{"title":"使用 CFAST 软件模拟布什尔核电站主控室的火灾情况","authors":"Sahar Mojab, Ehsan Zarifi, Saeed Zare Ganjaroodi, Gholamreza Jahanfarnia","doi":"10.1007/s10512-024-01071-1","DOIUrl":null,"url":null,"abstract":"<p>Fire protection is one of the most important issues to ensure safety and reduce risks of nuclear power plants. The main control room (MCR) is one of the parts of a nuclear power plant that is often identified with a high risk of fire in safety assessments. Although robust programs to shut down commercial reactors in any fires have been successfully maintained, the purpose of this paper is to simulate the fire in the MCR of Bushehr nuclear power plant unit‑1 (BNPP-1) using CFAST software. CFAST is a two-zone fire model used to calculate the evolving distribution of smoke, fire gases, and temperature throughout the compartments of a building during a fire. The data required for simulation have been extracted from final safety analysis reports and operating documents of BNPP‑1 and NUREG6850 reports. The results showed that the highest recorded temperature was related to the upper part of the standing cabinet about 1013 °C, which is the result of flames as well as heat transfer through smoke. Also, the other highest recorded temperature was in the lower part of the standing cabinet about 700 °C. Finally, the first ventilation system was closed for about 350 s and the second ventilation system was closed for about 860 s after the fire started.</p>","PeriodicalId":480,"journal":{"name":"Atomic Energy","volume":null,"pages":null},"PeriodicalIF":0.4000,"publicationDate":"2024-04-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fire simulation in the main control room of Bushehr nuclear power plant using CFAST software\",\"authors\":\"Sahar Mojab, Ehsan Zarifi, Saeed Zare Ganjaroodi, Gholamreza Jahanfarnia\",\"doi\":\"10.1007/s10512-024-01071-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Fire protection is one of the most important issues to ensure safety and reduce risks of nuclear power plants. The main control room (MCR) is one of the parts of a nuclear power plant that is often identified with a high risk of fire in safety assessments. Although robust programs to shut down commercial reactors in any fires have been successfully maintained, the purpose of this paper is to simulate the fire in the MCR of Bushehr nuclear power plant unit‑1 (BNPP-1) using CFAST software. CFAST is a two-zone fire model used to calculate the evolving distribution of smoke, fire gases, and temperature throughout the compartments of a building during a fire. The data required for simulation have been extracted from final safety analysis reports and operating documents of BNPP‑1 and NUREG6850 reports. The results showed that the highest recorded temperature was related to the upper part of the standing cabinet about 1013 °C, which is the result of flames as well as heat transfer through smoke. Also, the other highest recorded temperature was in the lower part of the standing cabinet about 700 °C. Finally, the first ventilation system was closed for about 350 s and the second ventilation system was closed for about 860 s after the fire started.</p>\",\"PeriodicalId\":480,\"journal\":{\"name\":\"Atomic Energy\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2024-04-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Atomic Energy\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s10512-024-01071-1\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"NUCLEAR SCIENCE & TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Atomic Energy","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10512-024-01071-1","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

防火是确保核电站安全和降低风险的最重要问题之一。主控室(MCR)是核电厂的组成部分之一,在安全评估中通常被认为具有较高的火灾风险。尽管在任何火灾情况下都能成功关闭商业反应堆,但本文的目的是使用 CFAST 软件模拟布什尔核电站 1 号机组(BNPP-1)主控室的火灾。CFAST 是一种双区火灾模型,用于计算火灾期间烟雾、火灾气体和温度在建筑物各隔间内的演变分布情况。模拟所需的数据摘自 BNPP-1 的最终安全分析报告和运行文件以及 NUREG6850 报告。结果显示,记录到的最高温度与立柜上部有关,约为 1013 ℃,这是火焰以及通过烟雾传热的结果。此外,另一个记录到的最高温度位于立柜的下部,约为 700 °C。最后,火灾发生后,第一套通风系统关闭了约 350 秒,第二套通风系统关闭了约 860 秒。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Fire simulation in the main control room of Bushehr nuclear power plant using CFAST software

Fire protection is one of the most important issues to ensure safety and reduce risks of nuclear power plants. The main control room (MCR) is one of the parts of a nuclear power plant that is often identified with a high risk of fire in safety assessments. Although robust programs to shut down commercial reactors in any fires have been successfully maintained, the purpose of this paper is to simulate the fire in the MCR of Bushehr nuclear power plant unit‑1 (BNPP-1) using CFAST software. CFAST is a two-zone fire model used to calculate the evolving distribution of smoke, fire gases, and temperature throughout the compartments of a building during a fire. The data required for simulation have been extracted from final safety analysis reports and operating documents of BNPP‑1 and NUREG6850 reports. The results showed that the highest recorded temperature was related to the upper part of the standing cabinet about 1013 °C, which is the result of flames as well as heat transfer through smoke. Also, the other highest recorded temperature was in the lower part of the standing cabinet about 700 °C. Finally, the first ventilation system was closed for about 350 s and the second ventilation system was closed for about 860 s after the fire started.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Atomic Energy
Atomic Energy 工程技术-核科学技术
CiteScore
1.00
自引率
20.00%
发文量
100
审稿时长
4-8 weeks
期刊介绍: Atomic Energy publishes papers and review articles dealing with the latest developments in the peaceful uses of atomic energy. Topics include nuclear chemistry and physics, plasma physics, accelerator characteristics, reactor economics and engineering, applications of isotopes, and radiation monitoring and safety.
期刊最新文献
Prospects for fusion neutron sources in the Russian nuclear power industry Use of a refueling machine mast sipping system to detect leaking FAs during operational fuel cladding failure detection Approaches to slowing down the kinetics of a fast reactor as a means of enhancing its self-protection properties Study into the possibility of using two groups of accelerated preventive protection for VVER-1200 reactors Accounting for the reference data correlation when determining the calculation error using the maximum likelihood method
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1