[足背动脉穿刺前侧支血流的光容积脉搏波评价]。

M Bund, B Panning
{"title":"[足背动脉穿刺前侧支血流的光容积脉搏波评价]。","authors":"M Bund,&nbsp;B Panning","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Prior to cannulation of the dorsalis pedis artery the collateral circulation through the plantar arch should be examined to evaluate the consequence of an occlusion of this artery. Since the performance of the Allen's test is impossible for assessment of the plantar arch, another suitable technique has to be chosen. We selected the photoelectric plethysmography. Toe pulses were recorded with photoelectric plethysmography in 20 neurosurgical patients. The pulse amplitudes were measured before and during successive compression of the dorsalis pedis and the posterior tibial artery. Obvious decrease or absence of the pulse wave during compression of the dorsalis pedis artery is indicating an inadequate collateral circulation and cannulation of this artery seems not to be safe. In our study this occurred in 4 of 32 examined feet (12.5 percent). The photoelectric plethysmography has proved to be a simple and accurate means for assessment of collateral circulation.</p>","PeriodicalId":7813,"journal":{"name":"Anasthesie, Intensivtherapie, Notfallmedizin","volume":"24 5","pages":"309-11"},"PeriodicalIF":0.0000,"publicationDate":"1989-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Photoplethysmography evaluation of collateral blood flow before puncture of the dorsalis pedis artery].\",\"authors\":\"M Bund,&nbsp;B Panning\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Prior to cannulation of the dorsalis pedis artery the collateral circulation through the plantar arch should be examined to evaluate the consequence of an occlusion of this artery. Since the performance of the Allen's test is impossible for assessment of the plantar arch, another suitable technique has to be chosen. We selected the photoelectric plethysmography. Toe pulses were recorded with photoelectric plethysmography in 20 neurosurgical patients. The pulse amplitudes were measured before and during successive compression of the dorsalis pedis and the posterior tibial artery. Obvious decrease or absence of the pulse wave during compression of the dorsalis pedis artery is indicating an inadequate collateral circulation and cannulation of this artery seems not to be safe. In our study this occurred in 4 of 32 examined feet (12.5 percent). The photoelectric plethysmography has proved to be a simple and accurate means for assessment of collateral circulation.</p>\",\"PeriodicalId\":7813,\"journal\":{\"name\":\"Anasthesie, Intensivtherapie, Notfallmedizin\",\"volume\":\"24 5\",\"pages\":\"309-11\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Anasthesie, Intensivtherapie, Notfallmedizin\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anasthesie, Intensivtherapie, Notfallmedizin","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在足背动脉插管之前,应检查通过足底弓的侧支循环,以评估该动脉闭塞的后果。由于Allen试验的性能无法评估足底弓,因此必须选择另一种合适的技术。我们选择了光电体积描记仪。对20例神经外科患者用光电体积脉搏波仪记录足部脉搏。在连续压迫足背肌和胫骨后动脉之前和过程中测量脉搏幅值。足背动脉受压时脉搏波明显减少或消失,提示侧支循环不足,该动脉插管似乎不安全。在我们的研究中,32只被检查的脚中有4只发生了这种情况(12.5%)。光电容积脉搏波是一种简单、准确的评价侧支循环的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Photoplethysmography evaluation of collateral blood flow before puncture of the dorsalis pedis artery].

Prior to cannulation of the dorsalis pedis artery the collateral circulation through the plantar arch should be examined to evaluate the consequence of an occlusion of this artery. Since the performance of the Allen's test is impossible for assessment of the plantar arch, another suitable technique has to be chosen. We selected the photoelectric plethysmography. Toe pulses were recorded with photoelectric plethysmography in 20 neurosurgical patients. The pulse amplitudes were measured before and during successive compression of the dorsalis pedis and the posterior tibial artery. Obvious decrease or absence of the pulse wave during compression of the dorsalis pedis artery is indicating an inadequate collateral circulation and cannulation of this artery seems not to be safe. In our study this occurred in 4 of 32 examined feet (12.5 percent). The photoelectric plethysmography has proved to be a simple and accurate means for assessment of collateral circulation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[The measurement of extravascular lung water--significant in the follow-up of ARDS?]. [Fat emulsions in parenteral feeding following liver transplantation. I. Effect on the recovery of RES function in the transplant]. [The effect of selective decontamination on nosocomial infections, their causative agents and antibiotic resistance in long-term intubated intensive care patients]. [Hypothermia and polytrauma. A case report (28 degrees C)]. [The present situation and developing trends in intensive medicine].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1