经皮A1滑轮松解术治疗扳机指的严重并发症:病例报告及文献复习

IF 1.3 Q3 SURGERY Archives of Plastic Surgery-APS Pub Date : 2023-09-21 DOI:10.1055/a-2179-3911
Dong Chul Lee, Kyungjin Lee, Ho Hyung Lee
{"title":"经皮A1滑轮松解术治疗扳机指的严重并发症:病例报告及文献复习","authors":"Dong Chul Lee, Kyungjin Lee, Ho Hyung Lee","doi":"10.1055/a-2179-3911","DOIUrl":null,"url":null,"abstract":"Percutaneous A1 pulley release, which has been increasingly used to treat trigger fingers, has been widely established as a safe and simple procedure. Multiple studies have reported positive results of percutaneous A1 pulley release. In this study, however, we report cases of patients who developed complications after undergoing percutaneous A1 pulley release at local clinics. A total of six patients visited our hospital for infectious complications after percutaneous A1 pulley release. Various sequelae such as damage to normal structures, insufficient procedure, and tissue necrosis were observed during the exploration. A retrospective study was conducted to identify the cause and trend of the observed complications by instruments (HAKI knife or needle) etc. In the HAKI knife group, there was a tendency for damage to normal structures, while in the needle group, an insufficient release or serious soft tissue necrosis was observed. Based on these cases, our findings confirm the existence and characteristics of infectious complications following the percutaneous A1 pulley release. We further identify that the type of instrument used predicts the nature of complications. Thus, reliable and skilled performance of the procedure by experts is essential for safe treatment.","PeriodicalId":47543,"journal":{"name":"Archives of Plastic Surgery-APS","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2023-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Serious Complications of Percutaneous A1 pulley release for trigger finger: Case reports and literature review\",\"authors\":\"Dong Chul Lee, Kyungjin Lee, Ho Hyung Lee\",\"doi\":\"10.1055/a-2179-3911\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Percutaneous A1 pulley release, which has been increasingly used to treat trigger fingers, has been widely established as a safe and simple procedure. Multiple studies have reported positive results of percutaneous A1 pulley release. In this study, however, we report cases of patients who developed complications after undergoing percutaneous A1 pulley release at local clinics. A total of six patients visited our hospital for infectious complications after percutaneous A1 pulley release. Various sequelae such as damage to normal structures, insufficient procedure, and tissue necrosis were observed during the exploration. A retrospective study was conducted to identify the cause and trend of the observed complications by instruments (HAKI knife or needle) etc. In the HAKI knife group, there was a tendency for damage to normal structures, while in the needle group, an insufficient release or serious soft tissue necrosis was observed. Based on these cases, our findings confirm the existence and characteristics of infectious complications following the percutaneous A1 pulley release. We further identify that the type of instrument used predicts the nature of complications. Thus, reliable and skilled performance of the procedure by experts is essential for safe treatment.\",\"PeriodicalId\":47543,\"journal\":{\"name\":\"Archives of Plastic Surgery-APS\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2023-09-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archives of Plastic Surgery-APS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/a-2179-3911\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Plastic Surgery-APS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/a-2179-3911","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

经皮A1滑轮松解术越来越多地用于治疗扳机指,已被广泛认为是一种安全、简单的手术。多项研究报道了经皮A1滑轮释放的阳性结果。然而,在本研究中,我们报告了在当地诊所接受经皮A1滑轮释放后出现并发症的病例。共有6例患者因经皮A1滑轮松解术后的感染并发症来我院就诊。在探查过程中观察到各种后遗症,如正常结构损伤、手术不充分和组织坏死。回顾性分析手术器械(HAKI刀或HAKI针)并发症发生的原因及趋势。HAKI刀组有损伤正常结构的倾向,而针刺组则有松动不充分或软组织严重坏死的情况。基于这些病例,我们的研究结果证实了经皮A1滑轮松解术后感染性并发症的存在及其特点。我们进一步确定所使用的器械类型可以预测并发症的性质。因此,由专家可靠和熟练地执行该程序对于安全治疗至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Serious Complications of Percutaneous A1 pulley release for trigger finger: Case reports and literature review
Percutaneous A1 pulley release, which has been increasingly used to treat trigger fingers, has been widely established as a safe and simple procedure. Multiple studies have reported positive results of percutaneous A1 pulley release. In this study, however, we report cases of patients who developed complications after undergoing percutaneous A1 pulley release at local clinics. A total of six patients visited our hospital for infectious complications after percutaneous A1 pulley release. Various sequelae such as damage to normal structures, insufficient procedure, and tissue necrosis were observed during the exploration. A retrospective study was conducted to identify the cause and trend of the observed complications by instruments (HAKI knife or needle) etc. In the HAKI knife group, there was a tendency for damage to normal structures, while in the needle group, an insufficient release or serious soft tissue necrosis was observed. Based on these cases, our findings confirm the existence and characteristics of infectious complications following the percutaneous A1 pulley release. We further identify that the type of instrument used predicts the nature of complications. Thus, reliable and skilled performance of the procedure by experts is essential for safe treatment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.10
自引率
6.70%
发文量
131
审稿时长
10 weeks
期刊最新文献
Minilifting: Short-Scar Rhytidectomy with Thread Lifting. The Old and the New-An Ellege. Distally Based Lymphatic Microsurgical Preventive Healing Approach-A Modification of the Classic Approach. Safety and Effectiveness of Liposuction Modalities in Managing Lipedema: Systematic Review and Meta-analysis. "Funducation"-The New Age of Learning, Intersection of Education, and Fun.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1