{"title":"[脉冲直流电喷雾质谱法快速检测头发中的四种苯丙胺类药物]。","authors":"Kun Mi, Wentian Zhang, Luhong Wen, Jin Wang","doi":"10.3724/SP.J.1123.2023.04002","DOIUrl":null,"url":null,"abstract":"<p><p>Amphetamine-type drugs are synthetic compounds with an amphetamine parent structure. These compounds cause addiction, central nervous system excitation, and hallucinations. The number of drug users worldwide has gradually increased because amphetamine-type drugs can be synthesized in a simple and artificial manner. The current methods for anti-drug screening and toxicant identification are limited by the large quantity and variety of the drug analytes and long detection times. Thus, the development of broad-spectrum, rapid, and high-throughput detection methods is an urgent necessity. In addition, conventional amphetamine-type drug test samples, such as blood and urine, are only suitable for short-term drug identification. Hair has the advantages of easy preservation, stability, and a long detection window, which can compensate for the deficiencies of body-fluid-based test materials. Hair samples can reflect long-term drug use, which is beneficial for tracing drug sources, and has become an important means of providing evidence in court. Because most laboratory instruments are unable to perform the rapid on-site detection of amphetamine-type drugs in hair, establishing a high-throughput, qualitative and quantitative rapid on-site detection method is necessary. In this study, pulsed direct current electrospray ionization (Pulsed-DC-ESI) coupled with mass spectrometry was used for the rapid detection of four amphetamine-type drugs (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, and 3,4-methylenedioxymethamphetamine) in hair. Methanol was used as the extraction solvent, and the grinding method was used for extraction. The pretreatment process included cutting, grinding, and centrifugation. The pretreatment time for each sample was about 10 min. Multiple samples could be processed in batches, greatly improving the efficiency of analysis. Pulsed-DC-ESI is an ambient ionization technology that can be conducted via direct injection without chromatographic separation. The tip of the spray capillary tube was immersed 1 cm below the surface of the sample solution to allow absorption via the capillary effect. When the spray capillary tube contained 1 μL of the sample solution, detection was performed. Pulsed-DC-ESI generates an electrospray at the same frequency as the mass spectrum, thereby avoiding the problem of sample wastage, which often occurs in traditional ESI. The portable mass spectrometer used for analysis is a linear ion trap mass spectrometer. The parameters of Pulsed-DC-ESI, such as the inner diameter of spray capillary tip, spray voltage, and distance between electrode and solution, were optimized based on the mass spectral responses of the amphetamine-type drugs. The optimized ion source conditions included a inner diameter of spray capillary tip of 25 μm, spray voltage of 2 kV, and the distance between electrode and solution of 20 mm. The optimal sample solvent was methanol. The optimized method can achieve simultaneous detection of the four amphetamine-type drugs within 20 s. The linear ranges of amphetamine, methamphetamine, and the two other drugs were 1-25, 1-100, and 1-50 ng/mg, respectively. The limits of detection and quantification of the four drugs in hair were 0.1-0.2 and 1 ng/mg, respectively. All linear correlation coefficients were greater than 0.99, and the average spiked recoveries were 86.6%-114.7%. The intra-day precisions were 4.14%-7.34%, and the inter-day precisions were 3.71%-8.43%. The proposed method was used to screen 2000 samples provided by various testing institutions. A total of five samples were positive for methamphetamine, which is consistent with the results of conventional forensic identification methods. Thus, the developed method can be used for the rapid detection of amphetamine-type drugs.</p>","PeriodicalId":9864,"journal":{"name":"色谱","volume":"41 12","pages":"1141-1148"},"PeriodicalIF":1.2000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10719801/pdf/","citationCount":"0","resultStr":"{\"title\":\"[Rapid detection of four amphetamine-type drugs in hair by pulsed direct current electrospray mass spectrometry].\",\"authors\":\"Kun Mi, Wentian Zhang, Luhong Wen, Jin Wang\",\"doi\":\"10.3724/SP.J.1123.2023.04002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Amphetamine-type drugs are synthetic compounds with an amphetamine parent structure. These compounds cause addiction, central nervous system excitation, and hallucinations. The number of drug users worldwide has gradually increased because amphetamine-type drugs can be synthesized in a simple and artificial manner. The current methods for anti-drug screening and toxicant identification are limited by the large quantity and variety of the drug analytes and long detection times. Thus, the development of broad-spectrum, rapid, and high-throughput detection methods is an urgent necessity. In addition, conventional amphetamine-type drug test samples, such as blood and urine, are only suitable for short-term drug identification. Hair has the advantages of easy preservation, stability, and a long detection window, which can compensate for the deficiencies of body-fluid-based test materials. Hair samples can reflect long-term drug use, which is beneficial for tracing drug sources, and has become an important means of providing evidence in court. Because most laboratory instruments are unable to perform the rapid on-site detection of amphetamine-type drugs in hair, establishing a high-throughput, qualitative and quantitative rapid on-site detection method is necessary. In this study, pulsed direct current electrospray ionization (Pulsed-DC-ESI) coupled with mass spectrometry was used for the rapid detection of four amphetamine-type drugs (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, and 3,4-methylenedioxymethamphetamine) in hair. Methanol was used as the extraction solvent, and the grinding method was used for extraction. The pretreatment process included cutting, grinding, and centrifugation. The pretreatment time for each sample was about 10 min. Multiple samples could be processed in batches, greatly improving the efficiency of analysis. Pulsed-DC-ESI is an ambient ionization technology that can be conducted via direct injection without chromatographic separation. The tip of the spray capillary tube was immersed 1 cm below the surface of the sample solution to allow absorption via the capillary effect. When the spray capillary tube contained 1 μL of the sample solution, detection was performed. Pulsed-DC-ESI generates an electrospray at the same frequency as the mass spectrum, thereby avoiding the problem of sample wastage, which often occurs in traditional ESI. The portable mass spectrometer used for analysis is a linear ion trap mass spectrometer. The parameters of Pulsed-DC-ESI, such as the inner diameter of spray capillary tip, spray voltage, and distance between electrode and solution, were optimized based on the mass spectral responses of the amphetamine-type drugs. The optimized ion source conditions included a inner diameter of spray capillary tip of 25 μm, spray voltage of 2 kV, and the distance between electrode and solution of 20 mm. The optimal sample solvent was methanol. The optimized method can achieve simultaneous detection of the four amphetamine-type drugs within 20 s. The linear ranges of amphetamine, methamphetamine, and the two other drugs were 1-25, 1-100, and 1-50 ng/mg, respectively. The limits of detection and quantification of the four drugs in hair were 0.1-0.2 and 1 ng/mg, respectively. All linear correlation coefficients were greater than 0.99, and the average spiked recoveries were 86.6%-114.7%. The intra-day precisions were 4.14%-7.34%, and the inter-day precisions were 3.71%-8.43%. The proposed method was used to screen 2000 samples provided by various testing institutions. A total of five samples were positive for methamphetamine, which is consistent with the results of conventional forensic identification methods. Thus, the developed method can be used for the rapid detection of amphetamine-type drugs.</p>\",\"PeriodicalId\":9864,\"journal\":{\"name\":\"色谱\",\"volume\":\"41 12\",\"pages\":\"1141-1148\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10719801/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"色谱\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.3724/SP.J.1123.2023.04002\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"色谱","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.3724/SP.J.1123.2023.04002","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
[Rapid detection of four amphetamine-type drugs in hair by pulsed direct current electrospray mass spectrometry].
Amphetamine-type drugs are synthetic compounds with an amphetamine parent structure. These compounds cause addiction, central nervous system excitation, and hallucinations. The number of drug users worldwide has gradually increased because amphetamine-type drugs can be synthesized in a simple and artificial manner. The current methods for anti-drug screening and toxicant identification are limited by the large quantity and variety of the drug analytes and long detection times. Thus, the development of broad-spectrum, rapid, and high-throughput detection methods is an urgent necessity. In addition, conventional amphetamine-type drug test samples, such as blood and urine, are only suitable for short-term drug identification. Hair has the advantages of easy preservation, stability, and a long detection window, which can compensate for the deficiencies of body-fluid-based test materials. Hair samples can reflect long-term drug use, which is beneficial for tracing drug sources, and has become an important means of providing evidence in court. Because most laboratory instruments are unable to perform the rapid on-site detection of amphetamine-type drugs in hair, establishing a high-throughput, qualitative and quantitative rapid on-site detection method is necessary. In this study, pulsed direct current electrospray ionization (Pulsed-DC-ESI) coupled with mass spectrometry was used for the rapid detection of four amphetamine-type drugs (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, and 3,4-methylenedioxymethamphetamine) in hair. Methanol was used as the extraction solvent, and the grinding method was used for extraction. The pretreatment process included cutting, grinding, and centrifugation. The pretreatment time for each sample was about 10 min. Multiple samples could be processed in batches, greatly improving the efficiency of analysis. Pulsed-DC-ESI is an ambient ionization technology that can be conducted via direct injection without chromatographic separation. The tip of the spray capillary tube was immersed 1 cm below the surface of the sample solution to allow absorption via the capillary effect. When the spray capillary tube contained 1 μL of the sample solution, detection was performed. Pulsed-DC-ESI generates an electrospray at the same frequency as the mass spectrum, thereby avoiding the problem of sample wastage, which often occurs in traditional ESI. The portable mass spectrometer used for analysis is a linear ion trap mass spectrometer. The parameters of Pulsed-DC-ESI, such as the inner diameter of spray capillary tip, spray voltage, and distance between electrode and solution, were optimized based on the mass spectral responses of the amphetamine-type drugs. The optimized ion source conditions included a inner diameter of spray capillary tip of 25 μm, spray voltage of 2 kV, and the distance between electrode and solution of 20 mm. The optimal sample solvent was methanol. The optimized method can achieve simultaneous detection of the four amphetamine-type drugs within 20 s. The linear ranges of amphetamine, methamphetamine, and the two other drugs were 1-25, 1-100, and 1-50 ng/mg, respectively. The limits of detection and quantification of the four drugs in hair were 0.1-0.2 and 1 ng/mg, respectively. All linear correlation coefficients were greater than 0.99, and the average spiked recoveries were 86.6%-114.7%. The intra-day precisions were 4.14%-7.34%, and the inter-day precisions were 3.71%-8.43%. The proposed method was used to screen 2000 samples provided by various testing institutions. A total of five samples were positive for methamphetamine, which is consistent with the results of conventional forensic identification methods. Thus, the developed method can be used for the rapid detection of amphetamine-type drugs.
期刊介绍:
"Chinese Journal of Chromatography" mainly reports the basic research results of chromatography, important application results of chromatography and its interdisciplinary subjects and their progress, including the application of new methods, new technologies, and new instruments in various fields, the research and development of chromatography instruments and components, instrument analysis teaching research, etc. It is suitable for researchers engaged in chromatography basic and application technology research in scientific research institutes, master and doctoral students in chromatography and related disciplines, grassroots researchers in the field of analysis and testing, and relevant personnel in chromatography instrument development and operation units.
The journal has columns such as special planning, focus, perspective, research express, research paper, monograph and review, micro review, technology and application, and teaching research.