从干血斑中提取哌喹的高通量 LC-MS/MS 检测方法:改善资源有限环境中的疟疾治疗

IF 3.1 4区 医学 Q2 MEDICAL LABORATORY TECHNOLOGY Journal of Mass Spectrometry and Advances in the Clinical Lab Pub Date : 2024-01-01 DOI:10.1016/j.jmsacl.2023.12.004
Daniel Blessborn , Natpapat Kaewkhao , Joel Tarning
{"title":"从干血斑中提取哌喹的高通量 LC-MS/MS 检测方法:改善资源有限环境中的疟疾治疗","authors":"Daniel Blessborn ,&nbsp;Natpapat Kaewkhao ,&nbsp;Joel Tarning","doi":"10.1016/j.jmsacl.2023.12.004","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Malaria is a parasitic disease that affects many of the poorest economies, resulting in approximately 241 million clinical episodes and 627,000 deaths annually. Piperaquine, when administered with dihydroartemisinin, is an effective drug against the disease. Drug concentration measurements taken on day 7 after treatment initiation have been shown to be a good predictor of therapeutic success with piperaquine. A simple capillary blood collection technique, where blood is dried onto filter paper, is especially suitable for drug studies in remote areas or resource-limited settings or when taking samples from children, toddlers, and infants.</p></div><div><h3>Methods</h3><p>Three 3.2 mm discs were punched out from a dried blood spot (DBS) and then extracted in a 96-well plate using solid phase extraction on a fully automated liquid handling system. The analysis was performed using LC-MS/MS with a calibration range of 3 – 1000 ng/mL.</p></div><div><h3>Results</h3><p>The recovery rate was approximately 54–72 %, and the relative standard deviation was below 9 % for low, middle and high quality control levels. The LC-MS/MS quantification limit of 3 ng/mL is sensitive enough to detect piperaquine for up to 4–8 weeks after drug administration, which is crucial when evaluating recrudescence and drug resistance development. While different hematocrit levels can affect DBS drug measurements, the effect was minimal for piperaquine.</p></div><div><h3>Conclusion</h3><p>A sensitive LC-MS/MS method, in combination with fully automated extraction in a 96-well plate format, was developed and validated for the quantification of piperaquine in DBS. The assay was implemented in a bioanalytical laboratory for processing large-scale clinical trial samples.</p></div>","PeriodicalId":52406,"journal":{"name":"Journal of Mass Spectrometry and Advances in the Clinical Lab","volume":"31 ","pages":"Pages 19-26"},"PeriodicalIF":3.1000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2667145X23000421/pdfft?md5=cdb560cd35ba8072bfcd7a8f31c71e9d&pid=1-s2.0-S2667145X23000421-main.pdf","citationCount":"0","resultStr":"{\"title\":\"A high-throughput LC-MS/MS assay for piperaquine from dried blood spots: Improving malaria treatment in resource-limited settings\",\"authors\":\"Daniel Blessborn ,&nbsp;Natpapat Kaewkhao ,&nbsp;Joel Tarning\",\"doi\":\"10.1016/j.jmsacl.2023.12.004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Malaria is a parasitic disease that affects many of the poorest economies, resulting in approximately 241 million clinical episodes and 627,000 deaths annually. Piperaquine, when administered with dihydroartemisinin, is an effective drug against the disease. Drug concentration measurements taken on day 7 after treatment initiation have been shown to be a good predictor of therapeutic success with piperaquine. A simple capillary blood collection technique, where blood is dried onto filter paper, is especially suitable for drug studies in remote areas or resource-limited settings or when taking samples from children, toddlers, and infants.</p></div><div><h3>Methods</h3><p>Three 3.2 mm discs were punched out from a dried blood spot (DBS) and then extracted in a 96-well plate using solid phase extraction on a fully automated liquid handling system. The analysis was performed using LC-MS/MS with a calibration range of 3 – 1000 ng/mL.</p></div><div><h3>Results</h3><p>The recovery rate was approximately 54–72 %, and the relative standard deviation was below 9 % for low, middle and high quality control levels. The LC-MS/MS quantification limit of 3 ng/mL is sensitive enough to detect piperaquine for up to 4–8 weeks after drug administration, which is crucial when evaluating recrudescence and drug resistance development. While different hematocrit levels can affect DBS drug measurements, the effect was minimal for piperaquine.</p></div><div><h3>Conclusion</h3><p>A sensitive LC-MS/MS method, in combination with fully automated extraction in a 96-well plate format, was developed and validated for the quantification of piperaquine in DBS. The assay was implemented in a bioanalytical laboratory for processing large-scale clinical trial samples.</p></div>\",\"PeriodicalId\":52406,\"journal\":{\"name\":\"Journal of Mass Spectrometry and Advances in the Clinical Lab\",\"volume\":\"31 \",\"pages\":\"Pages 19-26\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2667145X23000421/pdfft?md5=cdb560cd35ba8072bfcd7a8f31c71e9d&pid=1-s2.0-S2667145X23000421-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Mass Spectrometry and Advances in the Clinical Lab\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2667145X23000421\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Mass Spectrometry and Advances in the Clinical Lab","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2667145X23000421","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景疟疾是一种寄生虫病,影响着许多最贫穷的经济体,每年约有 2.41 亿人发病,62.7 万人死亡。哌喹与双氢青蒿素合用是一种有效的抗疟药物。在开始治疗后的第 7 天测量药物浓度,可以很好地预测哌喹的治疗效果。方法从干血斑(DBS)上打出三个 3.2 毫米的圆片,然后在全自动液体处理系统上使用固相萃取法在 96 孔板中进行提取。结果回收率约为 54-72%,低、中、高质控水平的相对标准偏差均低于 9%。LC-MS/MS 的定量限为 3 纳克/毫升,其灵敏度足以在用药后 4-8 周内检测到哌喹,这对于评估复发和耐药性发展至关重要。结论 开发并验证了一种灵敏的 LC-MS/MS 方法,该方法结合了 96 孔板全自动萃取技术,用于定量检测 DBS 中的哌喹。该检测方法已在生物分析实验室实施,用于处理大规模临床试验样本。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A high-throughput LC-MS/MS assay for piperaquine from dried blood spots: Improving malaria treatment in resource-limited settings

Background

Malaria is a parasitic disease that affects many of the poorest economies, resulting in approximately 241 million clinical episodes and 627,000 deaths annually. Piperaquine, when administered with dihydroartemisinin, is an effective drug against the disease. Drug concentration measurements taken on day 7 after treatment initiation have been shown to be a good predictor of therapeutic success with piperaquine. A simple capillary blood collection technique, where blood is dried onto filter paper, is especially suitable for drug studies in remote areas or resource-limited settings or when taking samples from children, toddlers, and infants.

Methods

Three 3.2 mm discs were punched out from a dried blood spot (DBS) and then extracted in a 96-well plate using solid phase extraction on a fully automated liquid handling system. The analysis was performed using LC-MS/MS with a calibration range of 3 – 1000 ng/mL.

Results

The recovery rate was approximately 54–72 %, and the relative standard deviation was below 9 % for low, middle and high quality control levels. The LC-MS/MS quantification limit of 3 ng/mL is sensitive enough to detect piperaquine for up to 4–8 weeks after drug administration, which is crucial when evaluating recrudescence and drug resistance development. While different hematocrit levels can affect DBS drug measurements, the effect was minimal for piperaquine.

Conclusion

A sensitive LC-MS/MS method, in combination with fully automated extraction in a 96-well plate format, was developed and validated for the quantification of piperaquine in DBS. The assay was implemented in a bioanalytical laboratory for processing large-scale clinical trial samples.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Mass Spectrometry and Advances in the Clinical Lab
Journal of Mass Spectrometry and Advances in the Clinical Lab Health Professions-Medical Laboratory Technology
CiteScore
4.30
自引率
18.20%
发文量
41
审稿时长
81 days
期刊最新文献
Tandem mass spectrometry of serum cholestanoic (C27) acids – Typical concentration ranges and application to the study of peroxisomal biogenesis disorders Research letter: Pilot study of a prototype fully automated mass spectrometry system for routine clinical laboratory use Method validation of an inductively coupled plasma mass spectrometry (ICP-MS) assay for the analysis of magnesium, copper and zinc in red blood cells Liquid chromatography-mass spectrometric method for the simultaneous analysis of branched-chain amino acids and their ketoacids from dried blood spot as secondary analytes for the detection of maple syrup urine disease Development and validation of an LC-MS/MS method for highly concentrated tacrolimus and cyclosporine samples prepared from pharmaceutical products to assess drug loss from feeding tubes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1