利用 1H NMR 光谱和 PULCON 方法全自动定量咖啡中的八种不同代谢物

IF 1.1 JSFA reports Pub Date : 2024-03-10 DOI:10.1002/jsf2.184
Vera Gottstein, Dirk W. Lachenmeier, Thomas Kuballa, Mirko Bunzel
{"title":"利用 1H NMR 光谱和 PULCON 方法全自动定量咖啡中的八种不同代谢物","authors":"Vera Gottstein,&nbsp;Dirk W. Lachenmeier,&nbsp;Thomas Kuballa,&nbsp;Mirko Bunzel","doi":"10.1002/jsf2.184","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>Coffee contains a plethora of constituents with some of them being especially important either due to their physiological effects or as quality markers. As quantitative proton nuclear magnetic resonance spectroscopy (<sup>1</sup>H-NMR) has been established as a fast and reliable analytical tool its application was evaluated for the simultaneous quantitation of lactic acid, acetic acid, formic acid, caffeine, caffeoylquinic acid (CQA) isomers, <i>N</i>-methylpyridinium, trigonelline, and 5-hydroxymethylfurfural (HMF) in aqueous extracts of roasted <i>Coffea arabica</i> samples.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Simultaneous quantitative determination was achieved by an automated analysis based on the PULCON methodology (pulse length-based concentration determination). The method was validated regarding linearity, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ). Recovery rates were between 76% (CQA) and 116% (HMF), and precision was between 1.7% (caffeine) and 10.3% (HMF). The LOD varied between 0.06 g/kg (HMF) and 1.35 g/kg (caffeine and CQA), with the LOQ being between 0.22 g/kg (HMF) and 4.87 g/kg (CQA). To verify the results of the <sup>1</sup>H-NMR method, caffeine, trigonelline, HMF, 3-CQA, 4-CQA, and 5-CQA were additionally quantitated by HPLC-DAD and the results were compared. The described <sup>1</sup>H-NMR method was additionally applied to coffee samples that contained different coffee defects. Results showed only slight changes in the concentrations of the analytes by adding defective beans to defect-free coffee.</p>\n </section>\n \n <section>\n \n <h3> Discussion</h3>\n \n <p>The developed 1H-NMR approach was proven to be fast (30 min), reliable, and precise. Thus, it is well suited to analyze several coffee constituents of interest in a large number of samples in, for example, quality control.</p>\n </section>\n </div>","PeriodicalId":93795,"journal":{"name":"JSFA reports","volume":"4 3","pages":"163-174"},"PeriodicalIF":1.1000,"publicationDate":"2024-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/jsf2.184","citationCount":"0","resultStr":"{\"title\":\"Fully automatic quantitation of eight different metabolites in coffee using 1H-NMR spectroscopy and the PULCON methodology\",\"authors\":\"Vera Gottstein,&nbsp;Dirk W. Lachenmeier,&nbsp;Thomas Kuballa,&nbsp;Mirko Bunzel\",\"doi\":\"10.1002/jsf2.184\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Background</h3>\\n \\n <p>Coffee contains a plethora of constituents with some of them being especially important either due to their physiological effects or as quality markers. As quantitative proton nuclear magnetic resonance spectroscopy (<sup>1</sup>H-NMR) has been established as a fast and reliable analytical tool its application was evaluated for the simultaneous quantitation of lactic acid, acetic acid, formic acid, caffeine, caffeoylquinic acid (CQA) isomers, <i>N</i>-methylpyridinium, trigonelline, and 5-hydroxymethylfurfural (HMF) in aqueous extracts of roasted <i>Coffea arabica</i> samples.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>Simultaneous quantitative determination was achieved by an automated analysis based on the PULCON methodology (pulse length-based concentration determination). The method was validated regarding linearity, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ). Recovery rates were between 76% (CQA) and 116% (HMF), and precision was between 1.7% (caffeine) and 10.3% (HMF). The LOD varied between 0.06 g/kg (HMF) and 1.35 g/kg (caffeine and CQA), with the LOQ being between 0.22 g/kg (HMF) and 4.87 g/kg (CQA). To verify the results of the <sup>1</sup>H-NMR method, caffeine, trigonelline, HMF, 3-CQA, 4-CQA, and 5-CQA were additionally quantitated by HPLC-DAD and the results were compared. The described <sup>1</sup>H-NMR method was additionally applied to coffee samples that contained different coffee defects. Results showed only slight changes in the concentrations of the analytes by adding defective beans to defect-free coffee.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Discussion</h3>\\n \\n <p>The developed 1H-NMR approach was proven to be fast (30 min), reliable, and precise. Thus, it is well suited to analyze several coffee constituents of interest in a large number of samples in, for example, quality control.</p>\\n </section>\\n </div>\",\"PeriodicalId\":93795,\"journal\":{\"name\":\"JSFA reports\",\"volume\":\"4 3\",\"pages\":\"163-174\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-03-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/jsf2.184\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JSFA reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://scijournals.onlinelibrary.wiley.com/doi/10.1002/jsf2.184\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JSFA reports","FirstCategoryId":"1085","ListUrlMain":"https://scijournals.onlinelibrary.wiley.com/doi/10.1002/jsf2.184","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

咖啡中含有大量成分,其中一些成分因其生理作用或作为质量标记而显得尤为重要。由于定量质子核磁共振光谱(1H-NMR)是一种快速可靠的分析工具,因此我们对其在同时定量测定烘焙阿拉伯咖啡豆水提取物中的乳酸、乙酸、甲酸、咖啡因、咖啡酰奎宁酸异构体(CQA)、N-甲基吡啶、三尖杉碱和 5-羟甲基糠醛(HMF)中的应用进行了评估。采用 PULCON 方法(基于脉冲长度的浓度测定法)进行自动分析,实现了同时定量测定。该方法在线性、准确度、精密度、检出限(LOD)和定量限(LOQ)方面都得到了验证。回收率在 76%(CQA)和 116%(HMF)之间,精密度在 1.7%(咖啡因)和 10.3%(HMF)之间。检测限介于 0.06 克/千克(HMF)和 1.35 克/千克(咖啡因和 CQA)之间,最低检测限介于 0.22 克/千克(HMF)和 4.87 克/千克(CQA)之间。为了验证 1H-NMR 方法的结果,还采用 HPLC-DAD 方法对咖啡因、三尖杉碱、HMF、3-CQA、4-CQA 和 5-CQA 进行了定量分析,并对结果进行了比较。所述 1H-NMR 方法还被用于含有不同咖啡缺陷的咖啡样品。结果表明,将有缺陷的咖啡豆添加到无缺陷的咖啡中,分析物的浓度只会发生轻微的变化。因此,该方法非常适合在质量控制等工作中分析大量样品中的多种咖啡成分。本文受版权保护。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Fully automatic quantitation of eight different metabolites in coffee using 1H-NMR spectroscopy and the PULCON methodology

Background

Coffee contains a plethora of constituents with some of them being especially important either due to their physiological effects or as quality markers. As quantitative proton nuclear magnetic resonance spectroscopy (1H-NMR) has been established as a fast and reliable analytical tool its application was evaluated for the simultaneous quantitation of lactic acid, acetic acid, formic acid, caffeine, caffeoylquinic acid (CQA) isomers, N-methylpyridinium, trigonelline, and 5-hydroxymethylfurfural (HMF) in aqueous extracts of roasted Coffea arabica samples.

Results

Simultaneous quantitative determination was achieved by an automated analysis based on the PULCON methodology (pulse length-based concentration determination). The method was validated regarding linearity, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ). Recovery rates were between 76% (CQA) and 116% (HMF), and precision was between 1.7% (caffeine) and 10.3% (HMF). The LOD varied between 0.06 g/kg (HMF) and 1.35 g/kg (caffeine and CQA), with the LOQ being between 0.22 g/kg (HMF) and 4.87 g/kg (CQA). To verify the results of the 1H-NMR method, caffeine, trigonelline, HMF, 3-CQA, 4-CQA, and 5-CQA were additionally quantitated by HPLC-DAD and the results were compared. The described 1H-NMR method was additionally applied to coffee samples that contained different coffee defects. Results showed only slight changes in the concentrations of the analytes by adding defective beans to defect-free coffee.

Discussion

The developed 1H-NMR approach was proven to be fast (30 min), reliable, and precise. Thus, it is well suited to analyze several coffee constituents of interest in a large number of samples in, for example, quality control.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Issue Information Ultrasonic-assisted extraction of bioactive compounds from eggplant (Solanum melongena L.) calyx and evaluation of extract properties Sensory, proximate, and microbiological quality evaluation of five commercially important native and imported dry fish in Bangladesh Nitrogen rates shaping rice yield and groundwater nitrate in the Jamuna River basin of north central Bangladesh Genetic variability studies for qualitative and quantitative traits in some recently developed rice varieties of Bangladesh
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1