利用对比增强超声波评估局灶性结节增生的引流静脉

IF 1.9 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Journal of Medical Ultrasonics Pub Date : 2024-04-12 DOI:10.1007/s10396-024-01451-x
Yukinobu Watanabe, Masahiro Ogawa, Aya Konishi, Seiichiro Suda, Yu Tamura, Masahiro Kaneko, Midori Hirayama, Naoki Matsumoto, Hirofumi Kogure
{"title":"利用对比增强超声波评估局灶性结节增生的引流静脉","authors":"Yukinobu Watanabe, Masahiro Ogawa, Aya Konishi, Seiichiro Suda, Yu Tamura, Masahiro Kaneko, Midori Hirayama, Naoki Matsumoto, Hirofumi Kogure","doi":"10.1007/s10396-024-01451-x","DOIUrl":null,"url":null,"abstract":"<h3 data-test=\"abstract-sub-heading\">Purpose</h3><p>Identification of drainage vessels is useful for differential diagnosis of hepatic tumors. Direct drainage to the hepatic vein has been reported to occur in focal nodular hyperplasia (FNH), but studies evaluating the drainage veins of FNH are limited. We aimed to investigate the detection rate of the FNH drainage vein and the factors related to visualization of the drainage vein on contrast-enhanced ultrasound (CEUS).</p><h3 data-test=\"abstract-sub-heading\">Methods</h3><p>Fifty consecutive patients with 50 FNH lesions were retrospectively evaluated in this study. We calculated and compared the detection rate of the FNH drainage vein on CEUS, contrast-enhanced magnetic resonance imaging (CEMRI), and contrast-enhanced computed tomography (CECT), and identified the factors correlated with visualization of the FNH drainage vein on CEUS by using multivariate logistic regression analyses.</p><h3 data-test=\"abstract-sub-heading\">Results</h3><p>Visualization of the drainage vein was confirmed in 31 of 50 lesions (62%) using CEUS, three of 44 lesions (6.8%) using CEMRI, and one of 18 lesions (5.6%) using CECT. The detection rate of the FNH drainage vein on CEUS was significantly higher than that on CEMRI and CECT (<i>p</i> &lt; 0.001). Multivariate analysis identified lesion size (≥ 25 mm) and detection of the spoke-wheel pattern on Doppler US as independent factors for drainage vein detection in FNH.</p><h3 data-test=\"abstract-sub-heading\">Conclusion</h3><p>Our study showed that rapid FNH drainage to the hepatic vein was observed at a relatively high rate on CEUS, suggesting that CEUS focusing on detection of drainage veins is important for diagnosing FNH.</p>","PeriodicalId":50130,"journal":{"name":"Journal of Medical Ultrasonics","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2024-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of drainage vein of focal nodular hyperplasia using contrast-enhanced ultrasound\",\"authors\":\"Yukinobu Watanabe, Masahiro Ogawa, Aya Konishi, Seiichiro Suda, Yu Tamura, Masahiro Kaneko, Midori Hirayama, Naoki Matsumoto, Hirofumi Kogure\",\"doi\":\"10.1007/s10396-024-01451-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<h3 data-test=\\\"abstract-sub-heading\\\">Purpose</h3><p>Identification of drainage vessels is useful for differential diagnosis of hepatic tumors. Direct drainage to the hepatic vein has been reported to occur in focal nodular hyperplasia (FNH), but studies evaluating the drainage veins of FNH are limited. We aimed to investigate the detection rate of the FNH drainage vein and the factors related to visualization of the drainage vein on contrast-enhanced ultrasound (CEUS).</p><h3 data-test=\\\"abstract-sub-heading\\\">Methods</h3><p>Fifty consecutive patients with 50 FNH lesions were retrospectively evaluated in this study. We calculated and compared the detection rate of the FNH drainage vein on CEUS, contrast-enhanced magnetic resonance imaging (CEMRI), and contrast-enhanced computed tomography (CECT), and identified the factors correlated with visualization of the FNH drainage vein on CEUS by using multivariate logistic regression analyses.</p><h3 data-test=\\\"abstract-sub-heading\\\">Results</h3><p>Visualization of the drainage vein was confirmed in 31 of 50 lesions (62%) using CEUS, three of 44 lesions (6.8%) using CEMRI, and one of 18 lesions (5.6%) using CECT. The detection rate of the FNH drainage vein on CEUS was significantly higher than that on CEMRI and CECT (<i>p</i> &lt; 0.001). Multivariate analysis identified lesion size (≥ 25 mm) and detection of the spoke-wheel pattern on Doppler US as independent factors for drainage vein detection in FNH.</p><h3 data-test=\\\"abstract-sub-heading\\\">Conclusion</h3><p>Our study showed that rapid FNH drainage to the hepatic vein was observed at a relatively high rate on CEUS, suggesting that CEUS focusing on detection of drainage veins is important for diagnosing FNH.</p>\",\"PeriodicalId\":50130,\"journal\":{\"name\":\"Journal of Medical Ultrasonics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-04-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Ultrasonics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10396-024-01451-x\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Ultrasonics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10396-024-01451-x","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的确定引流血管有助于肝脏肿瘤的鉴别诊断。有报道称局灶性结节性增生(FNH)会出现肝静脉直接引流,但评估 FNH 引流静脉的研究却很有限。我们旨在研究 FNH 引流静脉的检出率以及造影剂增强超声(CEUS)显示引流静脉的相关因素。我们计算并比较了 CEUS、造影剂增强磁共振成像(CEMRI)和造影剂增强计算机断层扫描(CECT)对 FNH 引流静脉的检出率,并通过多变量逻辑回归分析确定了与 CEUS 检出 FNH 引流静脉相关的因素。结果50个病灶中有31个(62%)通过CEUS确认了引流静脉的可见性,44个病灶中有3个(6.8%)通过CEMRI确认了引流静脉的可见性,18个病灶中有1个(5.6%)通过CECT确认了引流静脉的可见性。CEUS 对 FNH 引流静脉的检出率明显高于 CEMRI 和 CECT(P < 0.001)。多变量分析确定病灶大小(≥ 25 mm)和多普勒超声检测到的辐轮模式是 FNH 引流静脉检测的独立因素。结论我们的研究表明,CEUS 上观察到 FNH 快速引流至肝静脉的比率相对较高,这表明 CEUS 重点检测引流静脉对诊断 FNH 非常重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Assessment of drainage vein of focal nodular hyperplasia using contrast-enhanced ultrasound

Purpose

Identification of drainage vessels is useful for differential diagnosis of hepatic tumors. Direct drainage to the hepatic vein has been reported to occur in focal nodular hyperplasia (FNH), but studies evaluating the drainage veins of FNH are limited. We aimed to investigate the detection rate of the FNH drainage vein and the factors related to visualization of the drainage vein on contrast-enhanced ultrasound (CEUS).

Methods

Fifty consecutive patients with 50 FNH lesions were retrospectively evaluated in this study. We calculated and compared the detection rate of the FNH drainage vein on CEUS, contrast-enhanced magnetic resonance imaging (CEMRI), and contrast-enhanced computed tomography (CECT), and identified the factors correlated with visualization of the FNH drainage vein on CEUS by using multivariate logistic regression analyses.

Results

Visualization of the drainage vein was confirmed in 31 of 50 lesions (62%) using CEUS, three of 44 lesions (6.8%) using CEMRI, and one of 18 lesions (5.6%) using CECT. The detection rate of the FNH drainage vein on CEUS was significantly higher than that on CEMRI and CECT (p < 0.001). Multivariate analysis identified lesion size (≥ 25 mm) and detection of the spoke-wheel pattern on Doppler US as independent factors for drainage vein detection in FNH.

Conclusion

Our study showed that rapid FNH drainage to the hepatic vein was observed at a relatively high rate on CEUS, suggesting that CEUS focusing on detection of drainage veins is important for diagnosing FNH.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.30
自引率
11.10%
发文量
102
审稿时长
>12 weeks
期刊介绍: The Journal of Medical Ultrasonics is the official journal of the Japan Society of Ultrasonics in Medicine. The main purpose of the journal is to provide forum for the publication of papers documenting recent advances and new developments in the entire field of ultrasound in medicine and biology, encompassing both the medical and the engineering aspects of the science.The journal welcomes original articles, review articles, images, and letters to the editor.The journal also provides state-of-the-art information such as announcements from the boards and the committees of the society.
期刊最新文献
Correction: Principle of contrast-enhanced ultrasonography. Evaluation under loading detects medial meniscus extrusion in patients with reconstructed anterior cruciate ligament and restricted knee extension. Resolution of oval thrombus in a case of external jugular venous aneurysm. Quantification of the size of subchorionic hematoma causing pregnancy-related complications: a retrospective cohort study. Correction: Third-look contrast-enhanced ultrasonography plus needle biopsy for differential diagnosis of magnetic resonance imaging-only detected breast lesions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1