R. Macedo-De-Araújo, Laura Rico-del-Viejo, Vicente Martín-Montañéz, A. Queirós, J. González-Méijome
{"title":"新一代日抛型硅水凝胶隐形眼镜日间泪膜参数和视力变化--对有症状受试者的双掩蔽研究","authors":"R. Macedo-De-Araújo, Laura Rico-del-Viejo, Vicente Martín-Montañéz, A. Queirós, J. González-Méijome","doi":"10.3390/vision8010011","DOIUrl":null,"url":null,"abstract":"This prospective, double-masked, contralateral study aimed to analyze and compare daytime changes in pre-lens tear film (PLTF) stability and optical quality in symptomatic subjects wearing two contact lenses (CL). A secondary goal was to assess the performance of the PLTF by using dynamic topography techniques and analyzing surface asymmetry and irregularity indexes (SAI and SRI, respectively). Measurements were conducted on 20 symptomatic subjects (OSDI score > 13). Participants were fitted contralaterally and randomly with spherical Delefilcon A and Stenfilcon A CLs and underwent a series of measurements over 3 consecutive days: three in the morning (after 1–2 h of CL wear) and three in the afternoon (after 7–9 h of CL wear). High- and low-contrast visual acuity (HCVA and LCVA, respectively), pre-lens NIBUT, and dynamic topography were assessed. The contralateral fit of the two lenses allowed a direct and better comparison between them since they were exposed to the same conditions during the day. Consequently, both lenses demonstrated similar performance in HCVA, LCVA, and PLTF stability, with no statistically significant differences between them, although some fluctuations were observed throughout the day. Dynamic topography proved sensitive in evaluating temporal changes in the PLTF. The SRI index showed greater sensitivity to topographic changes due to lacrimal destabilization, making it potentially valuable for evaluating dry eye patients.","PeriodicalId":23649,"journal":{"name":"Vision","volume":"114 21","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Daytime Changes in Tear Film Parameters and Visual Acuity with New-Generation Daily Disposable Silicone Hydrogel Contact Lenses—A Double-Masked Study in Symptomatic Subjects\",\"authors\":\"R. Macedo-De-Araújo, Laura Rico-del-Viejo, Vicente Martín-Montañéz, A. Queirós, J. González-Méijome\",\"doi\":\"10.3390/vision8010011\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This prospective, double-masked, contralateral study aimed to analyze and compare daytime changes in pre-lens tear film (PLTF) stability and optical quality in symptomatic subjects wearing two contact lenses (CL). A secondary goal was to assess the performance of the PLTF by using dynamic topography techniques and analyzing surface asymmetry and irregularity indexes (SAI and SRI, respectively). Measurements were conducted on 20 symptomatic subjects (OSDI score > 13). Participants were fitted contralaterally and randomly with spherical Delefilcon A and Stenfilcon A CLs and underwent a series of measurements over 3 consecutive days: three in the morning (after 1–2 h of CL wear) and three in the afternoon (after 7–9 h of CL wear). High- and low-contrast visual acuity (HCVA and LCVA, respectively), pre-lens NIBUT, and dynamic topography were assessed. The contralateral fit of the two lenses allowed a direct and better comparison between them since they were exposed to the same conditions during the day. Consequently, both lenses demonstrated similar performance in HCVA, LCVA, and PLTF stability, with no statistically significant differences between them, although some fluctuations were observed throughout the day. Dynamic topography proved sensitive in evaluating temporal changes in the PLTF. The SRI index showed greater sensitivity to topographic changes due to lacrimal destabilization, making it potentially valuable for evaluating dry eye patients.\",\"PeriodicalId\":23649,\"journal\":{\"name\":\"Vision\",\"volume\":\"114 21\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Vision\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/vision8010011\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vision","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/vision8010011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Daytime Changes in Tear Film Parameters and Visual Acuity with New-Generation Daily Disposable Silicone Hydrogel Contact Lenses—A Double-Masked Study in Symptomatic Subjects
This prospective, double-masked, contralateral study aimed to analyze and compare daytime changes in pre-lens tear film (PLTF) stability and optical quality in symptomatic subjects wearing two contact lenses (CL). A secondary goal was to assess the performance of the PLTF by using dynamic topography techniques and analyzing surface asymmetry and irregularity indexes (SAI and SRI, respectively). Measurements were conducted on 20 symptomatic subjects (OSDI score > 13). Participants were fitted contralaterally and randomly with spherical Delefilcon A and Stenfilcon A CLs and underwent a series of measurements over 3 consecutive days: three in the morning (after 1–2 h of CL wear) and three in the afternoon (after 7–9 h of CL wear). High- and low-contrast visual acuity (HCVA and LCVA, respectively), pre-lens NIBUT, and dynamic topography were assessed. The contralateral fit of the two lenses allowed a direct and better comparison between them since they were exposed to the same conditions during the day. Consequently, both lenses demonstrated similar performance in HCVA, LCVA, and PLTF stability, with no statistically significant differences between them, although some fluctuations were observed throughout the day. Dynamic topography proved sensitive in evaluating temporal changes in the PLTF. The SRI index showed greater sensitivity to topographic changes due to lacrimal destabilization, making it potentially valuable for evaluating dry eye patients.