{"title":"数字图像比色法测定河流沉积物中铁含量的可行性","authors":"","doi":"10.1016/j.ijsrc.2024.02.005","DOIUrl":null,"url":null,"abstract":"<div><p>The current study describes the development of simple, low-cost, and high-throughput digital image colorimetric methods to determine the total iron concentration in river sediment using the spot-test reactions of iron with 1,10-phenanthroline and thiocyanate. The colorimetric assay was done on 96-microzone plates, and a flatbed scanner was applied to acquire the images. The proposed methods offered a linear range from 0.2 to 14.0 mg/L, with a detection limit of 0.11 mg/kg for the 1,10-phenanthroline method, and, for the thiocyanate method, the linear range comprises 2.0–10.0 mg/L, with a detection limit of 0.28 mg/kg. It was observed that both proposed digital image colorimetric methods (1,10-phenanthroline and thiocyanate) yielded statistically similar results to the reference procedures at a 95% confidence level. A standard reference material (NIST 8704) also was utilized for accuracy assessment and the results were statistically equivalent to the certified values within the 95% confidence level. The digital image colorimetric methods can be an alternative method for iron determination in sediment samples, allowing fast sample screening at a low cost.</p></div>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1001627924000180/pdfft?md5=992fdc80aba029805a484f8197083a45&pid=1-s2.0-S1001627924000180-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Feasibility of digital image colorimetric methods for iron determination in river sediment\",\"authors\":\"\",\"doi\":\"10.1016/j.ijsrc.2024.02.005\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The current study describes the development of simple, low-cost, and high-throughput digital image colorimetric methods to determine the total iron concentration in river sediment using the spot-test reactions of iron with 1,10-phenanthroline and thiocyanate. The colorimetric assay was done on 96-microzone plates, and a flatbed scanner was applied to acquire the images. The proposed methods offered a linear range from 0.2 to 14.0 mg/L, with a detection limit of 0.11 mg/kg for the 1,10-phenanthroline method, and, for the thiocyanate method, the linear range comprises 2.0–10.0 mg/L, with a detection limit of 0.28 mg/kg. It was observed that both proposed digital image colorimetric methods (1,10-phenanthroline and thiocyanate) yielded statistically similar results to the reference procedures at a 95% confidence level. A standard reference material (NIST 8704) also was utilized for accuracy assessment and the results were statistically equivalent to the certified values within the 95% confidence level. The digital image colorimetric methods can be an alternative method for iron determination in sediment samples, allowing fast sample screening at a low cost.</p></div>\",\"PeriodicalId\":3,\"journal\":{\"name\":\"ACS Applied Electronic Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2024-03-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S1001627924000180/pdfft?md5=992fdc80aba029805a484f8197083a45&pid=1-s2.0-S1001627924000180-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Electronic Materials\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1001627924000180\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"93","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1001627924000180","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Feasibility of digital image colorimetric methods for iron determination in river sediment
The current study describes the development of simple, low-cost, and high-throughput digital image colorimetric methods to determine the total iron concentration in river sediment using the spot-test reactions of iron with 1,10-phenanthroline and thiocyanate. The colorimetric assay was done on 96-microzone plates, and a flatbed scanner was applied to acquire the images. The proposed methods offered a linear range from 0.2 to 14.0 mg/L, with a detection limit of 0.11 mg/kg for the 1,10-phenanthroline method, and, for the thiocyanate method, the linear range comprises 2.0–10.0 mg/L, with a detection limit of 0.28 mg/kg. It was observed that both proposed digital image colorimetric methods (1,10-phenanthroline and thiocyanate) yielded statistically similar results to the reference procedures at a 95% confidence level. A standard reference material (NIST 8704) also was utilized for accuracy assessment and the results were statistically equivalent to the certified values within the 95% confidence level. The digital image colorimetric methods can be an alternative method for iron determination in sediment samples, allowing fast sample screening at a low cost.