对选定材料--树脂改性玻璃离子水泥(Vitremer)和纳米混合复合材料(Tetric EvoCeram)--的氟离子释放情况进行体外检测。

IF 0.8 4区 医学 Q4 BIOPHYSICS Acta of bioengineering and biomechanics Pub Date : 2023-01-01
Piotr Kosior, Sylwia Klimas, Anna Nikodem, Justyna Wolicka, Dorota Diakowska, Adam Watras, Rafał J Wiglusz, Maciej Dobrzyński
{"title":"对选定材料--树脂改性玻璃离子水泥(Vitremer)和纳米混合复合材料(Tetric EvoCeram)--的氟离子释放情况进行体外检测。","authors":"Piotr Kosior, Sylwia Klimas, Anna Nikodem, Justyna Wolicka, Dorota Diakowska, Adam Watras, Rafał J Wiglusz, Maciej Dobrzyński","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to examine a short-term fluoride ions release from selected materials - resin-modified glass ionomer -Vitremer (3M ESPE) and nanohybrid universal composite - Tetric EvoCeram (IvoclarVivadent). Release of fluoride ions [µg/mm2 /h] from Tetric EvoCeram and Vitremer into nine environments (artificial saliva - AS, deionized water and 0.9% NaCl) differing in composition of the solution and pH was determined. Six samples were prepared for each solution. In the short-term study, the measurements were taken after 1, 3, 24, 48, 72 and 168 hours. The cumulative values as well as levels of fluoride ions released at concrete time intervals were compared. Within 7 days (168 hours), both materials showed variable levels of fluoride ions release. The highest value of fluoride ions release from nanohybrid Tetric EvoCeram material was reported in deionized water (8) after 24 hours (1.550 ± 0.014 [µg/mm2/h]) and the lowest value was read in the artificial saliva AS pH 7.5 (5) after 1 hour (0.022 ± 0.001 [µg/mm2/h]). What's more, the highest value of F- release from Vitremer was found in deionized water (8) after 168 hours of immersion (24.021 ± 2.280 [µg/mm2/h]) and the lowest value was in the artificial saliva AS (without Ca2+) pH 4.5 (6) (0.303 ± 0.249 [µg/mm2/h]) after 168 hours. Cumulated release of F- after 7 days was notably higher from resin- modified glass ionomer material - Vitremer in all artificial saliva solutions (1-7) which imitated the environment of oral cavity. Therefore, we can assume that Vitremer has better remineralization potential and it may constitute a more effective method of tooth decay prevention.</p>","PeriodicalId":6897,"journal":{"name":"Acta of bioengineering and biomechanics","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An in vitro examination of fluoride ions release from selected materials - resin-modified glass-ionomer cement (Vitremer) and nanohybrid composite material (Tetric EvoCeram).\",\"authors\":\"Piotr Kosior, Sylwia Klimas, Anna Nikodem, Justyna Wolicka, Dorota Diakowska, Adam Watras, Rafał J Wiglusz, Maciej Dobrzyński\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The aim of this study was to examine a short-term fluoride ions release from selected materials - resin-modified glass ionomer -Vitremer (3M ESPE) and nanohybrid universal composite - Tetric EvoCeram (IvoclarVivadent). Release of fluoride ions [µg/mm2 /h] from Tetric EvoCeram and Vitremer into nine environments (artificial saliva - AS, deionized water and 0.9% NaCl) differing in composition of the solution and pH was determined. Six samples were prepared for each solution. In the short-term study, the measurements were taken after 1, 3, 24, 48, 72 and 168 hours. The cumulative values as well as levels of fluoride ions released at concrete time intervals were compared. Within 7 days (168 hours), both materials showed variable levels of fluoride ions release. The highest value of fluoride ions release from nanohybrid Tetric EvoCeram material was reported in deionized water (8) after 24 hours (1.550 ± 0.014 [µg/mm2/h]) and the lowest value was read in the artificial saliva AS pH 7.5 (5) after 1 hour (0.022 ± 0.001 [µg/mm2/h]). What's more, the highest value of F- release from Vitremer was found in deionized water (8) after 168 hours of immersion (24.021 ± 2.280 [µg/mm2/h]) and the lowest value was in the artificial saliva AS (without Ca2+) pH 4.5 (6) (0.303 ± 0.249 [µg/mm2/h]) after 168 hours. Cumulated release of F- after 7 days was notably higher from resin- modified glass ionomer material - Vitremer in all artificial saliva solutions (1-7) which imitated the environment of oral cavity. Therefore, we can assume that Vitremer has better remineralization potential and it may constitute a more effective method of tooth decay prevention.</p>\",\"PeriodicalId\":6897,\"journal\":{\"name\":\"Acta of bioengineering and biomechanics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta of bioengineering and biomechanics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta of bioengineering and biomechanics","FirstCategoryId":"5","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

摘要

本研究的目的是检测所选材料--树脂改性玻璃离聚体 Vitremer(3M ESPE)和纳米混合通用复合材料--Tetric EvoCeram(IvoclarVivadent)的氟离子短期释放情况。测定了 Tetric EvoCeram 和 Vitremer 在九种环境(人工唾液 - AS、去离子水和 0.9% 氯化钠)中的氟离子释放量[µg/mm2 /h],这些环境的溶液成分和 pH 值各不相同。每种溶液均制备了六个样品。在短期研究中,分别在 1、3、24、48、72 和 168 小时后进行测量。比较了累积值以及在具体时间间隔内释放的氟离子水平。在 7 天(168 小时)内,两种材料的氟离子释放量各不相同。24 小时后,纳米杂化 Tetric EvoCeram 材料在去离子水中的氟离子释放值最高(8)(1.550 ± 0.014 [µg/mm2/h]),1 小时后,在 pH 值为 7.5 的人工唾液中的氟离子释放值最低(5)(0.022 ± 0.001 [µg/mm2/h])。此外,浸泡 168 小时后,Vitremer 在去离子水(8)中的 F- 释放值最高(24.021 ± 2.280 [µg/mm2/h]),最低值出现在 pH 值为 4.5 (6) 的人工唾液 AS(不含 Ca2+)中(0.303 ± 0.249 [µg/mm2/h])。在模仿口腔环境的所有人工唾液溶液(1-7)中,7 天后树脂改性玻璃离聚体材料 - Vitremer 的 F- 累积释放量明显更高。因此,我们可以认为 Vitremer 具有更好的再矿化潜力,是一种更有效的蛀牙预防方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
An in vitro examination of fluoride ions release from selected materials - resin-modified glass-ionomer cement (Vitremer) and nanohybrid composite material (Tetric EvoCeram).

The aim of this study was to examine a short-term fluoride ions release from selected materials - resin-modified glass ionomer -Vitremer (3M ESPE) and nanohybrid universal composite - Tetric EvoCeram (IvoclarVivadent). Release of fluoride ions [µg/mm2 /h] from Tetric EvoCeram and Vitremer into nine environments (artificial saliva - AS, deionized water and 0.9% NaCl) differing in composition of the solution and pH was determined. Six samples were prepared for each solution. In the short-term study, the measurements were taken after 1, 3, 24, 48, 72 and 168 hours. The cumulative values as well as levels of fluoride ions released at concrete time intervals were compared. Within 7 days (168 hours), both materials showed variable levels of fluoride ions release. The highest value of fluoride ions release from nanohybrid Tetric EvoCeram material was reported in deionized water (8) after 24 hours (1.550 ± 0.014 [µg/mm2/h]) and the lowest value was read in the artificial saliva AS pH 7.5 (5) after 1 hour (0.022 ± 0.001 [µg/mm2/h]). What's more, the highest value of F- release from Vitremer was found in deionized water (8) after 168 hours of immersion (24.021 ± 2.280 [µg/mm2/h]) and the lowest value was in the artificial saliva AS (without Ca2+) pH 4.5 (6) (0.303 ± 0.249 [µg/mm2/h]) after 168 hours. Cumulated release of F- after 7 days was notably higher from resin- modified glass ionomer material - Vitremer in all artificial saliva solutions (1-7) which imitated the environment of oral cavity. Therefore, we can assume that Vitremer has better remineralization potential and it may constitute a more effective method of tooth decay prevention.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta of bioengineering and biomechanics
Acta of bioengineering and biomechanics BIOPHYSICS-ENGINEERING, BIOMEDICAL
CiteScore
2.10
自引率
10.00%
发文量
0
期刊介绍: Acta of Bioengineering and Biomechanics is a platform allowing presentation of investigations results, exchange of ideas and experiences among researchers with technical and medical background. Papers published in Acta of Bioengineering and Biomechanics may cover a wide range of topics in biomechanics, including, but not limited to: Tissue Biomechanics, Orthopedic Biomechanics, Biomaterials, Sport Biomechanics.
期刊最新文献
Characterization of biomaterials with reference to biocompatibility dedicated for patient-specific finger implants Dynamic-passive correction of hallux valgus and associated static foot deformities Quantitative evaluation of stereoscopic augmented reality visualization using an optical see-through head-mounted display Analysis of Muscle Activity During Rowing Stroke Phases Experimental research of energy absorbing structures within helmet samples made with the additive manufacturing method - preliminary study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1