因干扰 PT PLN UP3 Gorontalo 公司电表而造成的非技术性缩水分析

F. Surusa, Qurrotul Aini, A. Pratiwi, Yasin Mohamad
{"title":"因干扰 PT PLN UP3 Gorontalo 公司电表而造成的非技术性缩水分析","authors":"F. Surusa, Qurrotul Aini, A. Pratiwi, Yasin Mohamad","doi":"10.37905/jjeee.v6i1.22380","DOIUrl":null,"url":null,"abstract":"Penelitian ini bertujuan untuk menghitung energi yang hilang akibat penanganan gangguan kWh meter prabayar pada tarif rumah tangga. Hasil penelitian menunjukkan bahwa kWh yang hilang akibat penanganan gangguan kWh meter prabayar secara sambung langsung selama 30 hari adalah sebesar 312.971,2 kWh. Total kerugian energi tersebut apabila dikonversi kedalam bentuk rupiah adalah sebesar Rp. 254.103.331,-. Susut akibat gangguan kWh meter prabayar menyumbang 0.18% dari 1.19% susut non teknis pada triwulan 1. Monitoring terhadap perputaran penggunaan material kwh meter prabayar cadangan di unit gangguan serta monitoring material yang tidak layak pakai merupakan salah satu cara untuk meminimalkan kerugian energi yang bersifat non teknis akibat gangguan pada meter prabayar tanpa sambung langsung.This study aims to calculate the energy lost due to the interference handling of kWh prepaid meters on household tariffs. The results showed that the kWh lost due to direct connection of kWh meter disturbances for 30 days was 312,971.2 kWh. The total energy loss when converted into rupiah is IDR 254,103,331. Losses due to disturbances in prepaid kWh meters accounted for 0.18% of the 1.19% non-technical losses in the 1st quarter. Monitoring the turnover of spare prepaid kWh meter materials in the disturbance unit, as well as monitoring ex-unloading materials, is one way to minimize non-technical energy losses due to disturbances on prepaid meters without a direct dial.","PeriodicalId":292481,"journal":{"name":"Jambura Journal of Electrical and Electronics Engineering","volume":"43 7","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analisis Susut Non Teknis Akibat Gangguan pada kWh Meter PT. PLN UP3 Gorontalo\",\"authors\":\"F. Surusa, Qurrotul Aini, A. Pratiwi, Yasin Mohamad\",\"doi\":\"10.37905/jjeee.v6i1.22380\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Penelitian ini bertujuan untuk menghitung energi yang hilang akibat penanganan gangguan kWh meter prabayar pada tarif rumah tangga. Hasil penelitian menunjukkan bahwa kWh yang hilang akibat penanganan gangguan kWh meter prabayar secara sambung langsung selama 30 hari adalah sebesar 312.971,2 kWh. Total kerugian energi tersebut apabila dikonversi kedalam bentuk rupiah adalah sebesar Rp. 254.103.331,-. Susut akibat gangguan kWh meter prabayar menyumbang 0.18% dari 1.19% susut non teknis pada triwulan 1. Monitoring terhadap perputaran penggunaan material kwh meter prabayar cadangan di unit gangguan serta monitoring material yang tidak layak pakai merupakan salah satu cara untuk meminimalkan kerugian energi yang bersifat non teknis akibat gangguan pada meter prabayar tanpa sambung langsung.This study aims to calculate the energy lost due to the interference handling of kWh prepaid meters on household tariffs. The results showed that the kWh lost due to direct connection of kWh meter disturbances for 30 days was 312,971.2 kWh. The total energy loss when converted into rupiah is IDR 254,103,331. Losses due to disturbances in prepaid kWh meters accounted for 0.18% of the 1.19% non-technical losses in the 1st quarter. Monitoring the turnover of spare prepaid kWh meter materials in the disturbance unit, as well as monitoring ex-unloading materials, is one way to minimize non-technical energy losses due to disturbances on prepaid meters without a direct dial.\",\"PeriodicalId\":292481,\"journal\":{\"name\":\"Jambura Journal of Electrical and Electronics Engineering\",\"volume\":\"43 7\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jambura Journal of Electrical and Electronics Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.37905/jjeee.v6i1.22380\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jambura Journal of Electrical and Electronics Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37905/jjeee.v6i1.22380","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在计算因处理预付费千瓦时电表干扰而造成的家庭电价能源损失。结果显示,30 天内因处理预付费电表干扰而直接损失的电量为 312,971.2 千瓦时。换算成印尼盾后,能源损失总量为 254 103 331 印尼盾。监测干扰单位备用预付费千瓦时电表材料的使用周转情况,并对不适合使用的材料进行监测,是最大限度减少因不直接连接预付费电表的干扰而造成的非技术性能源损失的方法之一。本研究旨在计算因家庭电价预付费千瓦时电表的干扰处理而造成的能源损失。结果显示,30 天内由于千瓦时电表直接连接干扰造成的千瓦时损失为 312971.2 千瓦时。换算成印尼盾后,能源损失总量为 254,103,331 印尼盾。在第一季度 1.19%的非技术性损失中,预付费千瓦时电表故障造成的损失占 0.18%。监控扰动单位备用预付费千瓦时电表材料的周转情况,以及监控材料的出库情况,是将预付费电表扰动造成的非技术性能源损失降至最低的一种方法,而无需直接拨号。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analisis Susut Non Teknis Akibat Gangguan pada kWh Meter PT. PLN UP3 Gorontalo
Penelitian ini bertujuan untuk menghitung energi yang hilang akibat penanganan gangguan kWh meter prabayar pada tarif rumah tangga. Hasil penelitian menunjukkan bahwa kWh yang hilang akibat penanganan gangguan kWh meter prabayar secara sambung langsung selama 30 hari adalah sebesar 312.971,2 kWh. Total kerugian energi tersebut apabila dikonversi kedalam bentuk rupiah adalah sebesar Rp. 254.103.331,-. Susut akibat gangguan kWh meter prabayar menyumbang 0.18% dari 1.19% susut non teknis pada triwulan 1. Monitoring terhadap perputaran penggunaan material kwh meter prabayar cadangan di unit gangguan serta monitoring material yang tidak layak pakai merupakan salah satu cara untuk meminimalkan kerugian energi yang bersifat non teknis akibat gangguan pada meter prabayar tanpa sambung langsung.This study aims to calculate the energy lost due to the interference handling of kWh prepaid meters on household tariffs. The results showed that the kWh lost due to direct connection of kWh meter disturbances for 30 days was 312,971.2 kWh. The total energy loss when converted into rupiah is IDR 254,103,331. Losses due to disturbances in prepaid kWh meters accounted for 0.18% of the 1.19% non-technical losses in the 1st quarter. Monitoring the turnover of spare prepaid kWh meter materials in the disturbance unit, as well as monitoring ex-unloading materials, is one way to minimize non-technical energy losses due to disturbances on prepaid meters without a direct dial.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Evaluasi Penerimaan Sistem Informasi ft.ung.ac.id dengan Pendekatan Metode TAM Analisis Konsumsi Energi Listrik Menggunakan Metode Internsitas Konsumsi Energi Transformasi Digital Teknik Telekomunikasi Dasar Dan Sistem Telekomunikasi Lanjut Determining Priorities for Bongo Nol Village Using the Hierarchy Process Analysis Approach Rancang Bangun Modul Praktikum Dasar-Dasar Teknik Digital
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1