基于设计的薄层色谱分析质量方法的开发与验证,用于片剂抗肿瘤药物阿西替尼的检测和含量均匀性测试

IF 1.3 Q4 CHEMISTRY, ANALYTICAL SEPARATION SCIENCE PLUS Pub Date : 2023-12-13 DOI:10.1002/sscp.202300176
Shaileshkumar K. Koradia, Madhavi Patel, A. Sen, D. Sen, Prasanna Pradhan
{"title":"基于设计的薄层色谱分析质量方法的开发与验证,用于片剂抗肿瘤药物阿西替尼的检测和含量均匀性测试","authors":"Shaileshkumar K. Koradia, Madhavi Patel, A. Sen, D. Sen, Prasanna Pradhan","doi":"10.1002/sscp.202300176","DOIUrl":null,"url":null,"abstract":"The current study aims to develop and validate an analytical quality by design approach‐based high‐performance thin‐layer chromatographic (HPTLC) method for the analysis of Axitinib tablet samples. The chromatographic conditions in the TLC method were optimized using a three‐level full factorial design. The mobile phase composition and chamber saturation time served as the independent variables for optimization. The mobile phase used for TLC separation on pre‐coated aluminum plates with silica gel 60 F254 consisted of a mixture of ethyl acetate and isopropyl alcohol in a ratio of 9:1 (v/v). Axitinib was quantified at 330 nm using the densitometric method. Axitinib peak from tablet formulation was verified against the reference standard by comparing its single band at Rf 0.44 ± 0.02. Linearity was found to exist between 100 and 600 ng/band, with a correlation coefficient (r2) of 0.9978. The percentage recovery was obtained as 98.21%–99.05%. The system was validated by determining the parameters according to the guidelines of the International Council for Harmonization of Technical Conditions for Medical Products for Human Use. The proposed TLC method can be effectively applied to routine quality control of a pharmaceutical product.","PeriodicalId":21639,"journal":{"name":"SEPARATION SCIENCE PLUS","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2023-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analytical quality by design‐based thin‐layer chromatography method development and validation for assay and content uniformity testing of the anti‐neoplastic drug Axitinib in tablet formulation\",\"authors\":\"Shaileshkumar K. Koradia, Madhavi Patel, A. Sen, D. Sen, Prasanna Pradhan\",\"doi\":\"10.1002/sscp.202300176\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The current study aims to develop and validate an analytical quality by design approach‐based high‐performance thin‐layer chromatographic (HPTLC) method for the analysis of Axitinib tablet samples. The chromatographic conditions in the TLC method were optimized using a three‐level full factorial design. The mobile phase composition and chamber saturation time served as the independent variables for optimization. The mobile phase used for TLC separation on pre‐coated aluminum plates with silica gel 60 F254 consisted of a mixture of ethyl acetate and isopropyl alcohol in a ratio of 9:1 (v/v). Axitinib was quantified at 330 nm using the densitometric method. Axitinib peak from tablet formulation was verified against the reference standard by comparing its single band at Rf 0.44 ± 0.02. Linearity was found to exist between 100 and 600 ng/band, with a correlation coefficient (r2) of 0.9978. The percentage recovery was obtained as 98.21%–99.05%. The system was validated by determining the parameters according to the guidelines of the International Council for Harmonization of Technical Conditions for Medical Products for Human Use. The proposed TLC method can be effectively applied to routine quality control of a pharmaceutical product.\",\"PeriodicalId\":21639,\"journal\":{\"name\":\"SEPARATION SCIENCE PLUS\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2023-12-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SEPARATION SCIENCE PLUS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/sscp.202300176\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SEPARATION SCIENCE PLUS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/sscp.202300176","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在开发并验证一种基于设计方法的高效薄层色谱(HPTLC)分析阿西替尼片剂样品的分析质量。采用三级全因子设计对 TLC 方法中的色谱条件进行了优化。流动相组成和室饱和时间是优化的自变量。在预涂硅胶 60 F254 的铝板上进行 TLC 分离时使用的流动相由乙酸乙酯和异丙醇以 9:1 (v/v) 的比例混合而成。阿昔替尼在 330 纳米波长处采用密度计法进行定量。通过比较 Rf 为 0.44 ± 0.02 的单一条带,将片剂中的阿西替尼峰与标准物质进行比对。在 100 至 600 纳克/带之间存在线性关系,相关系数 (r2) 为 0.9978。回收率为 98.21%-99.05%。根据国际人用医药产品技术条件协调理事会的指导原则确定了系统的参数,并对其进行了验证。所提出的 TLC 方法可有效地应用于药品的常规质量控制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analytical quality by design‐based thin‐layer chromatography method development and validation for assay and content uniformity testing of the anti‐neoplastic drug Axitinib in tablet formulation
The current study aims to develop and validate an analytical quality by design approach‐based high‐performance thin‐layer chromatographic (HPTLC) method for the analysis of Axitinib tablet samples. The chromatographic conditions in the TLC method were optimized using a three‐level full factorial design. The mobile phase composition and chamber saturation time served as the independent variables for optimization. The mobile phase used for TLC separation on pre‐coated aluminum plates with silica gel 60 F254 consisted of a mixture of ethyl acetate and isopropyl alcohol in a ratio of 9:1 (v/v). Axitinib was quantified at 330 nm using the densitometric method. Axitinib peak from tablet formulation was verified against the reference standard by comparing its single band at Rf 0.44 ± 0.02. Linearity was found to exist between 100 and 600 ng/band, with a correlation coefficient (r2) of 0.9978. The percentage recovery was obtained as 98.21%–99.05%. The system was validated by determining the parameters according to the guidelines of the International Council for Harmonization of Technical Conditions for Medical Products for Human Use. The proposed TLC method can be effectively applied to routine quality control of a pharmaceutical product.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
SEPARATION SCIENCE PLUS
SEPARATION SCIENCE PLUS CHEMISTRY, ANALYTICAL-
CiteScore
1.90
自引率
9.10%
发文量
111
期刊最新文献
Removal of Residual DNA and Host Cell Proteins for the Purification of Recombinant Staphylokinase Expressed in Escherichia coli Green Analytical Approach for HPLC Method Development for Quantification of Sorafenib and Its Pharmacopeia Impurities: LC–MS/MS Characterization and Toxicity Prediction of Stress Degradation Products A Cartridge Structure Facilitates Clinical Mass Spectrometry Pretreatment and Can be Integrated Into a High‐Throughput Instrument Comparison of Polysaccharide Profiles of Different Seaweeds Based on Ion Chromatography and Ultrahigh‐Performance Liquid Chromatography Quantification of Recycled Polypropylene Stabilizers for Quality Control by Liquid Chromatography–Tandem Mass Spectrometry Using Simple, Fast and Efficient Ultrasonic Extraction
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1