使用新型泪膜成像仪检查泪膜动态。

IF 1.9 3区 医学 Q2 OPHTHALMOLOGY Cornea Pub Date : 2024-12-01 Epub Date: 2024-03-28 DOI:10.1097/ICO.0000000000003529
Simran Mangwani-Mordani, Drew Baeza, Kelly Acuna, Gal Antman, Alon Harris, Anat Galor
{"title":"使用新型泪膜成像仪检查泪膜动态。","authors":"Simran Mangwani-Mordani, Drew Baeza, Kelly Acuna, Gal Antman, Alon Harris, Anat Galor","doi":"10.1097/ICO.0000000000003529","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this study was to examine Tear Film Imager (TFI, AdOM, Israel) generated parameters across controls and dry eye (DE) subgroups and examine the changes in TFI parameters with contact lens (CL) placement.</p><p><strong>Methods: </strong>The retrospective study (n = 48) was conducted at the Miami Veterans Hospital. Symptoms were assessed through validated questionnaires and signs of tear function by tear break-up time and Schirmer scores. Participants were grouped as 1) healthy, 2) evaporative, 3) aqueous deficient, and 4) mixed DE based on tear function. Seventeen individuals had a baseline scan and a repeat scan following CL placement. Descriptives were compared across groups and over time.</p><p><strong>Results: </strong>The median age was 27 years, 74% self-identified as White, 45% as male, and 51% as Hispanic. Subjects in the aqueous deficiency category had lower muco-aqueous layer thickness (MALT) (2672 vs. 3084 nm) but higher lipid layer thickness (47.5 vs. 38.3 nm), lipid break-up time (4.4 vs. 2 seconds), and interblink interval (13.9 vs. 5.4 seconds) compared with the evaporative group. Subjects in the evaporative group had the highest MALT values (3084 vs. 2988, 2672, 3053 nm) compared with healthy, aqueous-deficient, and mixed groups. Symptoms were not significantly correlated with TFI parameters. CL placement significantly decreased MALT values (2869 → 2175 nm, P = 0.001).</p><p><strong>Conclusions: </strong>The TFI provides unique information regarding the dynamic function of the tear film not captured by clinical examination. TFI generated metrics demonstrate a thinner aqueous layer in individuals with aqueous deficiency but highlight a thicker aqueous layer in those with evaporative DE.</p>","PeriodicalId":10710,"journal":{"name":"Cornea","volume":" ","pages":"1547-1554"},"PeriodicalIF":1.9000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11436477/pdf/","citationCount":"0","resultStr":"{\"title\":\"Examining Tear Film Dynamics Using the Novel Tear Film Imager.\",\"authors\":\"Simran Mangwani-Mordani, Drew Baeza, Kelly Acuna, Gal Antman, Alon Harris, Anat Galor\",\"doi\":\"10.1097/ICO.0000000000003529\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The purpose of this study was to examine Tear Film Imager (TFI, AdOM, Israel) generated parameters across controls and dry eye (DE) subgroups and examine the changes in TFI parameters with contact lens (CL) placement.</p><p><strong>Methods: </strong>The retrospective study (n = 48) was conducted at the Miami Veterans Hospital. Symptoms were assessed through validated questionnaires and signs of tear function by tear break-up time and Schirmer scores. Participants were grouped as 1) healthy, 2) evaporative, 3) aqueous deficient, and 4) mixed DE based on tear function. Seventeen individuals had a baseline scan and a repeat scan following CL placement. Descriptives were compared across groups and over time.</p><p><strong>Results: </strong>The median age was 27 years, 74% self-identified as White, 45% as male, and 51% as Hispanic. Subjects in the aqueous deficiency category had lower muco-aqueous layer thickness (MALT) (2672 vs. 3084 nm) but higher lipid layer thickness (47.5 vs. 38.3 nm), lipid break-up time (4.4 vs. 2 seconds), and interblink interval (13.9 vs. 5.4 seconds) compared with the evaporative group. Subjects in the evaporative group had the highest MALT values (3084 vs. 2988, 2672, 3053 nm) compared with healthy, aqueous-deficient, and mixed groups. Symptoms were not significantly correlated with TFI parameters. CL placement significantly decreased MALT values (2869 → 2175 nm, P = 0.001).</p><p><strong>Conclusions: </strong>The TFI provides unique information regarding the dynamic function of the tear film not captured by clinical examination. TFI generated metrics demonstrate a thinner aqueous layer in individuals with aqueous deficiency but highlight a thicker aqueous layer in those with evaporative DE.</p>\",\"PeriodicalId\":10710,\"journal\":{\"name\":\"Cornea\",\"volume\":\" \",\"pages\":\"1547-1554\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11436477/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cornea\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/ICO.0000000000003529\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/28 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cornea","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/ICO.0000000000003529","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/28 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在检查泪膜成像仪(TFI,以色列 AdOM 公司)在对照组和干眼症(DE)亚组中生成的参数,并检查 TFI 参数随隐形眼镜(CL)配戴的变化情况:回顾性研究(n = 48)在迈阿密退伍军人医院进行。通过有效问卷对症状进行评估,通过泪液破裂时间和施尔默评分对泪液功能迹象进行评估。根据泪液功能将参与者分为 1) 健康型、2) 蒸发型、3) 水份缺乏型和 4) 混合 DE 型。17 人进行了基线扫描,并在植入 CL 后进行了重复扫描。对不同组别和不同时间段的描述进行了比较:中位年龄为 27 岁,74% 自认为是白人,45% 为男性,51% 为西班牙裔。与蒸发组相比,缺水组受试者的粘液层厚度(MALT)(2672 nm 对 3084 nm)较低,但脂质层厚度(47.5 nm 对 38.3 nm)、脂质破裂时间(4.4 秒对 2 秒)和链接间隔(13.9 秒对 5.4 秒)较高。与健康组、缺水组和混合组相比,蒸发组受试者的 MALT 值最高(3084 对 2988、2672 和 3053 纳米)。症状与 TFI 参数无明显相关性。CL置入可明显降低 MALT 值(2869 → 2175 nm,P = 0.001):TFI提供了临床检查无法捕捉到的有关泪膜动态功能的独特信息。TFI 生成的指标显示,水缺乏症患者的水层较薄,但蒸发性 DE 患者的水层较厚。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Examining Tear Film Dynamics Using the Novel Tear Film Imager.

Purpose: The purpose of this study was to examine Tear Film Imager (TFI, AdOM, Israel) generated parameters across controls and dry eye (DE) subgroups and examine the changes in TFI parameters with contact lens (CL) placement.

Methods: The retrospective study (n = 48) was conducted at the Miami Veterans Hospital. Symptoms were assessed through validated questionnaires and signs of tear function by tear break-up time and Schirmer scores. Participants were grouped as 1) healthy, 2) evaporative, 3) aqueous deficient, and 4) mixed DE based on tear function. Seventeen individuals had a baseline scan and a repeat scan following CL placement. Descriptives were compared across groups and over time.

Results: The median age was 27 years, 74% self-identified as White, 45% as male, and 51% as Hispanic. Subjects in the aqueous deficiency category had lower muco-aqueous layer thickness (MALT) (2672 vs. 3084 nm) but higher lipid layer thickness (47.5 vs. 38.3 nm), lipid break-up time (4.4 vs. 2 seconds), and interblink interval (13.9 vs. 5.4 seconds) compared with the evaporative group. Subjects in the evaporative group had the highest MALT values (3084 vs. 2988, 2672, 3053 nm) compared with healthy, aqueous-deficient, and mixed groups. Symptoms were not significantly correlated with TFI parameters. CL placement significantly decreased MALT values (2869 → 2175 nm, P = 0.001).

Conclusions: The TFI provides unique information regarding the dynamic function of the tear film not captured by clinical examination. TFI generated metrics demonstrate a thinner aqueous layer in individuals with aqueous deficiency but highlight a thicker aqueous layer in those with evaporative DE.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Cornea
Cornea 医学-眼科学
CiteScore
5.20
自引率
10.70%
发文量
354
审稿时长
3-6 weeks
期刊介绍: For corneal specialists and for all general ophthalmologists with an interest in this exciting subspecialty, Cornea brings together the latest clinical and basic research on the cornea and the anterior segment of the eye. Each volume is peer-reviewed by Cornea''s board of world-renowned experts and fully indexed in archival format. Your subscription brings you the latest developments in your field and a growing library of valuable professional references. Sponsored by The Cornea Society which was founded as the Castroviejo Cornea Society in 1975.
期刊最新文献
Evaluation of the German Version of the Keratoconus Outcomes Research Questionnaire. Modified Method for Nanothin Descemet Stripping Automated Endothelial Keratoplasty. Pseudopterygia in Fuchs Superficial Marginal Keratitis: Clinical Course and Surgical Outcomes. Baseline Participant Characteristics at Enrollment in the Zoster Eye Disease Study. Cornea Classics: Melles, Ong, Ververs, and van der Wees, "Descemet Membrane Endothelial Keratoplasty (DMEK)" (2006).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1