组织多普勒与常规参数诊断填塞性心包积液:三级转诊中心的横断面研究

IF 0.5 Q4 PEDIATRICS Egyptian Pediatric Association Gazette Pub Date : 2023-12-04 DOI:10.1186/s43054-023-00234-2
Ahmed Behairy, Amira Esmat El Tantawy, Asmaa Mahmoud Hamed, Antoine AbdelMassih, Sara Tarek
{"title":"组织多普勒与常规参数诊断填塞性心包积液:三级转诊中心的横断面研究","authors":"Ahmed Behairy, Amira Esmat El Tantawy, Asmaa Mahmoud Hamed, Antoine AbdelMassih, Sara Tarek","doi":"10.1186/s43054-023-00234-2","DOIUrl":null,"url":null,"abstract":"Conventional signs of tamponade include right ventricular and atrial collapse and respiratory variation in mitral inflow velocities. Despite being reliable, they are qualitative in nature and are not well correlated with clinical signs of deterioration or improvement. Tamponade is invariably preceded and associated with diastolic dysfunction, and tissue Doppler imaging (TDI) can help in early detection of it, earlier than conventional signs. For this purpose, 36 patients presenting with pericardial effusion have been subjected to echocardiography, including effusion dimensions, presence or absence of routine signs of tamponade and TDI-derived LV and RV E/E′ ratios, as well as clinical signs of tamponade to test the diagnostic accuracy of echocardiographic parameters against them. Right atrial and ventricular collapse were the least accurate in the detection of tamponade, while effusion dimension > 14 mm was the most accurate among conventional parameters to point toward tamponade. RV and LV diastolic dysfunction as evidenced by E/E′ ratio showed 100% sensitivity in predicting tamponade, while LV E/E′ ratio showed the highest specificity (100%) in the same context. The higher diagnostic accuracy of LV E/E′ ratio might be also related to the presence of chronic kidney disease patients, with an already jeopardized LV function. TDI technology is now available in most of the portable echocardiography machines and can serve as part of point-of-care echocardiography in the early detection of cardiac tamponade and in decision making for pericardiocentesis. Larger studies can help in consolidating the impression driven from our small-scale cross-sectional study.","PeriodicalId":43064,"journal":{"name":"Egyptian Pediatric Association Gazette","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2023-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Tissue Doppler vs. conventional parameters for diagnosis of tamponading pericardial effusion: a cross-sectional study in tertiary referral center\",\"authors\":\"Ahmed Behairy, Amira Esmat El Tantawy, Asmaa Mahmoud Hamed, Antoine AbdelMassih, Sara Tarek\",\"doi\":\"10.1186/s43054-023-00234-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Conventional signs of tamponade include right ventricular and atrial collapse and respiratory variation in mitral inflow velocities. Despite being reliable, they are qualitative in nature and are not well correlated with clinical signs of deterioration or improvement. Tamponade is invariably preceded and associated with diastolic dysfunction, and tissue Doppler imaging (TDI) can help in early detection of it, earlier than conventional signs. For this purpose, 36 patients presenting with pericardial effusion have been subjected to echocardiography, including effusion dimensions, presence or absence of routine signs of tamponade and TDI-derived LV and RV E/E′ ratios, as well as clinical signs of tamponade to test the diagnostic accuracy of echocardiographic parameters against them. Right atrial and ventricular collapse were the least accurate in the detection of tamponade, while effusion dimension > 14 mm was the most accurate among conventional parameters to point toward tamponade. RV and LV diastolic dysfunction as evidenced by E/E′ ratio showed 100% sensitivity in predicting tamponade, while LV E/E′ ratio showed the highest specificity (100%) in the same context. The higher diagnostic accuracy of LV E/E′ ratio might be also related to the presence of chronic kidney disease patients, with an already jeopardized LV function. TDI technology is now available in most of the portable echocardiography machines and can serve as part of point-of-care echocardiography in the early detection of cardiac tamponade and in decision making for pericardiocentesis. Larger studies can help in consolidating the impression driven from our small-scale cross-sectional study.\",\"PeriodicalId\":43064,\"journal\":{\"name\":\"Egyptian Pediatric Association Gazette\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2023-12-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Egyptian Pediatric Association Gazette\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s43054-023-00234-2\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PEDIATRICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Egyptian Pediatric Association Gazette","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s43054-023-00234-2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PEDIATRICS","Score":null,"Total":0}
引用次数: 0

摘要

传统的心包填塞症状包括右心室和心房塌陷以及二尖瓣流入速度的呼吸变化。尽管是可靠的,但它们本质上是定性的,与临床症状的恶化或改善没有很好的相关性。填塞总是先于舒张功能障碍,组织多普勒成像(TDI)可以帮助早期发现它,比传统的迹象更早。为此,我们对36例心包积液患者进行了超声心动图检查,包括积液的大小、是否存在常规的心包填塞征象、tdi引起的左心室和右心室E/E比,以及心包填塞的临床征象,以检验超声心动图参数对其诊断的准确性。右心房和心室塌陷对心包填塞的诊断准确率最低,而积液尺寸> 14 mm对心包填塞的诊断准确率最高。通过E/E′比值判断左室和左室舒张功能不全对预测压塞的敏感性为100%,而在相同情况下,左室E/E′比值的特异性最高(100%)。左室E/E比值较高的诊断准确性也可能与存在慢性肾病患者,且左室功能已经受损有关。TDI技术现在可用于大多数便携式超声心动图机,并可作为即时超声心动图的一部分,用于心脏填塞的早期检测和心包穿刺的决策。更大规模的研究可以帮助巩固我们从小规模横断面研究中得到的印象。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Tissue Doppler vs. conventional parameters for diagnosis of tamponading pericardial effusion: a cross-sectional study in tertiary referral center
Conventional signs of tamponade include right ventricular and atrial collapse and respiratory variation in mitral inflow velocities. Despite being reliable, they are qualitative in nature and are not well correlated with clinical signs of deterioration or improvement. Tamponade is invariably preceded and associated with diastolic dysfunction, and tissue Doppler imaging (TDI) can help in early detection of it, earlier than conventional signs. For this purpose, 36 patients presenting with pericardial effusion have been subjected to echocardiography, including effusion dimensions, presence or absence of routine signs of tamponade and TDI-derived LV and RV E/E′ ratios, as well as clinical signs of tamponade to test the diagnostic accuracy of echocardiographic parameters against them. Right atrial and ventricular collapse were the least accurate in the detection of tamponade, while effusion dimension > 14 mm was the most accurate among conventional parameters to point toward tamponade. RV and LV diastolic dysfunction as evidenced by E/E′ ratio showed 100% sensitivity in predicting tamponade, while LV E/E′ ratio showed the highest specificity (100%) in the same context. The higher diagnostic accuracy of LV E/E′ ratio might be also related to the presence of chronic kidney disease patients, with an already jeopardized LV function. TDI technology is now available in most of the portable echocardiography machines and can serve as part of point-of-care echocardiography in the early detection of cardiac tamponade and in decision making for pericardiocentesis. Larger studies can help in consolidating the impression driven from our small-scale cross-sectional study.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
32
审稿时长
9 weeks
期刊介绍: The Gazette is the official journal of the Egyptian Pediatric Association. The main purpose of the Gazette is to provide a place for the publication of high-quality papers documenting recent advances and new developments in both pediatrics and pediatric surgery in clinical and experimental settings. An equally important purpose of the Gazette is to publish local and regional issues related to children and child care. The Gazette welcomes original papers, review articles, case reports and short communications as well as short technical reports. Papers submitted to the Gazette are peer-reviewed by a large review board. The Gazette also offers CME quizzes, credits for which can be claimed from either the EPA website or the EPA headquarters. Fields of interest: all aspects of pediatrics, pediatric surgery, child health and child care. The Gazette complies with the Uniform Requirements for Manuscripts submitted to biomedical journals as recommended by the International Committee of Medical Journal Editors (ICMJE).
期刊最新文献
Multisystem inflammatory syndrome in children treated with intravenous immunoglobulin monotherapy: a single-center retrospective study Posterior reversible encephalopathy syndrome in a known case of beta-thalassemia major after blood transfusion: a case presentation Egyptian paediatric kidney transplantation pre-transplant guidance highlights on donor and recipient assessment (R. N. 364) Prevalence and CCR3-T51C genotype–phenotype correlation of bronchial asthma among basic education school children: an observational study Fever of unknown origin in pediatrics: causes and clinical characteristics in a single centre experience
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1