正常衰老与早期和中期老年性黄斑变性的杆介导暗适应测试的重复性。

IF 1.7 4区 医学 Q3 OPHTHALMOLOGY Current Eye Research Pub Date : 2024-07-01 Epub Date: 2024-03-04 DOI:10.1080/02713683.2024.2326077
Cynthia Owsley, Thomas A Swain, Gerald McGwin, Mary Margaret Bernard, Mark E Clark, Christine A Curcio
{"title":"正常衰老与早期和中期老年性黄斑变性的杆介导暗适应测试的重复性。","authors":"Cynthia Owsley, Thomas A Swain, Gerald McGwin, Mary Margaret Bernard, Mark E Clark, Christine A Curcio","doi":"10.1080/02713683.2024.2326077","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The vulnerability of rod photoreceptors in aging and early and intermediate age-related macular degeneration (AMD) has been well documented. Rod-mediated dark adaptation (RMDA) is a measure of the recovery of light sensitivity in rod photoreceptors following a bright light. Delays in RMDA during early and intermediate AMD have been widely reported. For RMDA's promise as an outcome for trials targeted at early and intermediate AMD to be realized, excellent test-retest reliability, its repeatability, must be established.</p><p><strong>Methods: </strong>Test-retest performance in a commonly used RMDA test based on the rod intercept time metric (RIT) was evaluated in participants with early and intermediate AMD and with normal retinal aging with testing approximately 2 weeks apart. The test target was placed at 5° eccentricity superior to the foveal center, an area with maximal rod loss in aging and AMD. Disease severity was identified by a trained and masked grader of fundus photographs using both the AREDS 9-step and Beckman classification systems. Bland-Altman plots and intra-class correlation coefficients (ICC) evaluated repeatability.</p><p><strong>Results: </strong>The analysis sample consisted of 37 older adults (mean age 76 years, standard deviation 5), with approximately one-third of the sample in each of three groups - normal aging, early AMD, and intermediate AMD. For the total sample, the ICC was 0.98. For individual AMD groups for both AREDS 9-step and Beckman classifications, the ICCs were also very high ranging from 0.82 to 0.99.</p><p><strong>Conclusion: </strong>We demonstrated that RMDA testing using the RIT metric has excellent repeatability when target location is at 5° in studying older adults from normal aging to intermediate AMD, suggesting the reliable use of this functional measure in trials.</p>","PeriodicalId":10782,"journal":{"name":"Current Eye Research","volume":" ","pages":"725-730"},"PeriodicalIF":1.7000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11199118/pdf/","citationCount":"0","resultStr":"{\"title\":\"Repeatability of Rod-Mediated Dark Adaptation Testing in Normal Aging and Early and Intermediate Age-Related Macular Degeneration.\",\"authors\":\"Cynthia Owsley, Thomas A Swain, Gerald McGwin, Mary Margaret Bernard, Mark E Clark, Christine A Curcio\",\"doi\":\"10.1080/02713683.2024.2326077\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The vulnerability of rod photoreceptors in aging and early and intermediate age-related macular degeneration (AMD) has been well documented. Rod-mediated dark adaptation (RMDA) is a measure of the recovery of light sensitivity in rod photoreceptors following a bright light. Delays in RMDA during early and intermediate AMD have been widely reported. For RMDA's promise as an outcome for trials targeted at early and intermediate AMD to be realized, excellent test-retest reliability, its repeatability, must be established.</p><p><strong>Methods: </strong>Test-retest performance in a commonly used RMDA test based on the rod intercept time metric (RIT) was evaluated in participants with early and intermediate AMD and with normal retinal aging with testing approximately 2 weeks apart. The test target was placed at 5° eccentricity superior to the foveal center, an area with maximal rod loss in aging and AMD. Disease severity was identified by a trained and masked grader of fundus photographs using both the AREDS 9-step and Beckman classification systems. Bland-Altman plots and intra-class correlation coefficients (ICC) evaluated repeatability.</p><p><strong>Results: </strong>The analysis sample consisted of 37 older adults (mean age 76 years, standard deviation 5), with approximately one-third of the sample in each of three groups - normal aging, early AMD, and intermediate AMD. For the total sample, the ICC was 0.98. For individual AMD groups for both AREDS 9-step and Beckman classifications, the ICCs were also very high ranging from 0.82 to 0.99.</p><p><strong>Conclusion: </strong>We demonstrated that RMDA testing using the RIT metric has excellent repeatability when target location is at 5° in studying older adults from normal aging to intermediate AMD, suggesting the reliable use of this functional measure in trials.</p>\",\"PeriodicalId\":10782,\"journal\":{\"name\":\"Current Eye Research\",\"volume\":\" \",\"pages\":\"725-730\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11199118/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Eye Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/02713683.2024.2326077\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/4 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Eye Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/02713683.2024.2326077","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/4 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:杆状光感受器在衰老和早期及中期老年性黄斑变性(AMD)中的脆弱性已得到充分证实。杆介导的暗适应(RMDA)是杆感光器在强光照射后光敏感性恢复的一种测量方法。在早期和中期 AMD 中,RMDA 的延迟已被广泛报道。要使RMDA有望成为针对早期和中期AMD试验的结果,就必须建立良好的重测可靠性,即其可重复性:方法:在早期和中期 AMD 患者以及视网膜正常老化患者中,对基于杆截距时间度量(RIT)的常用 RMDA 测试的重测性能进行了评估,测试间隔时间约为 2 周。测试目标位于眼窝中心偏上 5° 的位置,这是老化和 AMD 患者视杆细胞丧失最多的区域。疾病的严重程度由一名经过培训的蒙面眼底照片分级者使用 AREDS 9 级和贝克曼分类系统进行鉴定。平原-阿尔特曼图和类内相关系数(ICC)评估了重复性:分析样本包括 37 名老年人(平均年龄 76 岁,标准差 5),其中约三分之一的样本分别属于正常衰老、早期 AMD 和中期 AMD 三个组别。总样本的 ICC 为 0.98。对于 AREDS 9 步分类和贝克曼分类的各个 AMD 组,ICC 也非常高,从 0.82 到 0.99 不等:我们证明,在研究从正常衰老到中度 AMD 的老年人时,当目标位置在 5° 时,使用 RIT 指标进行 RMDA 测试具有极佳的可重复性,这表明在试验中使用这种功能测量方法是可靠的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Repeatability of Rod-Mediated Dark Adaptation Testing in Normal Aging and Early and Intermediate Age-Related Macular Degeneration.

Purpose: The vulnerability of rod photoreceptors in aging and early and intermediate age-related macular degeneration (AMD) has been well documented. Rod-mediated dark adaptation (RMDA) is a measure of the recovery of light sensitivity in rod photoreceptors following a bright light. Delays in RMDA during early and intermediate AMD have been widely reported. For RMDA's promise as an outcome for trials targeted at early and intermediate AMD to be realized, excellent test-retest reliability, its repeatability, must be established.

Methods: Test-retest performance in a commonly used RMDA test based on the rod intercept time metric (RIT) was evaluated in participants with early and intermediate AMD and with normal retinal aging with testing approximately 2 weeks apart. The test target was placed at 5° eccentricity superior to the foveal center, an area with maximal rod loss in aging and AMD. Disease severity was identified by a trained and masked grader of fundus photographs using both the AREDS 9-step and Beckman classification systems. Bland-Altman plots and intra-class correlation coefficients (ICC) evaluated repeatability.

Results: The analysis sample consisted of 37 older adults (mean age 76 years, standard deviation 5), with approximately one-third of the sample in each of three groups - normal aging, early AMD, and intermediate AMD. For the total sample, the ICC was 0.98. For individual AMD groups for both AREDS 9-step and Beckman classifications, the ICCs were also very high ranging from 0.82 to 0.99.

Conclusion: We demonstrated that RMDA testing using the RIT metric has excellent repeatability when target location is at 5° in studying older adults from normal aging to intermediate AMD, suggesting the reliable use of this functional measure in trials.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Current Eye Research
Current Eye Research 医学-眼科学
CiteScore
4.60
自引率
0.00%
发文量
163
审稿时长
12 months
期刊介绍: The principal aim of Current Eye Research is to provide rapid publication of full papers, short communications and mini-reviews, all high quality. Current Eye Research publishes articles encompassing all the areas of eye research. Subject areas include the following: clinical research, anatomy, physiology, biophysics, biochemistry, pharmacology, developmental biology, microbiology and immunology.
期刊最新文献
Four-Year Longitudinal Investigation of the Relationship Between Myopia and Retinal Shape in Chinese Children: The Anyang Childhood Eye Study. The Potential Role of Exosomes in Ocular Surface and Lacrimal Gland Regeneration. Visual Acuity and Refractive Status in Congenital Macular Coloboma. Radiological Imaging of the Lacrimal Gland in Sjogren's Syndrome: A Systematic Review and Meta-Analysis. Changes in Posterior Ocular Structures in Individuals Using Phosphodiesterase 5 Inhibitor.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1