CT检查对患者放射剂量和癌症风险的评估。

IF 1.7 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Radiological Physics and Technology Pub Date : 2024-03-01 Epub Date: 2023-12-04 DOI:10.1007/s12194-023-00763-w
Saowapark Poosiri, Anchali Krisanachinda, Kitiwat Khamwan
{"title":"CT检查对患者放射剂量和癌症风险的评估。","authors":"Saowapark Poosiri, Anchali Krisanachinda, Kitiwat Khamwan","doi":"10.1007/s12194-023-00763-w","DOIUrl":null,"url":null,"abstract":"<p><p>Computed tomography (CT) examinations have been increasingly requested and become the major sources of patient exposure. The cancer risk from CT scans is contingent upon the amount of absorbed dose of organs. This study aims to determine the organ doses and risk of cancer incidence and mortality from CT examinations at high dose (cumulative effective dose, CED ≥ 100 mSv) in a single day to low dose (CED < 100 mSv) from common CT procedures. Data were gathered from two academic centers of patients aged 15 to 75 years old performed CT examinations during the period of 5 years. CED and organ dose were calculated using Monte Carlo simulation software. Lifetime attributable risk (LAR) was determined following Biological Effects of Ionizing Radiation (BEIR) VII report based on life table and baseline cancer rates of Thai population. At high dose, the highest LAR for breast cancer incidence in young female was 82 per 100,000 exposed patients with breast dose of 148 mGy (CT whole abdomen). The highest LAR for liver cancer incidence in male patient was 72 per 100,000 with liver dose of 133 mGy (multiple CT scans). At low dose, the highest average LAR for breast cancer incidence in young female was 23 per 100,000 while for liver cancer incidence in male patients was 22 per 100,000 (CTA whole aorta). Even though the LAR of cancer incidence and mortality was less than 100 per 100,000, they should not be neglected. The risk of cancer incidence may be increased in later life, particularly in young patients.</p>","PeriodicalId":46252,"journal":{"name":"Radiological Physics and Technology","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of patient radiation dose and risk of cancer from CT examinations.\",\"authors\":\"Saowapark Poosiri, Anchali Krisanachinda, Kitiwat Khamwan\",\"doi\":\"10.1007/s12194-023-00763-w\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Computed tomography (CT) examinations have been increasingly requested and become the major sources of patient exposure. The cancer risk from CT scans is contingent upon the amount of absorbed dose of organs. This study aims to determine the organ doses and risk of cancer incidence and mortality from CT examinations at high dose (cumulative effective dose, CED ≥ 100 mSv) in a single day to low dose (CED < 100 mSv) from common CT procedures. Data were gathered from two academic centers of patients aged 15 to 75 years old performed CT examinations during the period of 5 years. CED and organ dose were calculated using Monte Carlo simulation software. Lifetime attributable risk (LAR) was determined following Biological Effects of Ionizing Radiation (BEIR) VII report based on life table and baseline cancer rates of Thai population. At high dose, the highest LAR for breast cancer incidence in young female was 82 per 100,000 exposed patients with breast dose of 148 mGy (CT whole abdomen). The highest LAR for liver cancer incidence in male patient was 72 per 100,000 with liver dose of 133 mGy (multiple CT scans). At low dose, the highest average LAR for breast cancer incidence in young female was 23 per 100,000 while for liver cancer incidence in male patients was 22 per 100,000 (CTA whole aorta). Even though the LAR of cancer incidence and mortality was less than 100 per 100,000, they should not be neglected. The risk of cancer incidence may be increased in later life, particularly in young patients.</p>\",\"PeriodicalId\":46252,\"journal\":{\"name\":\"Radiological Physics and Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiological Physics and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s12194-023-00763-w\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/12/4 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiological Physics and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s12194-023-00763-w","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/4 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

计算机断层扫描(CT)检查的需求日益增加,并成为患者暴露的主要来源。CT扫描的癌症风险取决于器官吸收剂量的大小。本研究旨在确定高剂量(累积有效剂量,CED≥100 mSv)和低剂量(CED)下的器官剂量、癌症发病率和死亡率
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of patient radiation dose and risk of cancer from CT examinations.

Computed tomography (CT) examinations have been increasingly requested and become the major sources of patient exposure. The cancer risk from CT scans is contingent upon the amount of absorbed dose of organs. This study aims to determine the organ doses and risk of cancer incidence and mortality from CT examinations at high dose (cumulative effective dose, CED ≥ 100 mSv) in a single day to low dose (CED < 100 mSv) from common CT procedures. Data were gathered from two academic centers of patients aged 15 to 75 years old performed CT examinations during the period of 5 years. CED and organ dose were calculated using Monte Carlo simulation software. Lifetime attributable risk (LAR) was determined following Biological Effects of Ionizing Radiation (BEIR) VII report based on life table and baseline cancer rates of Thai population. At high dose, the highest LAR for breast cancer incidence in young female was 82 per 100,000 exposed patients with breast dose of 148 mGy (CT whole abdomen). The highest LAR for liver cancer incidence in male patient was 72 per 100,000 with liver dose of 133 mGy (multiple CT scans). At low dose, the highest average LAR for breast cancer incidence in young female was 23 per 100,000 while for liver cancer incidence in male patients was 22 per 100,000 (CTA whole aorta). Even though the LAR of cancer incidence and mortality was less than 100 per 100,000, they should not be neglected. The risk of cancer incidence may be increased in later life, particularly in young patients.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Radiological Physics and Technology
Radiological Physics and Technology RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
3.00
自引率
12.50%
发文量
40
期刊介绍: The purpose of the journal Radiological Physics and Technology is to provide a forum for sharing new knowledge related to research and development in radiological science and technology, including medical physics and radiological technology in diagnostic radiology, nuclear medicine, and radiation therapy among many other radiological disciplines, as well as to contribute to progress and improvement in medical practice and patient health care.
期刊最新文献
Optimum delineation of skin structure for dose calculation with the linear Boltzmann transport equation algorithm in radiotherapy treatment planning. Parameter optimisation for image acquisition and stacking in carbon dioxide digital subtraction angiography. Estimation of the lateral variation of photon beam energy spectra using the percentage depth dose reconstruction method. Joint segmentation of sternocleidomastoid and skeletal muscles in computed tomography images using a multiclass learning approach. Correction: Recommendation for reducing the crystalline lens exposure dose by reducing imaging field width in cone-beam computed tomography for image-guided radiation therapy: an anthropomorphic phantom study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1