José J Arcas-Bellas, Roberto Siljeström, Cristina Sánchez, Ana González, Javier García-Fernández
{"title":"在同种异位肝移植手术中使用经食道超声心动图:简化手术过程。","authors":"José J Arcas-Bellas, Roberto Siljeström, Cristina Sánchez, Ana González, Javier García-Fernández","doi":"10.1097/TXD.0000000000001564","DOIUrl":null,"url":null,"abstract":"<p><p>The intraoperative management of patients undergoing orthotopic liver transplantation (OLT) is influenced by the cardiovascular manifestations typically found in the context of end-stage liver disease, by the presence of concomitant cardiovascular disease, and by the significant hemodynamic changes that occur during surgery. Hypotension and intraoperative blood pressure fluctuations during OLT are associated with liver graft dysfunction, acute kidney failure, and increased risk of 30-d mortality. Patients also frequently present hemodynamic instability due to various causes, including cardiac arrest. Recent evidence has shown transesophageal echocardiography (TEE) to be a useful minimally invasive monitoring tool in patients undergoing OLT that gives valuable real-time information on biventricular function and volume status and can help to detect OLT-specific complications or situations. TEE also facilitates rapid diagnosis of life-threatening conditions in each stage of OLT, which is difficult to identify with other types of monitoring commonly used. Although there is no consensus on the best approach to intraoperative monitoring in these patients, intraoperative TEE is safe and useful and should be recommended during OLT, according to experts, for assessing hemodynamic changes, identifying possible complications, and guiding treatment with fluids and inotropes to achieve optimal patient care.</p>","PeriodicalId":23225,"journal":{"name":"Transplantation Direct","volume":"10 2","pages":"e1564"},"PeriodicalIF":1.9000,"publicationDate":"2024-01-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10810591/pdf/","citationCount":"0","resultStr":"{\"title\":\"Use of Transesophageal Echocardiography During Orthotopic Liver Transplantation: Simplifying the Procedure.\",\"authors\":\"José J Arcas-Bellas, Roberto Siljeström, Cristina Sánchez, Ana González, Javier García-Fernández\",\"doi\":\"10.1097/TXD.0000000000001564\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The intraoperative management of patients undergoing orthotopic liver transplantation (OLT) is influenced by the cardiovascular manifestations typically found in the context of end-stage liver disease, by the presence of concomitant cardiovascular disease, and by the significant hemodynamic changes that occur during surgery. Hypotension and intraoperative blood pressure fluctuations during OLT are associated with liver graft dysfunction, acute kidney failure, and increased risk of 30-d mortality. Patients also frequently present hemodynamic instability due to various causes, including cardiac arrest. Recent evidence has shown transesophageal echocardiography (TEE) to be a useful minimally invasive monitoring tool in patients undergoing OLT that gives valuable real-time information on biventricular function and volume status and can help to detect OLT-specific complications or situations. TEE also facilitates rapid diagnosis of life-threatening conditions in each stage of OLT, which is difficult to identify with other types of monitoring commonly used. Although there is no consensus on the best approach to intraoperative monitoring in these patients, intraoperative TEE is safe and useful and should be recommended during OLT, according to experts, for assessing hemodynamic changes, identifying possible complications, and guiding treatment with fluids and inotropes to achieve optimal patient care.</p>\",\"PeriodicalId\":23225,\"journal\":{\"name\":\"Transplantation Direct\",\"volume\":\"10 2\",\"pages\":\"e1564\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-01-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10810591/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Transplantation Direct\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/TXD.0000000000001564\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"TRANSPLANTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transplantation Direct","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/TXD.0000000000001564","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"TRANSPLANTATION","Score":null,"Total":0}
Use of Transesophageal Echocardiography During Orthotopic Liver Transplantation: Simplifying the Procedure.
The intraoperative management of patients undergoing orthotopic liver transplantation (OLT) is influenced by the cardiovascular manifestations typically found in the context of end-stage liver disease, by the presence of concomitant cardiovascular disease, and by the significant hemodynamic changes that occur during surgery. Hypotension and intraoperative blood pressure fluctuations during OLT are associated with liver graft dysfunction, acute kidney failure, and increased risk of 30-d mortality. Patients also frequently present hemodynamic instability due to various causes, including cardiac arrest. Recent evidence has shown transesophageal echocardiography (TEE) to be a useful minimally invasive monitoring tool in patients undergoing OLT that gives valuable real-time information on biventricular function and volume status and can help to detect OLT-specific complications or situations. TEE also facilitates rapid diagnosis of life-threatening conditions in each stage of OLT, which is difficult to identify with other types of monitoring commonly used. Although there is no consensus on the best approach to intraoperative monitoring in these patients, intraoperative TEE is safe and useful and should be recommended during OLT, according to experts, for assessing hemodynamic changes, identifying possible complications, and guiding treatment with fluids and inotropes to achieve optimal patient care.