{"title":"电化学生成的铝--用于修复含有 2,4-二氯苯酚的废水","authors":"H. Simol, R. A. Jahan","doi":"10.9734/ajocs/2023/v13i6274","DOIUrl":null,"url":null,"abstract":"An effective treatment process for 2,4-dichlorophenol (2,4-DCP) in wastewater is highly essential, since it may cause great threat to our environment. In such context, a low-cost potential and environment-friendly technique has been demonstrated for the removal of a toxic compound 2,4-DCP from aqueous media. The electrochemically generated aluminum sorbent was used to remove 2,4-DCP from waste water by in-situ electrocoagulation and by adsorption. The experimental findings were analyzed based on the percent removal of 2,4-DCP with time. DCP-containing wastewater was electrocoagulated in a two-electrode monopolar electrocoagulation cell with aluminum as the sacrificial anode and 0.05 M NaCl as the internal electrolyte, with the electrolyte concentration kept constant throughout the experiment. Starting concentration and pH were found to have a significant impact on the electrocoagulation process for removing 2,4-DCP from wastewater.","PeriodicalId":8505,"journal":{"name":"Asian Journal of Chemical Sciences","volume":"15 5","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Electrochemically Generated Aluminum-Species for Remediation of Waste Water Containing 2, 4-Dichlorophenol\",\"authors\":\"H. Simol, R. A. Jahan\",\"doi\":\"10.9734/ajocs/2023/v13i6274\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An effective treatment process for 2,4-dichlorophenol (2,4-DCP) in wastewater is highly essential, since it may cause great threat to our environment. In such context, a low-cost potential and environment-friendly technique has been demonstrated for the removal of a toxic compound 2,4-DCP from aqueous media. The electrochemically generated aluminum sorbent was used to remove 2,4-DCP from waste water by in-situ electrocoagulation and by adsorption. The experimental findings were analyzed based on the percent removal of 2,4-DCP with time. DCP-containing wastewater was electrocoagulated in a two-electrode monopolar electrocoagulation cell with aluminum as the sacrificial anode and 0.05 M NaCl as the internal electrolyte, with the electrolyte concentration kept constant throughout the experiment. Starting concentration and pH were found to have a significant impact on the electrocoagulation process for removing 2,4-DCP from wastewater.\",\"PeriodicalId\":8505,\"journal\":{\"name\":\"Asian Journal of Chemical Sciences\",\"volume\":\"15 5\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-12-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asian Journal of Chemical Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.9734/ajocs/2023/v13i6274\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Chemical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9734/ajocs/2023/v13i6274","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
废水中2,4-二氯酚(2,4- dcp)的有效处理工艺是非常必要的,因为它可能对我们的环境造成很大的威胁。在这种情况下,一种低成本、环保的技术已经被证明可以从水介质中去除有毒化合物2,4-二氯苯酚。采用原位电絮凝和吸附两种方法对废水中的2,4-二氯苯酚进行了电化学合成铝吸附剂的去除。根据2,4- dcp去除率随时间的变化对实验结果进行了分析。以铝为牺牲阳极,0.05 M NaCl为内电解质,在双电极单极电凝池中对含dcp废水进行电凝处理,整个实验过程中保持电解质浓度不变。研究发现,初始浓度和pH值对电凝法去除废水中2,4-二氯苯酚有显著影响。
Electrochemically Generated Aluminum-Species for Remediation of Waste Water Containing 2, 4-Dichlorophenol
An effective treatment process for 2,4-dichlorophenol (2,4-DCP) in wastewater is highly essential, since it may cause great threat to our environment. In such context, a low-cost potential and environment-friendly technique has been demonstrated for the removal of a toxic compound 2,4-DCP from aqueous media. The electrochemically generated aluminum sorbent was used to remove 2,4-DCP from waste water by in-situ electrocoagulation and by adsorption. The experimental findings were analyzed based on the percent removal of 2,4-DCP with time. DCP-containing wastewater was electrocoagulated in a two-electrode monopolar electrocoagulation cell with aluminum as the sacrificial anode and 0.05 M NaCl as the internal electrolyte, with the electrolyte concentration kept constant throughout the experiment. Starting concentration and pH were found to have a significant impact on the electrocoagulation process for removing 2,4-DCP from wastewater.