房颤肺静脉隔离的超高功率短时消融与传统消融:系统性回顾和 Meta 分析。

IF 2.6 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS Arrhythmia & Electrophysiology Review Pub Date : 2023-12-07 eCollection Date: 2023-01-01 DOI:10.15420/aer.2023.19
Raymond Pranata, Giky Karwiky, Mohammad Iqbal
{"title":"房颤肺静脉隔离的超高功率短时消融与传统消融:系统性回顾和 Meta 分析。","authors":"Raymond Pranata, Giky Karwiky, Mohammad Iqbal","doi":"10.15420/aer.2023.19","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to compare the effectiveness and safety of very-high-power short-duration (VHPSD) ablation (70-90 W/4-7 s) with conventional ablation (30-40 W/>20 s, 50 W/7-11 s) for pulmonary vein isolation (PVI) in patients with AF. A total of 13 studies were included in this analysis (1,527 patients). AF recurrence occurred in 14% (95% CI [11-18%]) of the VHPSD group. VHPSD was associated with lower AF recurrence (OR 0.65; 95% CI [0.48-0.89]; p=0.006) compared with the conventional ablation group. Subgroup analysis showed that additional ablation beyond PVI had a similar rate of AF recurrence (16% versus 10%) compared with PVI alone. Procedure and ablation durations were significantly shorter in the VHPSD group with a mean differences of -14.4 minutes (p=0.017) and -14.1 minutes (p<0.001), respectively. Complications occurred in 6% (95% CI [3-9%]) of the VHPSD group, and the rate was similar between the two groups (OR 1.03; 95% CI [0.60-1.80]; p=0.498). VHPSD ablation resulted in less AF recurrence and a shorter procedure time. Additional ablation beyond PVI alone in VHPSD may not provide additional benefits.</p>","PeriodicalId":8412,"journal":{"name":"Arrhythmia & Electrophysiology Review","volume":"12 ","pages":"e30"},"PeriodicalIF":2.6000,"publicationDate":"2023-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10762667/pdf/","citationCount":"0","resultStr":"{\"title\":\"Very-high-power Short-duration Ablation versus Conventional Ablation for Pulmonary Vein Isolation in Atrial Fibrillation: Systematic Review and Meta-analysis.\",\"authors\":\"Raymond Pranata, Giky Karwiky, Mohammad Iqbal\",\"doi\":\"10.15420/aer.2023.19\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The aim of this study was to compare the effectiveness and safety of very-high-power short-duration (VHPSD) ablation (70-90 W/4-7 s) with conventional ablation (30-40 W/>20 s, 50 W/7-11 s) for pulmonary vein isolation (PVI) in patients with AF. A total of 13 studies were included in this analysis (1,527 patients). AF recurrence occurred in 14% (95% CI [11-18%]) of the VHPSD group. VHPSD was associated with lower AF recurrence (OR 0.65; 95% CI [0.48-0.89]; p=0.006) compared with the conventional ablation group. Subgroup analysis showed that additional ablation beyond PVI had a similar rate of AF recurrence (16% versus 10%) compared with PVI alone. Procedure and ablation durations were significantly shorter in the VHPSD group with a mean differences of -14.4 minutes (p=0.017) and -14.1 minutes (p<0.001), respectively. Complications occurred in 6% (95% CI [3-9%]) of the VHPSD group, and the rate was similar between the two groups (OR 1.03; 95% CI [0.60-1.80]; p=0.498). VHPSD ablation resulted in less AF recurrence and a shorter procedure time. Additional ablation beyond PVI alone in VHPSD may not provide additional benefits.</p>\",\"PeriodicalId\":8412,\"journal\":{\"name\":\"Arrhythmia & Electrophysiology Review\",\"volume\":\"12 \",\"pages\":\"e30\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2023-12-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10762667/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Arrhythmia & Electrophysiology Review\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15420/aer.2023.19\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arrhythmia & Electrophysiology Review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15420/aer.2023.19","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在比较超高功率短时消融术(70-90 瓦/4-7 秒)与传统消融术(30-40 瓦/>20 秒,50 瓦/7-11 秒)对房颤患者进行肺静脉隔离(PVI)的有效性和安全性。本分析共纳入 13 项研究(1527 名患者)。在 VHPSD 组中,房颤复发率为 14%(95% CI [11-18%])。与传统消融组相比,VHPSD 与较低的房颤复发率相关(OR 0.65;95% CI [0.48-0.89];P=0.006)。亚组分析显示,与单纯 PVI 相比,PVI 以外的额外消融的房颤复发率相似(16% 对 10%)。VHPSD 组的手术和消融持续时间明显缩短,平均差异为 -14.4 分钟(p=0.017)和 -14.1 分钟(p=0.006)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Very-high-power Short-duration Ablation versus Conventional Ablation for Pulmonary Vein Isolation in Atrial Fibrillation: Systematic Review and Meta-analysis.

The aim of this study was to compare the effectiveness and safety of very-high-power short-duration (VHPSD) ablation (70-90 W/4-7 s) with conventional ablation (30-40 W/>20 s, 50 W/7-11 s) for pulmonary vein isolation (PVI) in patients with AF. A total of 13 studies were included in this analysis (1,527 patients). AF recurrence occurred in 14% (95% CI [11-18%]) of the VHPSD group. VHPSD was associated with lower AF recurrence (OR 0.65; 95% CI [0.48-0.89]; p=0.006) compared with the conventional ablation group. Subgroup analysis showed that additional ablation beyond PVI had a similar rate of AF recurrence (16% versus 10%) compared with PVI alone. Procedure and ablation durations were significantly shorter in the VHPSD group with a mean differences of -14.4 minutes (p=0.017) and -14.1 minutes (p<0.001), respectively. Complications occurred in 6% (95% CI [3-9%]) of the VHPSD group, and the rate was similar between the two groups (OR 1.03; 95% CI [0.60-1.80]; p=0.498). VHPSD ablation resulted in less AF recurrence and a shorter procedure time. Additional ablation beyond PVI alone in VHPSD may not provide additional benefits.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Arrhythmia & Electrophysiology Review
Arrhythmia & Electrophysiology Review CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
5.10
自引率
6.70%
发文量
22
审稿时长
7 weeks
期刊最新文献
Catheter Ablation for Vasovagal Syncope: The Therapeutic Potential of Gateway Plexi. Functional Substrate Mapping: A New Frontier in the Treatment of Ventricular Tachycardia in Structural Heart Disease. Revisiting the Atrioventricular Conduction Axis for the 21st Century. Conduction System Pacing in Children and Congenital Heart Disease. Association Between Atrial Fibrillation and Long-term Mortality in Acute MI Patients.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1