Kazuo Ouchi, Mari Sato, Yuki Kashiwabara, Mutsumi Shimazaki, Shoji Yabuki
{"title":"髋关节截肢后行走速度和足底压力的调查。","authors":"Kazuo Ouchi, Mari Sato, Yuki Kashiwabara, Mutsumi Shimazaki, Shoji Yabuki","doi":"10.5387/fms.23-00003","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>In foot amputation, Chopart amputation is considered to have a high risk of deformity, and can result in poor function. We experienced a case in which Chopart amputation combined with tendon transfer and tendon lengthening was performed, and the patient was eventually able to walk independently with a foot prosthesis without experiencing deformity of the foot. We investigated walking speed and plantar pressure after Chopart amputation with and without a foot prosthesis.</p><p><strong>Case: </strong>A 78-year-old man underwent Chopart amputation with tendon transfer and tendon lengthening. As a result, he was able to stand up and walk, both while bearing weight on the heel of the affected foot, but he was unable to push off the ground using that foot. When a foot prosthesis was introduced, the patient's walking speed increased from 0.6 m/s without the prosthesis to 0.8 m/s with the prosthesis, which was an increase of 33%. The plantar pressure at the stump decreased from 129.3 N/cm<sup>2</sup> on average without the prosthesis to 51.6 N/cm<sup>2</sup> with the prosthesis, which was a 59% decrease. Wearing a foot prosthesis improved the patient's walking speed and decreased plantar pressure at the amputation stump.</p>","PeriodicalId":44831,"journal":{"name":"Fukushima Journal of Medical Science","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2024-04-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11140196/pdf/","citationCount":"0","resultStr":"{\"title\":\"Investigation of walking speed and plantar pressure after chopart amputation.\",\"authors\":\"Kazuo Ouchi, Mari Sato, Yuki Kashiwabara, Mutsumi Shimazaki, Shoji Yabuki\",\"doi\":\"10.5387/fms.23-00003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>In foot amputation, Chopart amputation is considered to have a high risk of deformity, and can result in poor function. We experienced a case in which Chopart amputation combined with tendon transfer and tendon lengthening was performed, and the patient was eventually able to walk independently with a foot prosthesis without experiencing deformity of the foot. We investigated walking speed and plantar pressure after Chopart amputation with and without a foot prosthesis.</p><p><strong>Case: </strong>A 78-year-old man underwent Chopart amputation with tendon transfer and tendon lengthening. As a result, he was able to stand up and walk, both while bearing weight on the heel of the affected foot, but he was unable to push off the ground using that foot. When a foot prosthesis was introduced, the patient's walking speed increased from 0.6 m/s without the prosthesis to 0.8 m/s with the prosthesis, which was an increase of 33%. The plantar pressure at the stump decreased from 129.3 N/cm<sup>2</sup> on average without the prosthesis to 51.6 N/cm<sup>2</sup> with the prosthesis, which was a 59% decrease. Wearing a foot prosthesis improved the patient's walking speed and decreased plantar pressure at the amputation stump.</p>\",\"PeriodicalId\":44831,\"journal\":{\"name\":\"Fukushima Journal of Medical Science\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2024-04-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11140196/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fukushima Journal of Medical Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5387/fms.23-00003\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/15 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fukushima Journal of Medical Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5387/fms.23-00003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/15 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

摘要

背景:在足部截肢中,Chopart截肢被认为具有较高的畸形风险,并可能导致功能低下。我们经历了一例 Chopart 截肢术联合肌腱转移和肌腱延长术的病例,患者最终能够使用足部假肢独立行走,足部没有出现畸形。我们研究了乔巴特截肢术后使用和不使用足部假肢时的行走速度和足底压力:一名 78 岁的男性接受了 Chopart 截肢术,同时进行了肌腱转移和肌腱延长术。结果,他能够站立和行走,同时用患足的足跟负重,但无法用该足推离地面。安装假肢后,患者的行走速度从未装假肢时的 0.6 米/秒提高到装上假肢后的 0.8 米/秒,提高了 33%。残肢处的足底压力从未装假肢时的平均 129.3 牛/平方厘米降至装上假肢后的 51.6 牛/平方厘米,降幅达 59%。佩戴义足提高了患者的行走速度,降低了截肢残端处的足底压力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Investigation of walking speed and plantar pressure after chopart amputation.

Background: In foot amputation, Chopart amputation is considered to have a high risk of deformity, and can result in poor function. We experienced a case in which Chopart amputation combined with tendon transfer and tendon lengthening was performed, and the patient was eventually able to walk independently with a foot prosthesis without experiencing deformity of the foot. We investigated walking speed and plantar pressure after Chopart amputation with and without a foot prosthesis.

Case: A 78-year-old man underwent Chopart amputation with tendon transfer and tendon lengthening. As a result, he was able to stand up and walk, both while bearing weight on the heel of the affected foot, but he was unable to push off the ground using that foot. When a foot prosthesis was introduced, the patient's walking speed increased from 0.6 m/s without the prosthesis to 0.8 m/s with the prosthesis, which was an increase of 33%. The plantar pressure at the stump decreased from 129.3 N/cm2 on average without the prosthesis to 51.6 N/cm2 with the prosthesis, which was a 59% decrease. Wearing a foot prosthesis improved the patient's walking speed and decreased plantar pressure at the amputation stump.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Fukushima Journal of Medical Science
Fukushima Journal of Medical Science MEDICINE, GENERAL & INTERNAL-
CiteScore
1.70
自引率
12.50%
发文量
24
期刊最新文献
Comparison of attitudes toward schizophrenia among medical students and health professionals in Japan and their associated factorsamong medical students: a cross-sectional study. Histological outcome evaluation of selected brain preparation protocols for white fiber dissection. Remote Orthotic Fabrication Method Using Small Three-Dimensional Printers and Computed Tomography Data: A Technical Report. Seven cases illustrating difficulties in the treatment of MPO-ANCA-positive refractory otitis media. Subjective Difficulty with Higher-Level Functional Capacity in Community-Dwelling Older People withMild Cognitive Impairment.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1