Alejandro R Foley, Gizette Sperinde, Saloumeh K Fischer
{"title":"扩大检测范围,以适应血液和脑脊液中单克隆抗体的治疗定量。","authors":"Alejandro R Foley, Gizette Sperinde, Saloumeh K Fischer","doi":"10.4155/bio-2023-0179","DOIUrl":null,"url":null,"abstract":"<p><p>Antibody therapeutic levels in neurodegenerative diseases are often measured in both serum and cerebrospinal fluid (CSF). Due to 0.1% drug partition from serum to CSF and the higher sensitivity needs, usually two different assays are required. The different Gyrolab Bioaffy compact discs can extend the dynamic range of assays. Here, an assay was developed and adapted on two different Gyrolab Bioaffy compact discs (200 and 4000 nl) to achieve the required sensitivity and assay dynamic range needed for the measurement of drug in both serum and CSF. This was accomplished by using the same critical reagents with minimal assay development to transition from a serum to a CSF assay.</p>","PeriodicalId":8797,"journal":{"name":"Bioanalysis","volume":" ","pages":"129-140"},"PeriodicalIF":1.9000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Expanding assay range to accommodate a monoclonal antibody therapeutic quantification in blood and cerebrospinal fluid.\",\"authors\":\"Alejandro R Foley, Gizette Sperinde, Saloumeh K Fischer\",\"doi\":\"10.4155/bio-2023-0179\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Antibody therapeutic levels in neurodegenerative diseases are often measured in both serum and cerebrospinal fluid (CSF). Due to 0.1% drug partition from serum to CSF and the higher sensitivity needs, usually two different assays are required. The different Gyrolab Bioaffy compact discs can extend the dynamic range of assays. Here, an assay was developed and adapted on two different Gyrolab Bioaffy compact discs (200 and 4000 nl) to achieve the required sensitivity and assay dynamic range needed for the measurement of drug in both serum and CSF. This was accomplished by using the same critical reagents with minimal assay development to transition from a serum to a CSF assay.</p>\",\"PeriodicalId\":8797,\"journal\":{\"name\":\"Bioanalysis\",\"volume\":\" \",\"pages\":\"129-140\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bioanalysis\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4155/bio-2023-0179\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/12/13 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioanalysis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4155/bio-2023-0179","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/13 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
Expanding assay range to accommodate a monoclonal antibody therapeutic quantification in blood and cerebrospinal fluid.
Antibody therapeutic levels in neurodegenerative diseases are often measured in both serum and cerebrospinal fluid (CSF). Due to 0.1% drug partition from serum to CSF and the higher sensitivity needs, usually two different assays are required. The different Gyrolab Bioaffy compact discs can extend the dynamic range of assays. Here, an assay was developed and adapted on two different Gyrolab Bioaffy compact discs (200 and 4000 nl) to achieve the required sensitivity and assay dynamic range needed for the measurement of drug in both serum and CSF. This was accomplished by using the same critical reagents with minimal assay development to transition from a serum to a CSF assay.
BioanalysisBIOCHEMICAL RESEARCH METHODS-CHEMISTRY, ANALYTICAL
CiteScore
3.30
自引率
16.70%
发文量
88
审稿时长
2 months
期刊介绍:
Reliable data obtained from selective, sensitive and reproducible analysis of xenobiotics and biotics in biological samples is a fundamental and crucial part of every successful drug development program. The same principles can also apply to many other areas of research such as forensic science, toxicology and sports doping testing.
The bioanalytical field incorporates sophisticated techniques linking sample preparation and advanced separations with MS and NMR detection systems, automation and robotics. Standards set by regulatory bodies regarding method development and validation increasingly define the boundaries between speed and quality.
Bioanalysis is a progressive discipline for which the future holds many exciting opportunities to further reduce sample volumes, analysis cost and environmental impact, as well as to improve sensitivity, specificity, accuracy, efficiency, assay throughput, data quality, data handling and processing.
The journal Bioanalysis focuses on the techniques and methods used for the detection or quantitative study of analytes in human or animal biological samples. Bioanalysis encourages the submission of articles describing forward-looking applications, including biosensors, microfluidics, miniaturized analytical devices, and new hyphenated and multi-dimensional techniques.
Bioanalysis delivers essential information in concise, at-a-glance article formats. Key advances in the field are reported and analyzed by international experts, providing an authoritative but accessible forum for the modern bioanalyst.