{"title":"多峰发光二极管固化单元及3d打印冠桥树脂的聚合。","authors":"S H Chung, E-S Jiang, B-S Lim, S-H Kim, J Chang","doi":"10.2341/23-061-L","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to evaluate the substitutive and additive efficacy of multi-peak light-emitting diode (LED) curing units for post-curing of a three-dimensional- (3D-) printed crown and bridge resin.</p><p><strong>Methods: </strong>A total of 792 disc- and 180 bar-shaped specimens were printed with a crown and bridge resin (NextDent C&B MFH) and post-cured using two LED curing units (VALO Cordless and Bluephase N G4) in fast and standard modes. Conventional post-curing (LC-3D Print Box, Group PC) was compared with LED-only curing (Groups V1, V2, B1, and B2) and LED-combined curing (Groups PV1, PV2, PB1, and PB2) in terms of microhardness, flexural strength, degree of conversion (DC), and CIE L*a*b* color and translucency parameters. Cytotoxicity of the resin eluates was evaluated using the WST-1 assay. Temperature increases on the resin surface were measured with infrared thermography. Data were statistically analyzed using ANOVA and Kruskal-Wallis tests (α=0.05).</p><p><strong>Results: </strong>The microhardness and flexural strength in Groups V1, V2, B1, and DC in all LED-only groups were lower than in other groups (p<0.05). Larger color disparities existed between Group PC and all LED-only groups than between Group PC and the others (p<0.05). There was no significant difference in cytotoxicity among the groups. The temperature increase was lowest in Groups V1 and PV1 during light curing (p<0.05).</p><p><strong>Conclusions: </strong>Post-curing by multi-peak LED curing units was not as effective as the conventional post-curing device. Additional post-curing by LED curing units did not improve the material properties.</p>","PeriodicalId":19502,"journal":{"name":"Operative dentistry","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Multi-peak Light-emitting Diode Curing Units and Polymerization of 3D-printed Crown and Bridge Resin.\",\"authors\":\"S H Chung, E-S Jiang, B-S Lim, S-H Kim, J Chang\",\"doi\":\"10.2341/23-061-L\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study aimed to evaluate the substitutive and additive efficacy of multi-peak light-emitting diode (LED) curing units for post-curing of a three-dimensional- (3D-) printed crown and bridge resin.</p><p><strong>Methods: </strong>A total of 792 disc- and 180 bar-shaped specimens were printed with a crown and bridge resin (NextDent C&B MFH) and post-cured using two LED curing units (VALO Cordless and Bluephase N G4) in fast and standard modes. Conventional post-curing (LC-3D Print Box, Group PC) was compared with LED-only curing (Groups V1, V2, B1, and B2) and LED-combined curing (Groups PV1, PV2, PB1, and PB2) in terms of microhardness, flexural strength, degree of conversion (DC), and CIE L*a*b* color and translucency parameters. Cytotoxicity of the resin eluates was evaluated using the WST-1 assay. Temperature increases on the resin surface were measured with infrared thermography. Data were statistically analyzed using ANOVA and Kruskal-Wallis tests (α=0.05).</p><p><strong>Results: </strong>The microhardness and flexural strength in Groups V1, V2, B1, and DC in all LED-only groups were lower than in other groups (p<0.05). Larger color disparities existed between Group PC and all LED-only groups than between Group PC and the others (p<0.05). There was no significant difference in cytotoxicity among the groups. The temperature increase was lowest in Groups V1 and PV1 during light curing (p<0.05).</p><p><strong>Conclusions: </strong>Post-curing by multi-peak LED curing units was not as effective as the conventional post-curing device. Additional post-curing by LED curing units did not improve the material properties.</p>\",\"PeriodicalId\":19502,\"journal\":{\"name\":\"Operative dentistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Operative dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2341/23-061-L\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Operative dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2341/23-061-L","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在评价多峰发光二极管(LED)固化单元在三维(3D)打印冠桥树脂后固化中的替代和加性效果。方法:用冠桥树脂(NextDent C&B MFH)打印792个圆盘形和180个条形标本,并使用两个LED固化装置(VALO Cordless和Bluephase N G4)在快速和标准模式下进行后固化。将常规后固化(LC-3D Print Box, PC组)与纯led固化(V1、V2、B1和B2组)和led复合固化(PV1、PV2、PB1和PB2组)在显微硬度、抗弯强度、转换度(DC)、CIE L*a*b*颜色和半透明参数方面进行比较。采用WST-1法评价树脂洗脱液的细胞毒性。用红外热像仪测量了树脂表面的温升。资料采用方差分析和Kruskal-Wallis检验进行统计学分析(α=0.05)。结果:纯LED组V1、V2、B1和DC组的显微硬度和抗弯强度均低于其他组(p结论:采用多峰LED后固化装置后固化效果不如常规后固化装置。LED固化单元的额外后固化并没有改善材料的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Multi-peak Light-emitting Diode Curing Units and Polymerization of 3D-printed Crown and Bridge Resin.

Purpose: This study aimed to evaluate the substitutive and additive efficacy of multi-peak light-emitting diode (LED) curing units for post-curing of a three-dimensional- (3D-) printed crown and bridge resin.

Methods: A total of 792 disc- and 180 bar-shaped specimens were printed with a crown and bridge resin (NextDent C&B MFH) and post-cured using two LED curing units (VALO Cordless and Bluephase N G4) in fast and standard modes. Conventional post-curing (LC-3D Print Box, Group PC) was compared with LED-only curing (Groups V1, V2, B1, and B2) and LED-combined curing (Groups PV1, PV2, PB1, and PB2) in terms of microhardness, flexural strength, degree of conversion (DC), and CIE L*a*b* color and translucency parameters. Cytotoxicity of the resin eluates was evaluated using the WST-1 assay. Temperature increases on the resin surface were measured with infrared thermography. Data were statistically analyzed using ANOVA and Kruskal-Wallis tests (α=0.05).

Results: The microhardness and flexural strength in Groups V1, V2, B1, and DC in all LED-only groups were lower than in other groups (p<0.05). Larger color disparities existed between Group PC and all LED-only groups than between Group PC and the others (p<0.05). There was no significant difference in cytotoxicity among the groups. The temperature increase was lowest in Groups V1 and PV1 during light curing (p<0.05).

Conclusions: Post-curing by multi-peak LED curing units was not as effective as the conventional post-curing device. Additional post-curing by LED curing units did not improve the material properties.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Operative dentistry
Operative dentistry 医学-牙科与口腔外科
CiteScore
4.00
自引率
9.10%
发文量
124
审稿时长
6-12 weeks
期刊介绍: Operative Dentistry is a refereed, international journal published bi-monthly and distributed to subscribers in over 50 countries. In 2012, we printed 84 articles (672 pages). Papers were submitted by authors from 45 countries, in the categories of Clinical Research, Laboratory Research, Clinical Techniques/Case Presentations and Invited Papers, as well as Editorials and Abstracts. One of the strong points of our journal is that our current publication time for accepted manuscripts is 4 to 6 months from the date of submission. Clinical Techniques/Case Presentations have a very quick turnaround time, which allows for very rapid publication of clinical based concepts. We also provide color for those papers that would benefit from its use. The journal does not accept any advertising but you will find postings for faculty positions. Additionally, the journal also does not rent, sell or otherwise allow its subscriber list to be used by any other entity
期刊最新文献
Influence of Battery Levels in Cordless LED Light-curing Units on Properties of Resin Cement and Glass Fiber Post Retention. Effect of Bleaching Treatments on the Mechanical Properties of the Dentin Matrix and on Collagen Biodegradation by Endogenous Protease. Effect of Radiotherapy on the Adhesive Interface of Caries-affected Dentin and Bioactive Restorations: A Micro-CT Analysis. Effect of Surface Treatment with Zirconium Dioxide Slurry on the Bond Strength of Resin Cement to Ultratranslucent Zirconia. Flexural Properties, Wear Resistance, and Microstructural Analysis of Highly Filled Flowable Resin Composites.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1