Shuichi Yoneda, Kota Murai, Yasuhide Asaumi, Teruo Noguchi
{"title":"在一例冠状动脉慢性全闭塞病例中使用 Conquest Pro 12 锐化尖端进行血管内超声引导逆行剥离和再通术","authors":"Shuichi Yoneda, Kota Murai, Yasuhide Asaumi, Teruo Noguchi","doi":"10.1016/j.crmic.2024.100007","DOIUrl":null,"url":null,"abstract":"<div><p>The Conquest Pro 12 Sharpened Tip (CP12ST) is a novel guidewire used in intervention for coronary chronic total occlusion, with strong penetration force for hard plaques. Antegrade dissection and reentry techniques using the CP12ST have been reported, and their success and safety have been established. This report describes successful retrograde dissection and reentry using the CP12ST under intravascular ultrasound guidance in a situation in which reverse controlled antegrade and retrograde tracking was difficult to perform.</p></div>","PeriodicalId":100217,"journal":{"name":"Cardiovascular Revascularization Medicine: Interesting Cases","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-01-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2950275624000030/pdfft?md5=311a84aba35eef368a12c79ca5079886&pid=1-s2.0-S2950275624000030-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Intravascular ultrasound-guided retrograde dissection and reentry using a Conquest Pro 12 Sharpened Tip in a case of coronary chronic total occlusion\",\"authors\":\"Shuichi Yoneda, Kota Murai, Yasuhide Asaumi, Teruo Noguchi\",\"doi\":\"10.1016/j.crmic.2024.100007\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The Conquest Pro 12 Sharpened Tip (CP12ST) is a novel guidewire used in intervention for coronary chronic total occlusion, with strong penetration force for hard plaques. Antegrade dissection and reentry techniques using the CP12ST have been reported, and their success and safety have been established. This report describes successful retrograde dissection and reentry using the CP12ST under intravascular ultrasound guidance in a situation in which reverse controlled antegrade and retrograde tracking was difficult to perform.</p></div>\",\"PeriodicalId\":100217,\"journal\":{\"name\":\"Cardiovascular Revascularization Medicine: Interesting Cases\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2950275624000030/pdfft?md5=311a84aba35eef368a12c79ca5079886&pid=1-s2.0-S2950275624000030-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiovascular Revascularization Medicine: Interesting Cases\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2950275624000030\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular Revascularization Medicine: Interesting Cases","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2950275624000030","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
Conquest Pro 12 磨尖导丝(CP12ST)是一种用于冠状动脉慢性全闭塞介入治疗的新型导丝,对硬斑块具有很强的穿透力。使用 CP12ST 的前行剥离和再入技术已有报道,其成功性和安全性已得到证实。本报告描述了在血管内超声引导下使用 CP12ST 成功进行逆行剥离和再通的情况,在这种情况下很难进行反向控制的逆行和顺行追踪。
Intravascular ultrasound-guided retrograde dissection and reentry using a Conquest Pro 12 Sharpened Tip in a case of coronary chronic total occlusion
The Conquest Pro 12 Sharpened Tip (CP12ST) is a novel guidewire used in intervention for coronary chronic total occlusion, with strong penetration force for hard plaques. Antegrade dissection and reentry techniques using the CP12ST have been reported, and their success and safety have been established. This report describes successful retrograde dissection and reentry using the CP12ST under intravascular ultrasound guidance in a situation in which reverse controlled antegrade and retrograde tracking was difficult to perform.