{"title":"将硝酸盐作为相变材料用于中温潜热式储罐的电荷评估","authors":"Ismail, Y. I. Widodo, R. A. Rahman","doi":"10.2478/lpts-2024-0006","DOIUrl":null,"url":null,"abstract":"\n The present study assesses the heat characteristic of the nitrate-salt mixture as a phase change material (PCM) for a medium-temperature latent storage system (LSS). Two binary and ternary mixtures are evaluated, which demonstrate different thermal behaviour. The highest melting and latent heat capacity is obtained by KNO3(0.4)/NaNO3(0.6) at 223.8 °C and 161.5 J/g. However, it has a higher supercooling degree with a partial phase transition between 217.6 °C and 251.5 °C, making it unfeasible for a medium-temperature LSS tank. The ternary mixture (TM) with NaNO2(0.4)/KNO2(0.53)/NaNO3(0.7) demonstrates a stable phase transition with minimum partial phase transition (22.1 °C) and suitable heat of fusion (98.1 J/g). Further evaluation through static thermal profiling demonstrates that the TM has a notable performance during solid-sensible charge with a charge level indicator (CLI) around 45.3 %–49.1 %. The TM can be charged up to 85.7 % until the end stage of the phase transition. It promotes a better storage capacity with suitable performance since the system can be charged effectively at a suitable temperature range (< 160 °C) for various applications. The micrograph observation indicates some dispersed particles and local agglomeration, which makes phase stabilization as an advantageous method to promote a stable phase change process. The TM can be considered a suitable PCM for a medium-temperature LSS tank that allows for a better solar thermal renewable system operation.","PeriodicalId":0,"journal":{"name":"","volume":"97 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Charge Assessment for Nitrate-Based Salt as a Phase Change Material for a Medium-Temperature Latent Storage Tank\",\"authors\":\"Ismail, Y. I. Widodo, R. A. Rahman\",\"doi\":\"10.2478/lpts-2024-0006\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n The present study assesses the heat characteristic of the nitrate-salt mixture as a phase change material (PCM) for a medium-temperature latent storage system (LSS). Two binary and ternary mixtures are evaluated, which demonstrate different thermal behaviour. The highest melting and latent heat capacity is obtained by KNO3(0.4)/NaNO3(0.6) at 223.8 °C and 161.5 J/g. However, it has a higher supercooling degree with a partial phase transition between 217.6 °C and 251.5 °C, making it unfeasible for a medium-temperature LSS tank. The ternary mixture (TM) with NaNO2(0.4)/KNO2(0.53)/NaNO3(0.7) demonstrates a stable phase transition with minimum partial phase transition (22.1 °C) and suitable heat of fusion (98.1 J/g). Further evaluation through static thermal profiling demonstrates that the TM has a notable performance during solid-sensible charge with a charge level indicator (CLI) around 45.3 %–49.1 %. The TM can be charged up to 85.7 % until the end stage of the phase transition. It promotes a better storage capacity with suitable performance since the system can be charged effectively at a suitable temperature range (< 160 °C) for various applications. The micrograph observation indicates some dispersed particles and local agglomeration, which makes phase stabilization as an advantageous method to promote a stable phase change process. The TM can be considered a suitable PCM for a medium-temperature LSS tank that allows for a better solar thermal renewable system operation.\",\"PeriodicalId\":0,\"journal\":{\"name\":\"\",\"volume\":\"97 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0,\"publicationDate\":\"2024-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/lpts-2024-0006\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/lpts-2024-0006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Charge Assessment for Nitrate-Based Salt as a Phase Change Material for a Medium-Temperature Latent Storage Tank
The present study assesses the heat characteristic of the nitrate-salt mixture as a phase change material (PCM) for a medium-temperature latent storage system (LSS). Two binary and ternary mixtures are evaluated, which demonstrate different thermal behaviour. The highest melting and latent heat capacity is obtained by KNO3(0.4)/NaNO3(0.6) at 223.8 °C and 161.5 J/g. However, it has a higher supercooling degree with a partial phase transition between 217.6 °C and 251.5 °C, making it unfeasible for a medium-temperature LSS tank. The ternary mixture (TM) with NaNO2(0.4)/KNO2(0.53)/NaNO3(0.7) demonstrates a stable phase transition with minimum partial phase transition (22.1 °C) and suitable heat of fusion (98.1 J/g). Further evaluation through static thermal profiling demonstrates that the TM has a notable performance during solid-sensible charge with a charge level indicator (CLI) around 45.3 %–49.1 %. The TM can be charged up to 85.7 % until the end stage of the phase transition. It promotes a better storage capacity with suitable performance since the system can be charged effectively at a suitable temperature range (< 160 °C) for various applications. The micrograph observation indicates some dispersed particles and local agglomeration, which makes phase stabilization as an advantageous method to promote a stable phase change process. The TM can be considered a suitable PCM for a medium-temperature LSS tank that allows for a better solar thermal renewable system operation.