/jkukm-2023-35(3)-12\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Kejuruteraan","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17576/jkukm-2023-35(3)-12","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

马来西亚的传统乡土建筑包括公共建筑,如清真寺,在设计时考虑到热带气候,并已被证明是为居住者提供室内热舒适的一个很好的例子。它是一个自然通风的建筑,受建筑设计的影响很大。在传统的乡土建筑中,屋顶是主要的建筑围护结构,有助于获得总热量。因此,本研究旨在评估马来西亚第一座传统民居清真寺吉兰丹甘榜劳清真寺(Masjid Kampung Laut)的室内热状况。采用现场测量的方法收集数据,从室内空气温度、风速和相对湿度等方面评价清真寺的室内舒适度。结果表明,平均室内温度是可以接受的,甘榜劳清真寺对当地气候有良好的反应。但是,相信随着0.4m/s到1.2m/s的空气移动,将进一步增强室内热舒适性。因此,研究结果可以指导其他自然通风建筑的热舒适预测研究。本研究提出了其他几种潜在的被动式屋顶设计策略,以实现马来西亚清真寺可接受的室内热舒适条件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Assessment of Indoor Thermal Condition on Traditional Vernacular Masjid: A Case Study on Masjid Kampung Laut, Malaysia
Traditional vernacular architectures in Malaysia include public buildings such as a masjid were designed with the tropical climate in mind and have proven to be an excellent example of providing indoor thermal comfort to the occupants. It is a naturally ventilated building being greatly influenced by the building designs. In traditional vernacular architecture, the roof is the main building enclosure that contributes to the total heat gain. Hence, the research aims to assess the indoor thermal condition of Masjid Kampung Laut, Kelantan, the first traditional vernacular masjid in Malaysia. Data were collected using the method of field measurement to evaluate the indoor comfort level of the masjid, in terms of indoor air temperature, air velocity, and relative humidity. The results demonstrate that the average indoor air temperature is acceptable and Masjid Kampung Laut responded favorably to the local climate. However, it is believed that with an increase of 0.4m/s to 1.2m/s of air movement, will further enhance indoor thermal comfort. Therefore, the findings can guide further thermal comfort prediction studies for other naturally ventilated buildings. Several other potential passive design strategies for roof design are proposed in this study to achieve acceptable indoor thermal comfort conditions for the masjid in Malaysia.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Jurnal Kejuruteraan
Jurnal Kejuruteraan ENGINEERING, MULTIDISCIPLINARY-
自引率
16.70%
发文量
0
审稿时长
24 weeks
期刊最新文献
3D Printed Carbon Fibre Reinforced Polyamides in High Temperature An App for Parking with Indoor Navigation Facility Numerical Analysis of Structural Batteries Response with the Presence of Uncertainty Experimental Investigation of Mechanical and Microstructural Properties of Concrete Containing Bentonite and Dolomite as a Partial Replacement of Cement The Design of Stroke Rehabilitation Using Artificial Intelligence K.A.K.I (Kinesthetic Augmented Kinematic Inference)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1