用于筛查先天性心脏病的脉搏氧饱和度测试:系统综述。

Revista da Escola de Enfermagem da U S P Pub Date : 2024-03-01 eCollection Date: 2024-01-01 DOI:10.1590/1980-220X-REEUSP-2023-0215en
Gabrielle Freitas Saganski, Márcia Helena de Souza Freire, Wendel Mombaque Dos Santos
{"title":"用于筛查先天性心脏病的脉搏氧饱和度测试:系统综述。","authors":"Gabrielle Freitas Saganski, Márcia Helena de Souza Freire, Wendel Mombaque Dos Santos","doi":"10.1590/1980-220X-REEUSP-2023-0215en","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To determine the accuracy of the Pulse Oximetry Test (POT) in screening for Congenital Heart Diseases (CHD) in newborns in the first 48 hours of life.</p><p><strong>Method: </strong>Systematic review of diagnostic test accuracy with meta-analysis. The selection of studies was carried out in June 2021. Studies were selected with newborns, in a hospital or home environment, without a previous diagnosis of CHD, regardless of gestational age at birth, who underwent POT within the first 48 hours after birth. Registration on the PROSPERO platform - CRD42021256286.</p><p><strong>Results: </strong>Twenty-nine studies were included, totaling a population of 388,491 newborns. POT demonstrated sensitivity of 47% (95% CI: 43% to 50%) and specificity of 98% (95% CI: 98% to 98%). Subgroup analyses were carried out according to the different testing period, inclusion of retests in protocols and population of premature newborns.</p><p><strong>Conclusion: </strong>POT is a test with moderate sensitivity and high specificity. It is more effective when carried out within 24h - 48h of birth; in protocols that present retests, within two hours after the first measurement. It does not show satisfactory effectiveness for premature newborns.</p>","PeriodicalId":94195,"journal":{"name":"Revista da Escola de Enfermagem da U S P","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10906467/pdf/","citationCount":"0","resultStr":"{\"title\":\"Pulse oximetry test for screening congenital heart diseases: a systematic review.\",\"authors\":\"Gabrielle Freitas Saganski, Márcia Helena de Souza Freire, Wendel Mombaque Dos Santos\",\"doi\":\"10.1590/1980-220X-REEUSP-2023-0215en\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To determine the accuracy of the Pulse Oximetry Test (POT) in screening for Congenital Heart Diseases (CHD) in newborns in the first 48 hours of life.</p><p><strong>Method: </strong>Systematic review of diagnostic test accuracy with meta-analysis. The selection of studies was carried out in June 2021. Studies were selected with newborns, in a hospital or home environment, without a previous diagnosis of CHD, regardless of gestational age at birth, who underwent POT within the first 48 hours after birth. Registration on the PROSPERO platform - CRD42021256286.</p><p><strong>Results: </strong>Twenty-nine studies were included, totaling a population of 388,491 newborns. POT demonstrated sensitivity of 47% (95% CI: 43% to 50%) and specificity of 98% (95% CI: 98% to 98%). Subgroup analyses were carried out according to the different testing period, inclusion of retests in protocols and population of premature newborns.</p><p><strong>Conclusion: </strong>POT is a test with moderate sensitivity and high specificity. It is more effective when carried out within 24h - 48h of birth; in protocols that present retests, within two hours after the first measurement. It does not show satisfactory effectiveness for premature newborns.</p>\",\"PeriodicalId\":94195,\"journal\":{\"name\":\"Revista da Escola de Enfermagem da U S P\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10906467/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista da Escola de Enfermagem da U S P\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1590/1980-220X-REEUSP-2023-0215en\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista da Escola de Enfermagem da U S P","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/1980-220X-REEUSP-2023-0215en","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的确定脉搏氧饱和度测试(POT)在新生儿出生后 48 小时内筛查先天性心脏病(CHD)的准确性:方法:对诊断测试的准确性进行系统回顾和荟萃分析。研究的筛选于 2021 年 6 月进行。研究对象为在医院或家庭环境中出生的新生儿,既往未被诊断出患有先天性心脏病,无论出生时的胎龄如何,均在出生后 48 小时内接受了 POT 检查。在 PROSPERO 平台注册 - CRD42021256286:结果:共纳入 29 项研究,涉及 388 491 名新生儿。POT的灵敏度为47%(95% CI:43%至50%),特异度为98%(95% CI:98%至98%)。根据不同的检测时间、方案中是否包含复检以及早产新生儿人群进行了分组分析:POT是一种灵敏度适中、特异性较高的检测方法。结论:POT 是一种灵敏度适中、特异性较高的检测方法,在新生儿出生后 24 小时至 48 小时内进行更有效;在有重测方案的情况下,在首次测量后两小时内进行更有效。但对早产新生儿的效果并不理想。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Pulse oximetry test for screening congenital heart diseases: a systematic review.

Objective: To determine the accuracy of the Pulse Oximetry Test (POT) in screening for Congenital Heart Diseases (CHD) in newborns in the first 48 hours of life.

Method: Systematic review of diagnostic test accuracy with meta-analysis. The selection of studies was carried out in June 2021. Studies were selected with newborns, in a hospital or home environment, without a previous diagnosis of CHD, regardless of gestational age at birth, who underwent POT within the first 48 hours after birth. Registration on the PROSPERO platform - CRD42021256286.

Results: Twenty-nine studies were included, totaling a population of 388,491 newborns. POT demonstrated sensitivity of 47% (95% CI: 43% to 50%) and specificity of 98% (95% CI: 98% to 98%). Subgroup analyses were carried out according to the different testing period, inclusion of retests in protocols and population of premature newborns.

Conclusion: POT is a test with moderate sensitivity and high specificity. It is more effective when carried out within 24h - 48h of birth; in protocols that present retests, within two hours after the first measurement. It does not show satisfactory effectiveness for premature newborns.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Nursing care for adult patients with chest drainage: a scoping review. ERRATUM: Assessment of workload in the postoperative period of cardiac surgery according to the Nursing Activities Score. ERRATUM: Nursing workload: is it a predictor of healthcare associated infection in intensive care unit? ERRATUM: Prevalence and characteristics of lesions in elderly people living in the community. Mobile application: digital health card for deaf adolescents.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1