土坝动力学研究:探讨内防渗岩心和趾部排水孔布置对快速落水情景下渗流和安全系数的影响

IF 2.7 Q2 CONSTRUCTION & BUILDING TECHNOLOGY Infrastructures Pub Date : 2023-10-12 DOI:10.3390/infrastructures8100148
Yelbek Bakhitovich Utepov, Timoth Mkilima, Aliya Kairatovna Aldungarova, Zhanbolat Anuarbekovich Shakhmov, Sungat Berkinovich Akhazhanov, Nargul Amanovna Saktaganova, Uliya Baktybaevna Abdikerova, Aigul Moldashevna Budikova
{"title":"土坝动力学研究:探讨内防渗岩心和趾部排水孔布置对快速落水情景下渗流和安全系数的影响","authors":"Yelbek Bakhitovich Utepov, Timoth Mkilima, Aliya Kairatovna Aldungarova, Zhanbolat Anuarbekovich Shakhmov, Sungat Berkinovich Akhazhanov, Nargul Amanovna Saktaganova, Uliya Baktybaevna Abdikerova, Aigul Moldashevna Budikova","doi":"10.3390/infrastructures8100148","DOIUrl":null,"url":null,"abstract":"The study examined the intricate relationships between embankment slope configurations, toe drain designs, and drawdown scenarios. It utilized a unique combination of numerical, physical, and mathematical models. The investigation involved 16 numerical models and 8 physical models with distinct characteristics. The research explored the correlations of key parameters: matric suction, horizontal water conductivity, time, and factor of safety. The factor of safety values varied from 0.62 to 1.03 as a result of the different investigated combinations. For instance, a 1:2 embankment slope without a toe drain under instantaneous drawdown led to the factor of safety values ranging from 1.22 to 1.57. Additionally, incorporating elements like a 30 m toe drain and a 1 m per day drawdown rate influenced these values, with extremes recorded from 1.337 to 2.21, shedding light on embankment stability under diverse conditions and configurations. When subjected to a 1 m per day drawdown, water flow rates decreased significantly at the upstream face and increased downstream, accompanied by an increase in water mass flux at the upstream face and a decrease at the downstream toe, suggesting dynamic changes in water behavior in response to drawdown. Moreover, the findings unveiled significant correlations between matric suction and time (correlation coefficient of 0.950) and factor of safety and water conductivity (correlation coefficient of 0.750). Conversely, a distinct negative correlation emerged between matric suction and factor of safety (correlation coefficient of −0.864). The study’s distinctive insights contribute to our understanding of seepage behavior and dam stability across varied scenarios, offering valuable input for resilient dam construction approaches that will ensure the longevity and effectiveness of these essential structures.","PeriodicalId":13601,"journal":{"name":"Infrastructures","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2023-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Delving into Earth Dam Dynamics: Exploring the Impact of Inner Impervious Core and Toe Drain Arrangement on Seepage and Factor of Safety during Rapid Drawdown Scenarios\",\"authors\":\"Yelbek Bakhitovich Utepov, Timoth Mkilima, Aliya Kairatovna Aldungarova, Zhanbolat Anuarbekovich Shakhmov, Sungat Berkinovich Akhazhanov, Nargul Amanovna Saktaganova, Uliya Baktybaevna Abdikerova, Aigul Moldashevna Budikova\",\"doi\":\"10.3390/infrastructures8100148\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The study examined the intricate relationships between embankment slope configurations, toe drain designs, and drawdown scenarios. It utilized a unique combination of numerical, physical, and mathematical models. The investigation involved 16 numerical models and 8 physical models with distinct characteristics. The research explored the correlations of key parameters: matric suction, horizontal water conductivity, time, and factor of safety. The factor of safety values varied from 0.62 to 1.03 as a result of the different investigated combinations. For instance, a 1:2 embankment slope without a toe drain under instantaneous drawdown led to the factor of safety values ranging from 1.22 to 1.57. Additionally, incorporating elements like a 30 m toe drain and a 1 m per day drawdown rate influenced these values, with extremes recorded from 1.337 to 2.21, shedding light on embankment stability under diverse conditions and configurations. When subjected to a 1 m per day drawdown, water flow rates decreased significantly at the upstream face and increased downstream, accompanied by an increase in water mass flux at the upstream face and a decrease at the downstream toe, suggesting dynamic changes in water behavior in response to drawdown. Moreover, the findings unveiled significant correlations between matric suction and time (correlation coefficient of 0.950) and factor of safety and water conductivity (correlation coefficient of 0.750). Conversely, a distinct negative correlation emerged between matric suction and factor of safety (correlation coefficient of −0.864). The study’s distinctive insights contribute to our understanding of seepage behavior and dam stability across varied scenarios, offering valuable input for resilient dam construction approaches that will ensure the longevity and effectiveness of these essential structures.\",\"PeriodicalId\":13601,\"journal\":{\"name\":\"Infrastructures\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2023-10-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Infrastructures\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/infrastructures8100148\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Infrastructures","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/infrastructures8100148","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

该研究检查了路堤坡度配置,脚趾排水设计和下降情景之间的复杂关系。它利用了数值、物理和数学模型的独特组合。研究涉及16个数值模型和8个具有不同特征的物理模型。研究探讨了关键参数:基质吸力、水平水电导率、时间和安全系数的相关性。由于不同的研究组合,安全系数从0.62到1.03不等。例如,在瞬时下拉条件下,1:2路堤坡面不设坡脚排水,其安全系数为1.22 ~ 1.57。此外,考虑到30米的趾部排水和每天1米的下降率等因素,这些值的极值从1.337到2.21不等,揭示了不同条件和配置下路堤的稳定性。当每天降压1 m时,上游水流速率显著降低,下游水流速率显著增加,同时上游水流通量增加,下游水流通量减少,表明水的动态变化是对降压的响应。此外,基质吸力与时间(相关系数为0.950)、安全系数与水电导率(相关系数为0.750)之间存在显著相关性。相反,基质吸力与安全系数呈显著负相关(相关系数为- 0.864)。该研究的独特见解有助于我们理解各种情况下的渗流行为和大坝稳定性,为弹性大坝建设方法提供宝贵的投入,这些方法将确保这些重要结构的寿命和有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Delving into Earth Dam Dynamics: Exploring the Impact of Inner Impervious Core and Toe Drain Arrangement on Seepage and Factor of Safety during Rapid Drawdown Scenarios
The study examined the intricate relationships between embankment slope configurations, toe drain designs, and drawdown scenarios. It utilized a unique combination of numerical, physical, and mathematical models. The investigation involved 16 numerical models and 8 physical models with distinct characteristics. The research explored the correlations of key parameters: matric suction, horizontal water conductivity, time, and factor of safety. The factor of safety values varied from 0.62 to 1.03 as a result of the different investigated combinations. For instance, a 1:2 embankment slope without a toe drain under instantaneous drawdown led to the factor of safety values ranging from 1.22 to 1.57. Additionally, incorporating elements like a 30 m toe drain and a 1 m per day drawdown rate influenced these values, with extremes recorded from 1.337 to 2.21, shedding light on embankment stability under diverse conditions and configurations. When subjected to a 1 m per day drawdown, water flow rates decreased significantly at the upstream face and increased downstream, accompanied by an increase in water mass flux at the upstream face and a decrease at the downstream toe, suggesting dynamic changes in water behavior in response to drawdown. Moreover, the findings unveiled significant correlations between matric suction and time (correlation coefficient of 0.950) and factor of safety and water conductivity (correlation coefficient of 0.750). Conversely, a distinct negative correlation emerged between matric suction and factor of safety (correlation coefficient of −0.864). The study’s distinctive insights contribute to our understanding of seepage behavior and dam stability across varied scenarios, offering valuable input for resilient dam construction approaches that will ensure the longevity and effectiveness of these essential structures.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Infrastructures
Infrastructures Engineering-Building and Construction
CiteScore
5.20
自引率
7.70%
发文量
145
审稿时长
11 weeks
期刊最新文献
A Comprehensive Study on Unsupervised Transfer Learning for Structural Health Monitoring of Bridges Using Joint Distribution Adaptation Improving Lightweight Structural Tuff Concrete Composition Using Three-Factor Experimental Planning Buckling Instability of Monopiles in Liquefied Soil via Structural Reliability Assessment Framework Effect of Incorporating Cement and Olive Waste Ash on the Mechanical Properties of Rammed Earth Block Integrating Machine Learning in Geotechnical Engineering: A Novel Approach for Railway Track Layer Design Based on Cone Penetration Test Data
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1