介质截流膜对不受控制的糖尿病血液透析患者体内喷托苷和 N-(羧甲基)赖氨酸水平的影响

IF 1.5 4区 医学 Q3 HEMATOLOGY Therapeutic Apheresis and Dialysis Pub Date : 2024-04-04 DOI:10.1111/1744-9987.14126
Neriman Sıla Koç, Hasan Yeter, Tolga Yıldırım, Yunus Erdem, Rahmi Yılmaz
{"title":"介质截流膜对不受控制的糖尿病血液透析患者体内喷托苷和 N-(羧甲基)赖氨酸水平的影响","authors":"Neriman Sıla Koç, Hasan Yeter, Tolga Yıldırım, Yunus Erdem, Rahmi Yılmaz","doi":"10.1111/1744-9987.14126","DOIUrl":null,"url":null,"abstract":"IntroductionPatients on hemodialysis, especially with diabetes, face elevated cardiovascular events. A major contributor to complications associated with diabetes is advanced glycation end products (AGEs). Removing these compounds is challenging in traditional hemodialysis. Medium‐cut‐off (MCO) membranes potentially remove toxins without significant albumin loss. This study explored how MCO membranes impact AGEs levels in uncontrolled diabetic patients undergoing hemodialysis.MethodsSixteen patients received MCO membrane dialysis, while others used high‐flux (HF) membranes. After 12 sessions, the dialyzers were switched, totaling 24 sessions. Blood samples at trial initiation (T0), session 12 (T1) and session 24 (T2) tested for CML, Pentosidine, laboratory parameters.ResultsSwitching dialyzers showed increased albumin with MCO‐to‐HF and decreased with HF‐to‐MCO, albeit nonsignificant (<jats:italic>p</jats:italic> = 0.5/<jats:italic>p</jats:italic> = 0.1). Patients on MCO had lower albumin levels than HF (<jats:italic>p</jats:italic> = 0.03/<jats:italic>p</jats:italic> = 0.6, respectively). Hemodialysis with MCO demonstrated lower levels of CML/Pentosidine compared to HF (<jats:italic>p</jats:italic> = 0.09/<jats:italic>p</jats:italic> = 0.9 for CML; <jats:italic>p</jats:italic> = 0.04/<jats:italic>p</jats:italic> = 0.3 for Pentosidine). Transitioning to HF led to elevated levels (<jats:italic>p</jats:italic> = 0.4/<jats:italic>p</jats:italic> = 0.09 for CML; <jats:italic>p</jats:italic> = 0.3/<jats:italic>p</jats:italic> = 0.07 for Pentosidine).ConclusionMCO dialysis in diabetic individuals notably reduces AGE levels.","PeriodicalId":23021,"journal":{"name":"Therapeutic Apheresis and Dialysis","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2024-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of medium cut‐off membranes on Pentosidine and N‐(carboxymethyl) lysine levels in uncontrolled diabetic hemodialysis patients\",\"authors\":\"Neriman Sıla Koç, Hasan Yeter, Tolga Yıldırım, Yunus Erdem, Rahmi Yılmaz\",\"doi\":\"10.1111/1744-9987.14126\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"IntroductionPatients on hemodialysis, especially with diabetes, face elevated cardiovascular events. A major contributor to complications associated with diabetes is advanced glycation end products (AGEs). Removing these compounds is challenging in traditional hemodialysis. Medium‐cut‐off (MCO) membranes potentially remove toxins without significant albumin loss. This study explored how MCO membranes impact AGEs levels in uncontrolled diabetic patients undergoing hemodialysis.MethodsSixteen patients received MCO membrane dialysis, while others used high‐flux (HF) membranes. After 12 sessions, the dialyzers were switched, totaling 24 sessions. Blood samples at trial initiation (T0), session 12 (T1) and session 24 (T2) tested for CML, Pentosidine, laboratory parameters.ResultsSwitching dialyzers showed increased albumin with MCO‐to‐HF and decreased with HF‐to‐MCO, albeit nonsignificant (<jats:italic>p</jats:italic> = 0.5/<jats:italic>p</jats:italic> = 0.1). Patients on MCO had lower albumin levels than HF (<jats:italic>p</jats:italic> = 0.03/<jats:italic>p</jats:italic> = 0.6, respectively). Hemodialysis with MCO demonstrated lower levels of CML/Pentosidine compared to HF (<jats:italic>p</jats:italic> = 0.09/<jats:italic>p</jats:italic> = 0.9 for CML; <jats:italic>p</jats:italic> = 0.04/<jats:italic>p</jats:italic> = 0.3 for Pentosidine). Transitioning to HF led to elevated levels (<jats:italic>p</jats:italic> = 0.4/<jats:italic>p</jats:italic> = 0.09 for CML; <jats:italic>p</jats:italic> = 0.3/<jats:italic>p</jats:italic> = 0.07 for Pentosidine).ConclusionMCO dialysis in diabetic individuals notably reduces AGE levels.\",\"PeriodicalId\":23021,\"journal\":{\"name\":\"Therapeutic Apheresis and Dialysis\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-04-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Therapeutic Apheresis and Dialysis\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/1744-9987.14126\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Therapeutic Apheresis and Dialysis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/1744-9987.14126","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

导言血液透析患者,尤其是糖尿病患者,面临着心血管事件的增加。导致糖尿病并发症的一个主要因素是高级糖化终产物(AGEs)。在传统的血液透析中,清除这些化合物是一项挑战。中截留(MCO)膜有可能在不损失大量白蛋白的情况下清除毒素。本研究探讨了 MCO 膜如何影响接受血液透析的未控制糖尿病患者体内的 AGEs 水平。12次透析后,更换透析器,共进行了24次透析。在试验开始时(T0)、第 12 次(T1)和第 24 次(T2)采集的血样检测了 CML、喷托苷和实验室参数。MCO 患者的白蛋白水平低于 HF(分别为 p = 0.03/p = 0.6)。与高频透析相比,接受 MCO 血液透析的患者白蛋白/喷托西汀水平较低(白蛋白 p = 0.09/p = 0.9;喷托西汀 p = 0.04/p = 0.3)。转为高频透析后,AGE 水平升高(CML 的 p = 0.4/p = 0.09;喷托西啶的 p = 0.3/p = 0.07)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of medium cut‐off membranes on Pentosidine and N‐(carboxymethyl) lysine levels in uncontrolled diabetic hemodialysis patients
IntroductionPatients on hemodialysis, especially with diabetes, face elevated cardiovascular events. A major contributor to complications associated with diabetes is advanced glycation end products (AGEs). Removing these compounds is challenging in traditional hemodialysis. Medium‐cut‐off (MCO) membranes potentially remove toxins without significant albumin loss. This study explored how MCO membranes impact AGEs levels in uncontrolled diabetic patients undergoing hemodialysis.MethodsSixteen patients received MCO membrane dialysis, while others used high‐flux (HF) membranes. After 12 sessions, the dialyzers were switched, totaling 24 sessions. Blood samples at trial initiation (T0), session 12 (T1) and session 24 (T2) tested for CML, Pentosidine, laboratory parameters.ResultsSwitching dialyzers showed increased albumin with MCO‐to‐HF and decreased with HF‐to‐MCO, albeit nonsignificant (p = 0.5/p = 0.1). Patients on MCO had lower albumin levels than HF (p = 0.03/p = 0.6, respectively). Hemodialysis with MCO demonstrated lower levels of CML/Pentosidine compared to HF (p = 0.09/p = 0.9 for CML; p = 0.04/p = 0.3 for Pentosidine). Transitioning to HF led to elevated levels (p = 0.4/p = 0.09 for CML; p = 0.3/p = 0.07 for Pentosidine).ConclusionMCO dialysis in diabetic individuals notably reduces AGE levels.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Therapeutic Apheresis and Dialysis
Therapeutic Apheresis and Dialysis 医学-泌尿学与肾脏学
CiteScore
3.00
自引率
10.50%
发文量
166
审稿时长
6-12 weeks
期刊介绍: Therapeutic Apheresis and Dialysis is the official peer-reviewed journal of the International Society for Apheresis, the Japanese Society for Apheresis and the Japanese Society for Dialysis Therapy. The Journal publishes original articles, editorial comments, review articles, case reports, meeting abstracts and Communications information on apheresis and dialysis technologies and treatments.
期刊最新文献
Fear of falling and associated influencing factors in patients on maintenance hemodialysis Enhancing hepatitis C management in ESRD: Evaluating efficacy and safety of alternative antiviral regimens Therapeutic Apheresis and Dialysis Forthcoming Events October 2024 Therapeutic Apheresis and Dialysis Forthcoming Events August 2024 Validity and reliability of the Turkish version of the patient on hemodialysis resilience scale
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1