{"title":"股骨近端骨折固定术中辐照增加的相关因素。","authors":"A Elbahi, O Thomas, M Dungey, C Randall, D K Menon","doi":"10.1308/rcsann.2023.0092","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>When using radiation intraoperatively, a surgeon should aim to keep the radiation dose as low as is reasonably achievable to obtain the therapeutic goal. We aimed to investigate factors associated with increased radiation exposure in fixation of proximal femur fractures.</p><p><strong>Methods: </strong>We assessed 369 neck of femur fractures over a 1-year period in a district general hospital. All hip fracture subtypes that had undergone surgical fixation were included. We assessed the relationship between type of fracture, implants used and surgeon level of experience with the dose-area product (DAP; cGy/cm<sup>2</sup>) and screening time (dS). We also looked at the quality of reduction and fixation and its effect on the radiation exposure.</p><p><strong>Results: </strong>A total of 184 patients were included in our analysis; 185 patients who were treated with hip arthroplasty were excluded. There was a significant association between higher DAP and fracture subtype (<i>p</i> = 0.001), fracture complexity (<i>p</i> < 0.001), if an additional implant was used (<i>p</i> = 0.001), if fixation was satisfactory (<i>p</i> = 0.002) and operative time (<i>p</i> < 0.001). DAP was higher with a proximal femoral nail than with a dynamic hip screw, especially when a long nail was used. There was some evidence of an association between the surgeon's level of experience and DAP exposure, although this was not statistically significant (<i>p</i> = 0.069).</p><p><strong>Conclusions: </strong>Increased radiation in proximal femur fractures is seen in the fixation of complex fractures, some subtypes, with certain types of implants used and if an additional implant was required. Surgeon seniority did not result in less radiation exposure, which is in contrast to other published studies.</p>","PeriodicalId":8088,"journal":{"name":"Annals of the Royal College of Surgeons of England","volume":" ","pages":"41-47"},"PeriodicalIF":1.1000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11658882/pdf/","citationCount":"0","resultStr":"{\"title\":\"Factors associated with increased radiation exposure in the fixation of proximal femoral fractures.\",\"authors\":\"A Elbahi, O Thomas, M Dungey, C Randall, D K Menon\",\"doi\":\"10.1308/rcsann.2023.0092\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>When using radiation intraoperatively, a surgeon should aim to keep the radiation dose as low as is reasonably achievable to obtain the therapeutic goal. We aimed to investigate factors associated with increased radiation exposure in fixation of proximal femur fractures.</p><p><strong>Methods: </strong>We assessed 369 neck of femur fractures over a 1-year period in a district general hospital. All hip fracture subtypes that had undergone surgical fixation were included. We assessed the relationship between type of fracture, implants used and surgeon level of experience with the dose-area product (DAP; cGy/cm<sup>2</sup>) and screening time (dS). We also looked at the quality of reduction and fixation and its effect on the radiation exposure.</p><p><strong>Results: </strong>A total of 184 patients were included in our analysis; 185 patients who were treated with hip arthroplasty were excluded. There was a significant association between higher DAP and fracture subtype (<i>p</i> = 0.001), fracture complexity (<i>p</i> < 0.001), if an additional implant was used (<i>p</i> = 0.001), if fixation was satisfactory (<i>p</i> = 0.002) and operative time (<i>p</i> < 0.001). DAP was higher with a proximal femoral nail than with a dynamic hip screw, especially when a long nail was used. There was some evidence of an association between the surgeon's level of experience and DAP exposure, although this was not statistically significant (<i>p</i> = 0.069).</p><p><strong>Conclusions: </strong>Increased radiation in proximal femur fractures is seen in the fixation of complex fractures, some subtypes, with certain types of implants used and if an additional implant was required. Surgeon seniority did not result in less radiation exposure, which is in contrast to other published studies.</p>\",\"PeriodicalId\":8088,\"journal\":{\"name\":\"Annals of the Royal College of Surgeons of England\",\"volume\":\" \",\"pages\":\"41-47\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11658882/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of the Royal College of Surgeons of England\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1308/rcsann.2023.0092\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/4/2 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of the Royal College of Surgeons of England","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1308/rcsann.2023.0092","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/2 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

导言:在术中使用放射线时,外科医生应尽可能降低放射剂量,以达到治疗目的。我们旨在研究股骨近端骨折固定术中辐射量增加的相关因素:我们在一家地区综合医院对 369 例股骨颈骨折进行了为期 1 年的评估。所有接受过手术固定的髋部骨折亚型均包括在内。我们评估了骨折类型、所用植入物和外科医生经验水平与剂量-面积乘积(DAP;cGy/cm2)和筛选时间(dS)之间的关系。我们还考察了复位和固定的质量及其对辐射照射的影响:共有 184 名患者被纳入我们的分析中,其中 185 名患者接受了髋关节置换术治疗,不包括在内。较高的DAP与骨折亚型(p = 0.001)、骨折复杂性(p < 0.001)、是否使用额外的植入物(p = 0.001)、固定是否满意(p = 0.002)和手术时间(p < 0.001)之间存在明显关联。股骨近端钉的DAP高于动态髋螺钉,尤其是使用长钉时。有证据表明,外科医生的经验水平与DAP暴露之间存在一定的联系,但这并不具有统计学意义(P = 0.069):结论:股骨近端骨折的辐射增加体现在复杂骨折的固定、某些亚型骨折、使用某些类型的植入物以及需要额外植入物时。外科医生的资历并不会减少辐射量,这与其他已发表的研究结果不同。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Factors associated with increased radiation exposure in the fixation of proximal femoral fractures.

Introduction: When using radiation intraoperatively, a surgeon should aim to keep the radiation dose as low as is reasonably achievable to obtain the therapeutic goal. We aimed to investigate factors associated with increased radiation exposure in fixation of proximal femur fractures.

Methods: We assessed 369 neck of femur fractures over a 1-year period in a district general hospital. All hip fracture subtypes that had undergone surgical fixation were included. We assessed the relationship between type of fracture, implants used and surgeon level of experience with the dose-area product (DAP; cGy/cm2) and screening time (dS). We also looked at the quality of reduction and fixation and its effect on the radiation exposure.

Results: A total of 184 patients were included in our analysis; 185 patients who were treated with hip arthroplasty were excluded. There was a significant association between higher DAP and fracture subtype (p = 0.001), fracture complexity (p < 0.001), if an additional implant was used (p = 0.001), if fixation was satisfactory (p = 0.002) and operative time (p < 0.001). DAP was higher with a proximal femoral nail than with a dynamic hip screw, especially when a long nail was used. There was some evidence of an association between the surgeon's level of experience and DAP exposure, although this was not statistically significant (p = 0.069).

Conclusions: Increased radiation in proximal femur fractures is seen in the fixation of complex fractures, some subtypes, with certain types of implants used and if an additional implant was required. Surgeon seniority did not result in less radiation exposure, which is in contrast to other published studies.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.40
自引率
0.00%
发文量
316
期刊介绍: The Annals of The Royal College of Surgeons of England is the official scholarly research journal of the Royal College of Surgeons and is published eight times a year in January, February, March, April, May, July, September and November. The main aim of the journal is to publish high-quality, peer-reviewed papers that relate to all branches of surgery. The Annals also includes letters and comments, a regular technical section, controversial topics, CORESS feedback and book reviews. The editorial board is composed of experts from all the surgical specialties.
期刊最新文献
Metastases from gastric cancer presenting as colorectal lesions: a report of two cases and systematic review. Suprascapular nerve injury during robot-assisted radical prostatectomy: a case report. Injection sclerotherapy for the treatment of haemorrhoids in anticoagulated patients. The provision of a trauma bed in theatre recovery and its impact on trauma theatre efficiency: experience from a high-volume trauma unit. A national survey of practice for the emergency fixation of testis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1