{"title":"可穿戴除颤器在心力衰竭中的作用。","authors":"Thibault Lenormand, Alexandre Bodin, Laurent Fauchier","doi":"10.1007/s11897-023-00641-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose of review: </strong>Wearable cardioverter defibrillators (WCDs) have been developed as a temporary measure for protecting patients at risk for sudden cardiac death that do not meet the indication for implantable cardioverter defibrillator (ICD), most notably in the early stages of heart failure with reduced ejection fraction before reassessment of their left ventricular ejection fraction. In this review, we report available evidence in the literature and guidelines regarding WCD use in order to try to define the role WCDs may have in heart failure.</p><p><strong>Recent findings: </strong>In the last decade, most observational studies found WCDs to be both safe and effective in terminating ventricular arrhythmias in various indications, mostly centered around heart failure with reduced ejection fraction. The only available randomized controlled trial using WCD did not however show a benefit on patients' survival. Hence, recent guidelines only recommended its use in limited indications. Recent data also suggest a possible interest of WCD in monitoring patients, a finding that may prove useful in the context of new-onset heart failure. Data regarding WCD benefit is scarce, and definitive conclusions on its utility are hard to draw. In the context of heart failure, and particularly new-onset heart failure, WCD might find a role in a global comprehensive management of the disease, both acting as an educational tool, a monitoring tool, and, most importantly, a safe and effective tool in preventing sudden cardiac death. The low level of evidence however invites caution, and the decision of prescribing a WCD needs to be individualized and thoroughly discussed with the patient whose compliance is key with this device.</p>","PeriodicalId":10830,"journal":{"name":"Current Heart Failure Reports","volume":" ","pages":"33-42"},"PeriodicalIF":3.8000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Role of the Wearable Defibrillator in Heart Failure.\",\"authors\":\"Thibault Lenormand, Alexandre Bodin, Laurent Fauchier\",\"doi\":\"10.1007/s11897-023-00641-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose of review: </strong>Wearable cardioverter defibrillators (WCDs) have been developed as a temporary measure for protecting patients at risk for sudden cardiac death that do not meet the indication for implantable cardioverter defibrillator (ICD), most notably in the early stages of heart failure with reduced ejection fraction before reassessment of their left ventricular ejection fraction. In this review, we report available evidence in the literature and guidelines regarding WCD use in order to try to define the role WCDs may have in heart failure.</p><p><strong>Recent findings: </strong>In the last decade, most observational studies found WCDs to be both safe and effective in terminating ventricular arrhythmias in various indications, mostly centered around heart failure with reduced ejection fraction. The only available randomized controlled trial using WCD did not however show a benefit on patients' survival. Hence, recent guidelines only recommended its use in limited indications. Recent data also suggest a possible interest of WCD in monitoring patients, a finding that may prove useful in the context of new-onset heart failure. Data regarding WCD benefit is scarce, and definitive conclusions on its utility are hard to draw. In the context of heart failure, and particularly new-onset heart failure, WCD might find a role in a global comprehensive management of the disease, both acting as an educational tool, a monitoring tool, and, most importantly, a safe and effective tool in preventing sudden cardiac death. The low level of evidence however invites caution, and the decision of prescribing a WCD needs to be individualized and thoroughly discussed with the patient whose compliance is key with this device.</p>\",\"PeriodicalId\":10830,\"journal\":{\"name\":\"Current Heart Failure Reports\",\"volume\":\" \",\"pages\":\"33-42\"},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2024-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Heart Failure Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s11897-023-00641-x\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/18 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Heart Failure Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s11897-023-00641-x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/18 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
The Role of the Wearable Defibrillator in Heart Failure.
Purpose of review: Wearable cardioverter defibrillators (WCDs) have been developed as a temporary measure for protecting patients at risk for sudden cardiac death that do not meet the indication for implantable cardioverter defibrillator (ICD), most notably in the early stages of heart failure with reduced ejection fraction before reassessment of their left ventricular ejection fraction. In this review, we report available evidence in the literature and guidelines regarding WCD use in order to try to define the role WCDs may have in heart failure.
Recent findings: In the last decade, most observational studies found WCDs to be both safe and effective in terminating ventricular arrhythmias in various indications, mostly centered around heart failure with reduced ejection fraction. The only available randomized controlled trial using WCD did not however show a benefit on patients' survival. Hence, recent guidelines only recommended its use in limited indications. Recent data also suggest a possible interest of WCD in monitoring patients, a finding that may prove useful in the context of new-onset heart failure. Data regarding WCD benefit is scarce, and definitive conclusions on its utility are hard to draw. In the context of heart failure, and particularly new-onset heart failure, WCD might find a role in a global comprehensive management of the disease, both acting as an educational tool, a monitoring tool, and, most importantly, a safe and effective tool in preventing sudden cardiac death. The low level of evidence however invites caution, and the decision of prescribing a WCD needs to be individualized and thoroughly discussed with the patient whose compliance is key with this device.
期刊介绍:
This journal intends to provide clear, insightful, balanced contributions by international experts that review the most important, recently published clinical findings related to the diagnosis, treatment, management, and prevention of heart failure. We accomplish this aim by appointing international authorities to serve as Section Editors in key subject areas, such as investigative, pharmacologic, and nonpharmacologic therapies, pathophysiology, and prevention. Section Editors, in turn, select topics for which leading experts contribute comprehensive review articles that emphasize new developments and recently published papers of major importance, highlighted by annotated reference lists. An international Editorial Board reviews the annual table of contents, suggests articles of special interest to their country/region, and ensures that topics are current and include emerging research. Commentaries from well-known figures in the field are also provided.