使用新型刀片式设备进行原生主动脉瓣切除术

Emiliano Navarra, Xavier Bollen, Francesco Zito, Laurent de Kerchove, Gebrine El Khoury, Astarci Parla
{"title":"使用新型刀片式设备进行原生主动脉瓣切除术","authors":"Emiliano Navarra, Xavier Bollen, Francesco Zito, Laurent de Kerchove, Gebrine El Khoury, Astarci Parla","doi":"10.1177/15569845241232645","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The aim of this study was to validate the use of a new resection device in patient candidates for surgical aortic valve replacement. We evaluated the efficacy of this new circular blade to resect the aortic valve and the efficacy to collect the debris during the resection.</p><p><strong>Methods: </strong>For this study, a single size instrument was used, with an external diameter of 22 mm, and patients were selected on the basis of the preoperative assessment of the aortic diameters.</p><p><strong>Results: </strong>From October 2018 to June 2019, 10 patient candidates for surgical aortic valve replacement were selected to undergo native aortic valve resection using a new device, before surgical valve implantation. The mean age of the patients was 74 ± 7.6 years, and 8 of 10 were male. The mean aortic annulus diameter, measured before the procedure, was 25.7 ± 1.57 mm. The resection was complete in 9 (90%) patients. In 1 patient, due to an imprecise positioning of the device, the valve resection was partial. None of the patients showed signs or symptoms due to debris embolism. In all patients, the postoperative course was uneventful.</p><p><strong>Conclusions: </strong>These preliminary results show that resection of the aortic valve using a circular foldable blade is feasible. This prototype, used during conventional surgery even through a small incision, provided an efficient tool to easily resect the valve without debris release.</p>","PeriodicalId":13574,"journal":{"name":"Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery","volume":" ","pages":"150-155"},"PeriodicalIF":1.6000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Native Aortic Valve Resection Using a Novel Blade-Based Device.\",\"authors\":\"Emiliano Navarra, Xavier Bollen, Francesco Zito, Laurent de Kerchove, Gebrine El Khoury, Astarci Parla\",\"doi\":\"10.1177/15569845241232645\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>The aim of this study was to validate the use of a new resection device in patient candidates for surgical aortic valve replacement. We evaluated the efficacy of this new circular blade to resect the aortic valve and the efficacy to collect the debris during the resection.</p><p><strong>Methods: </strong>For this study, a single size instrument was used, with an external diameter of 22 mm, and patients were selected on the basis of the preoperative assessment of the aortic diameters.</p><p><strong>Results: </strong>From October 2018 to June 2019, 10 patient candidates for surgical aortic valve replacement were selected to undergo native aortic valve resection using a new device, before surgical valve implantation. The mean age of the patients was 74 ± 7.6 years, and 8 of 10 were male. The mean aortic annulus diameter, measured before the procedure, was 25.7 ± 1.57 mm. The resection was complete in 9 (90%) patients. In 1 patient, due to an imprecise positioning of the device, the valve resection was partial. None of the patients showed signs or symptoms due to debris embolism. In all patients, the postoperative course was uneventful.</p><p><strong>Conclusions: </strong>These preliminary results show that resection of the aortic valve using a circular foldable blade is feasible. This prototype, used during conventional surgery even through a small incision, provided an efficient tool to easily resect the valve without debris release.</p>\",\"PeriodicalId\":13574,\"journal\":{\"name\":\"Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery\",\"volume\":\" \",\"pages\":\"150-155\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/15569845241232645\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/10 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/15569845241232645","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/10 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究旨在验证一种新型切除装置在主动脉瓣置换术候选患者中的应用。我们评估了这种新型圆形刀片切除主动脉瓣的效果以及在切除过程中收集碎片的效果:在这项研究中,我们使用了一种外径为 22 毫米的单一规格器械,并根据术前对主动脉直径的评估来选择患者:2018年10月至2019年6月,选择了10名手术主动脉瓣置换术的候选患者,在手术瓣膜植入前使用新器械进行原位主动脉瓣切除术。患者的平均年龄为 74 ± 7.6 岁,10 人中有 8 名男性。术前测量的平均主动脉瓣环直径为 25.7 ± 1.57 毫米。9名患者(90%)完成了切除。1名患者由于装置定位不精确,瓣膜切除为部分切除。没有一名患者出现碎片栓塞的体征或症状。所有患者的术后过程都很顺利:这些初步结果表明,使用圆形可折叠刀片切除主动脉瓣是可行的。这种原型在传统手术中即使通过小切口也能使用,为轻松切除瓣膜而不释放碎片提供了有效工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Native Aortic Valve Resection Using a Novel Blade-Based Device.

Objective: The aim of this study was to validate the use of a new resection device in patient candidates for surgical aortic valve replacement. We evaluated the efficacy of this new circular blade to resect the aortic valve and the efficacy to collect the debris during the resection.

Methods: For this study, a single size instrument was used, with an external diameter of 22 mm, and patients were selected on the basis of the preoperative assessment of the aortic diameters.

Results: From October 2018 to June 2019, 10 patient candidates for surgical aortic valve replacement were selected to undergo native aortic valve resection using a new device, before surgical valve implantation. The mean age of the patients was 74 ± 7.6 years, and 8 of 10 were male. The mean aortic annulus diameter, measured before the procedure, was 25.7 ± 1.57 mm. The resection was complete in 9 (90%) patients. In 1 patient, due to an imprecise positioning of the device, the valve resection was partial. None of the patients showed signs or symptoms due to debris embolism. In all patients, the postoperative course was uneventful.

Conclusions: These preliminary results show that resection of the aortic valve using a circular foldable blade is feasible. This prototype, used during conventional surgery even through a small incision, provided an efficient tool to easily resect the valve without debris release.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.00
自引率
6.70%
发文量
80
期刊介绍: Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery is the first journal whose main mission is to disseminate information specifically about advances in technology and techniques that lead to less invasive treatment of cardiothoracic and vascular disease. It delivers cutting edge original research, reviews, essays, case reports, and editorials from the pioneers and experts in the field of minimally invasive cardiothoracic and vascular disease, including biomedical engineers. Also included are papers presented at the annual ISMICS meeting. Official Journal of the International Society for Minimally Invasive Cardiothoracic Surgery
期刊最新文献
Totally Endoscopic Coronary Artery Bypass Graft: Systematic Review and Meta-Analysis of Reconstructed Patient-Level Data. The 10 Commandments for State-of-the-Art Imaging of the Proximal Thoracic Aorta. Robot-Assisted Atrial Septal Defect Closure Via the Left Atrium: Dual Case Reports. The 10 Commandments of Endo-Bentall Repair. Innovative Surgical Left Atrial Appendage Closure Technique: Early Experience of Inverted Spiral Closure Technique.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1