研究各种粘合剂系统在支架安置中的粘合强度

Hayan Almokaddam, N. Tuturov, I. Katbeh
{"title":"研究各种粘合剂系统在支架安置中的粘合强度","authors":"Hayan Almokaddam, N. Tuturov, I. Katbeh","doi":"10.22363/2313-0245-2024-28-1-35-45","DOIUrl":null,"url":null,"abstract":"Relevance . Today, the dental market offers a large selection of adhesive systems developed based on various concepts. Improving adhesive technology in orthodontic practice is aimed at simplifying methods of use, improving the composition and ability of adhesion of orthodontic elements to the tooth structure. The aim of this study is to compare the shear bonding strength of different generations of adhesive systems for metal brackets placement. Materials and Methods . The study sample consisted of 40 recently extracted human upper premolars. The premolars were divided into four groups 10 each. The first group used the bond Transbond XT 3M Unitek (USA), the second - Beauty Ortho Bond (Japan), the third - Tetric N bond Universal (Vivapen) (USA) with acid etching with phosphoric acid (LI), the fourth - Tetric N bond Universal (Vivapen) (USA) without acid etching with phosphoric acid. The study used metal brackets for upper premolars (Gemini Bracket MBT, 3M Unitek, USA) with a micro-patterned base, the area of which was defined as 10.61 mm2. Mechanical shear strength tests were carried out using the Instron Universal Test machine (USA). One-way analysis of variance and the TUKEY test were used to examine significant differences in adhesive strength and shear strength between study groups. Results and Discussion. The highest adhesive shear strength was established when using the Transbond XT adhesive system (12.28 MPa) and the Tetric N Bond Universal system using the total etching (12.66 MPa) and self-etching (11.44 MPa) techniques; statistically significant differences between these adhesives were not detected. The second group of Beauty Ortho Bond (5.34 MPa) demonstrated the lowest adhesion force among the studied adhesives, with a statistically significant difference from the other groups. Conclusion : This study concluded that there are no notable differences in the comparison of the universal system with or without etching with the Transbond system. Regarding the use of the beauty Ortho bond, it obtained the lowest strength with significant difference from the remaining groups.","PeriodicalId":21324,"journal":{"name":"RUDN Journal of Medicine","volume":"85 9","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Study of various adhesive systems’ bond strength for bracket placement\",\"authors\":\"Hayan Almokaddam, N. Tuturov, I. Katbeh\",\"doi\":\"10.22363/2313-0245-2024-28-1-35-45\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Relevance . Today, the dental market offers a large selection of adhesive systems developed based on various concepts. Improving adhesive technology in orthodontic practice is aimed at simplifying methods of use, improving the composition and ability of adhesion of orthodontic elements to the tooth structure. The aim of this study is to compare the shear bonding strength of different generations of adhesive systems for metal brackets placement. Materials and Methods . The study sample consisted of 40 recently extracted human upper premolars. The premolars were divided into four groups 10 each. The first group used the bond Transbond XT 3M Unitek (USA), the second - Beauty Ortho Bond (Japan), the third - Tetric N bond Universal (Vivapen) (USA) with acid etching with phosphoric acid (LI), the fourth - Tetric N bond Universal (Vivapen) (USA) without acid etching with phosphoric acid. The study used metal brackets for upper premolars (Gemini Bracket MBT, 3M Unitek, USA) with a micro-patterned base, the area of which was defined as 10.61 mm2. Mechanical shear strength tests were carried out using the Instron Universal Test machine (USA). One-way analysis of variance and the TUKEY test were used to examine significant differences in adhesive strength and shear strength between study groups. Results and Discussion. The highest adhesive shear strength was established when using the Transbond XT adhesive system (12.28 MPa) and the Tetric N Bond Universal system using the total etching (12.66 MPa) and self-etching (11.44 MPa) techniques; statistically significant differences between these adhesives were not detected. The second group of Beauty Ortho Bond (5.34 MPa) demonstrated the lowest adhesion force among the studied adhesives, with a statistically significant difference from the other groups. Conclusion : This study concluded that there are no notable differences in the comparison of the universal system with or without etching with the Transbond system. Regarding the use of the beauty Ortho bond, it obtained the lowest strength with significant difference from the remaining groups.\",\"PeriodicalId\":21324,\"journal\":{\"name\":\"RUDN Journal of Medicine\",\"volume\":\"85 9\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"RUDN Journal of Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22363/2313-0245-2024-28-1-35-45\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"RUDN Journal of Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22363/2313-0245-2024-28-1-35-45","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

相关性 .如今,牙科市场上有大量基于各种概念开发的粘合剂系统可供选择。在正畸实践中改进粘合剂技术的目的是简化使用方法,改善正畸元件的成分和与牙齿结构的粘合能力。本研究的目的是比较用于金属托槽安装的不同代粘合剂系统的剪切粘接强度。材料和方法研究样本包括 40 颗最近拔出的人类上前磨牙。这些前臼齿被分为四组,每组 10 颗。第一组使用的粘接剂是 Transbond XT 3M Unitek(美国),第二组使用的是 Beauty Ortho Bond(日本),第三组使用的是 Tetric N bond Universal (Vivapen)(美国),并用磷酸进行了酸蚀处理(LI),第四组使用的是 Tetric N bond Universal (Vivapen)(美国),未用磷酸进行酸蚀处理。研究使用的是上前磨牙金属托架(Gemini Bracket MBT,3M Unitek,美国),带有微图案底座,面积定义为 10.61 平方毫米。使用美国 Instron 万能试验机进行了机械剪切强度测试。采用单因素方差分析和 TUKEY 检验来检查研究组之间粘接强度和剪切强度的显著差异。结果与讨论。使用 Transbond XT 粘接系统(12.28 兆帕)和使用全蚀刻(12.66 兆帕)和自蚀刻(11.44 兆帕)技术的 Tetric N Bond Universal 系统时,粘接剪切强度最高;这些粘接剂之间未发现明显的统计学差异。在所研究的粘合剂中,第二组 Beauty Ortho Bond(5.34 兆帕)的粘合力最低,与其他组的差异在统计学上有显著性。结论:本研究得出结论,有无蚀刻的通用系统与 Transbond 系统相比没有明显差异。在使用美容 Ortho 粘合剂方面,其粘合力最低,与其他组别相比差异显著。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Study of various adhesive systems’ bond strength for bracket placement
Relevance . Today, the dental market offers a large selection of adhesive systems developed based on various concepts. Improving adhesive technology in orthodontic practice is aimed at simplifying methods of use, improving the composition and ability of adhesion of orthodontic elements to the tooth structure. The aim of this study is to compare the shear bonding strength of different generations of adhesive systems for metal brackets placement. Materials and Methods . The study sample consisted of 40 recently extracted human upper premolars. The premolars were divided into four groups 10 each. The first group used the bond Transbond XT 3M Unitek (USA), the second - Beauty Ortho Bond (Japan), the third - Tetric N bond Universal (Vivapen) (USA) with acid etching with phosphoric acid (LI), the fourth - Tetric N bond Universal (Vivapen) (USA) without acid etching with phosphoric acid. The study used metal brackets for upper premolars (Gemini Bracket MBT, 3M Unitek, USA) with a micro-patterned base, the area of which was defined as 10.61 mm2. Mechanical shear strength tests were carried out using the Instron Universal Test machine (USA). One-way analysis of variance and the TUKEY test were used to examine significant differences in adhesive strength and shear strength between study groups. Results and Discussion. The highest adhesive shear strength was established when using the Transbond XT adhesive system (12.28 MPa) and the Tetric N Bond Universal system using the total etching (12.66 MPa) and self-etching (11.44 MPa) techniques; statistically significant differences between these adhesives were not detected. The second group of Beauty Ortho Bond (5.34 MPa) demonstrated the lowest adhesion force among the studied adhesives, with a statistically significant difference from the other groups. Conclusion : This study concluded that there are no notable differences in the comparison of the universal system with or without etching with the Transbond system. Regarding the use of the beauty Ortho bond, it obtained the lowest strength with significant difference from the remaining groups.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.50
自引率
0.00%
发文量
43
审稿时长
8 weeks
期刊最新文献
Role of child behavior management in forming positive associations with the dentist Spleen white pulp structural and cellular composition in experimental furosemide-­induced hypomagnesemia Study of various adhesive systems’ bond strength for bracket placement Techniques for conservative treatment of peri-implantitis Combination of neuromuscular block monitoring and hand grip strength assessment for patients undergoing emergency abdominal surgery
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1