Michael V. Brown , Arash Badiei , Matthew Arnold , Hubertus Jersmann , Thomas Sullivan , David Fielding , Phan Nguyen
{"title":"锥形束计算机断层扫描结合径向支气管内超声诊断周围肺结节的诊断率:系统回顾与元分析","authors":"Michael V. Brown , Arash Badiei , Matthew Arnold , Hubertus Jersmann , Thomas Sullivan , David Fielding , Phan Nguyen","doi":"10.1016/j.chpulm.2024.100037","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Identification of peripheral pulmonary nodules (PPNs) is becoming increasingly common with modern imaging and lung cancer screening programs. Navigational bronchoscopy has been developed to augment the diagnostic yield of sampling these nodules. Cone beam CT (CBCT) scan is one navigational tool which can be used alongside the historical criterion standard of fluoroscopy and radial endobronchial ultrasound (r-EBUS).</p></div><div><h3>Research Question</h3><p>What is the diagnostic yield and safety profile of combining CBCT scan with r-EBUS for the diagnosis of PPNs?</p></div><div><h3>Study Design and Methods</h3><p>Embase, PubMed, and Cochrane Central Register of Controlled Trials were searched in March 2023. Eligible studies used CBCT scan with r-EBUS as the primary navigation technique. The primary outcome, diagnostic yield, was analyzed using random effects meta-analysis. Additional subgroup analysis was based on the use of additional navigational technologies. Risk of bias was assessed using the Critical Appraisal Skills Programme tool for diagnostic studies. The Grading of Recommendations Assessment, Development, and Evaluation tool was used to assess the quality of outcomes.</p></div><div><h3>Results</h3><p>Fourteen studies (865 patients and 882 lesions) were included. The risk of bias was significant as assessed using the Critical Appraisal Skills Programme tool, which identified multiple confounders. The pooled diagnostic yield of combined CBCT scan and r-EBUS-guided biopsy for the diagnosis of PPNs was 80% (95% CI, 76%-84%). Subgroup analysis of diagnostic yield for CBCT scan and r-EBUS alone was 80% (95% CI, 76%-83%). The diagnostic yield of CBCT scan and r-EBUS combined with additional navigational technology (electromagnetic navigational bronchoscopy, virtual bronchoscopic navigation, and robotic-assisted bronchoscopy) was 80% (95% CI, 73%-87%). The quality of outcomes was assessed as low to very low using the Grading of Recommendations Assessment, Development, and Evaluation tool. There was a 2.01% pneumothorax rate and 1.08% bleeding rate. Although heterogeneously reported, the total radiation dose was between 19.59 and 85.9 Gy.cm<sup>2</sup>, resulting in an approximate effective dose range of 3.1 to 13.8 mSv.</p></div><div><h3>Interpretation</h3><p>CBCT scan and r-EBUS for the diagnosis of PPNs has a high diagnostic yield and acceptable safety profile. Studies showed moderate heterogeneity with significant bias; hence, generalizability of the study is limited and further prospective trials are required.</p></div><div><h3>Clinical Trial Registration</h3><p>PROSPERO; No.: CRD42023410221; URL: <span>https://www.crd.york.ac.uk/prospero/</span><svg><path></path></svg>.</p></div>","PeriodicalId":94286,"journal":{"name":"CHEST pulmonary","volume":"2 2","pages":"Article 100037"},"PeriodicalIF":0.0000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2949789224000035/pdfft?md5=bc2aa3bf83825252aa53afcfceb99568&pid=1-s2.0-S2949789224000035-main.pdf","citationCount":"0","resultStr":"{\"title\":\"The Diagnostic Yield of Cone Beam CT Combined With Radial-Endobronchial Ultrasound for the Diagnosis of Peripheral Pulmonary Nodules\",\"authors\":\"Michael V. Brown , Arash Badiei , Matthew Arnold , Hubertus Jersmann , Thomas Sullivan , David Fielding , Phan Nguyen\",\"doi\":\"10.1016/j.chpulm.2024.100037\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Identification of peripheral pulmonary nodules (PPNs) is becoming increasingly common with modern imaging and lung cancer screening programs. Navigational bronchoscopy has been developed to augment the diagnostic yield of sampling these nodules. Cone beam CT (CBCT) scan is one navigational tool which can be used alongside the historical criterion standard of fluoroscopy and radial endobronchial ultrasound (r-EBUS).</p></div><div><h3>Research Question</h3><p>What is the diagnostic yield and safety profile of combining CBCT scan with r-EBUS for the diagnosis of PPNs?</p></div><div><h3>Study Design and Methods</h3><p>Embase, PubMed, and Cochrane Central Register of Controlled Trials were searched in March 2023. Eligible studies used CBCT scan with r-EBUS as the primary navigation technique. The primary outcome, diagnostic yield, was analyzed using random effects meta-analysis. Additional subgroup analysis was based on the use of additional navigational technologies. Risk of bias was assessed using the Critical Appraisal Skills Programme tool for diagnostic studies. The Grading of Recommendations Assessment, Development, and Evaluation tool was used to assess the quality of outcomes.</p></div><div><h3>Results</h3><p>Fourteen studies (865 patients and 882 lesions) were included. The risk of bias was significant as assessed using the Critical Appraisal Skills Programme tool, which identified multiple confounders. The pooled diagnostic yield of combined CBCT scan and r-EBUS-guided biopsy for the diagnosis of PPNs was 80% (95% CI, 76%-84%). Subgroup analysis of diagnostic yield for CBCT scan and r-EBUS alone was 80% (95% CI, 76%-83%). The diagnostic yield of CBCT scan and r-EBUS combined with additional navigational technology (electromagnetic navigational bronchoscopy, virtual bronchoscopic navigation, and robotic-assisted bronchoscopy) was 80% (95% CI, 73%-87%). The quality of outcomes was assessed as low to very low using the Grading of Recommendations Assessment, Development, and Evaluation tool. There was a 2.01% pneumothorax rate and 1.08% bleeding rate. Although heterogeneously reported, the total radiation dose was between 19.59 and 85.9 Gy.cm<sup>2</sup>, resulting in an approximate effective dose range of 3.1 to 13.8 mSv.</p></div><div><h3>Interpretation</h3><p>CBCT scan and r-EBUS for the diagnosis of PPNs has a high diagnostic yield and acceptable safety profile. Studies showed moderate heterogeneity with significant bias; hence, generalizability of the study is limited and further prospective trials are required.</p></div><div><h3>Clinical Trial Registration</h3><p>PROSPERO; No.: CRD42023410221; URL: <span>https://www.crd.york.ac.uk/prospero/</span><svg><path></path></svg>.</p></div>\",\"PeriodicalId\":94286,\"journal\":{\"name\":\"CHEST pulmonary\",\"volume\":\"2 2\",\"pages\":\"Article 100037\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2949789224000035/pdfft?md5=bc2aa3bf83825252aa53afcfceb99568&pid=1-s2.0-S2949789224000035-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"CHEST pulmonary\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2949789224000035\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"CHEST pulmonary","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2949789224000035","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The Diagnostic Yield of Cone Beam CT Combined With Radial-Endobronchial Ultrasound for the Diagnosis of Peripheral Pulmonary Nodules
Background
Identification of peripheral pulmonary nodules (PPNs) is becoming increasingly common with modern imaging and lung cancer screening programs. Navigational bronchoscopy has been developed to augment the diagnostic yield of sampling these nodules. Cone beam CT (CBCT) scan is one navigational tool which can be used alongside the historical criterion standard of fluoroscopy and radial endobronchial ultrasound (r-EBUS).
Research Question
What is the diagnostic yield and safety profile of combining CBCT scan with r-EBUS for the diagnosis of PPNs?
Study Design and Methods
Embase, PubMed, and Cochrane Central Register of Controlled Trials were searched in March 2023. Eligible studies used CBCT scan with r-EBUS as the primary navigation technique. The primary outcome, diagnostic yield, was analyzed using random effects meta-analysis. Additional subgroup analysis was based on the use of additional navigational technologies. Risk of bias was assessed using the Critical Appraisal Skills Programme tool for diagnostic studies. The Grading of Recommendations Assessment, Development, and Evaluation tool was used to assess the quality of outcomes.
Results
Fourteen studies (865 patients and 882 lesions) were included. The risk of bias was significant as assessed using the Critical Appraisal Skills Programme tool, which identified multiple confounders. The pooled diagnostic yield of combined CBCT scan and r-EBUS-guided biopsy for the diagnosis of PPNs was 80% (95% CI, 76%-84%). Subgroup analysis of diagnostic yield for CBCT scan and r-EBUS alone was 80% (95% CI, 76%-83%). The diagnostic yield of CBCT scan and r-EBUS combined with additional navigational technology (electromagnetic navigational bronchoscopy, virtual bronchoscopic navigation, and robotic-assisted bronchoscopy) was 80% (95% CI, 73%-87%). The quality of outcomes was assessed as low to very low using the Grading of Recommendations Assessment, Development, and Evaluation tool. There was a 2.01% pneumothorax rate and 1.08% bleeding rate. Although heterogeneously reported, the total radiation dose was between 19.59 and 85.9 Gy.cm2, resulting in an approximate effective dose range of 3.1 to 13.8 mSv.
Interpretation
CBCT scan and r-EBUS for the diagnosis of PPNs has a high diagnostic yield and acceptable safety profile. Studies showed moderate heterogeneity with significant bias; hence, generalizability of the study is limited and further prospective trials are required.