碳纤维/热塑性塑料 (PA6) 管状结构旋转拉弯成型的内部芯模设计比较

IF 2.3 4区 材料科学 Q3 MATERIALS SCIENCE, COMPOSITES Applied Composite Materials Pub Date : 2024-04-25 DOI:10.1007/s10443-024-10234-z
Mengyuan Li, Chris Stokes-Griffin, John Holmes, Silvano Sommacal, Paul Compston
{"title":"碳纤维/热塑性塑料 (PA6) 管状结构旋转拉弯成型的内部芯模设计比较","authors":"Mengyuan Li,&nbsp;Chris Stokes-Griffin,&nbsp;John Holmes,&nbsp;Silvano Sommacal,&nbsp;Paul Compston","doi":"10.1007/s10443-024-10234-z","DOIUrl":null,"url":null,"abstract":"<div><p>Carbon fibre reinforced thermoplastic tubular structures can be post-formed into desired curvatures via rotary draw bending (RDB) at elevated temperatures. During this process, a rigid internal mandrel is required to support the walls of the tubes to maintain their ovality and minimise unwanted geometrical distortions. This paper investigates four internal mandrel designs for post-forming carbon fiber reinforced polyamide 6 (CF/PA6) thermoplastic tubes. Mandrel designs include silicone rod, bullet, wire, and coil spring, were evaluated through RDB-forming experiments with [± 60°]<sub>4</sub> CF/PA6 tubes formed to 90° bends. The designs were evaluated for their effectiveness on minimising distortions resulted from induced stresses during post-forming by measuring the post-formed tube diameter and extrados strains. The mandrel designs were also evaluated for their usability when integrated into the RDB process. Results from optical measurements and micro-computed tomography showed the spring mandrel outperformed others, producing tubes with the least geometrical distortions and no defects during the forming process. As compared to other designs, the spring mandrel is a reusable unibody design that is easy to assemble and remove from the tubes.</p></div>","PeriodicalId":468,"journal":{"name":"Applied Composite Materials","volume":"31 4","pages":"1259 - 1273"},"PeriodicalIF":2.3000,"publicationDate":"2024-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s10443-024-10234-z.pdf","citationCount":"0","resultStr":"{\"title\":\"A Comparison of Internal Mandrel Designs for Rotary Draw Bend Forming of Carbon-fibre/Thermoplastic (PA6) Tubular Structures\",\"authors\":\"Mengyuan Li,&nbsp;Chris Stokes-Griffin,&nbsp;John Holmes,&nbsp;Silvano Sommacal,&nbsp;Paul Compston\",\"doi\":\"10.1007/s10443-024-10234-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Carbon fibre reinforced thermoplastic tubular structures can be post-formed into desired curvatures via rotary draw bending (RDB) at elevated temperatures. During this process, a rigid internal mandrel is required to support the walls of the tubes to maintain their ovality and minimise unwanted geometrical distortions. This paper investigates four internal mandrel designs for post-forming carbon fiber reinforced polyamide 6 (CF/PA6) thermoplastic tubes. Mandrel designs include silicone rod, bullet, wire, and coil spring, were evaluated through RDB-forming experiments with [± 60°]<sub>4</sub> CF/PA6 tubes formed to 90° bends. The designs were evaluated for their effectiveness on minimising distortions resulted from induced stresses during post-forming by measuring the post-formed tube diameter and extrados strains. The mandrel designs were also evaluated for their usability when integrated into the RDB process. Results from optical measurements and micro-computed tomography showed the spring mandrel outperformed others, producing tubes with the least geometrical distortions and no defects during the forming process. As compared to other designs, the spring mandrel is a reusable unibody design that is easy to assemble and remove from the tubes.</p></div>\",\"PeriodicalId\":468,\"journal\":{\"name\":\"Applied Composite Materials\",\"volume\":\"31 4\",\"pages\":\"1259 - 1273\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-04-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://link.springer.com/content/pdf/10.1007/s10443-024-10234-z.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Composite Materials\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s10443-024-10234-z\",\"RegionNum\":4,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MATERIALS SCIENCE, COMPOSITES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Composite Materials","FirstCategoryId":"88","ListUrlMain":"https://link.springer.com/article/10.1007/s10443-024-10234-z","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MATERIALS SCIENCE, COMPOSITES","Score":null,"Total":0}
引用次数: 0

摘要

碳纤维增强热塑性管状结构可在高温下通过旋转拉伸弯曲 (RDB) 后成型为所需的曲率。在这一过程中,需要一个刚性内部芯棒来支撑管壁,以保持其椭圆度,并最大限度地减少不必要的几何变形。本文研究了四种用于后成型碳纤维增强聚酰胺 6 (CF/PA6) 热塑性管材的内部芯棒设计。心轴设计包括硅胶棒、子弹头、金属丝和螺旋弹簧,并通过[± 60°]4 CF/PA6 管的 RDB 成形实验进行了评估。通过测量成型后管材的直径和外径应变,评估了这些设计在最大程度减少成型后诱导应力导致的变形方面的有效性。此外,还对心轴设计在集成到 RDB 工艺中时的可用性进行了评估。光学测量和微计算机断层扫描的结果表明,弹簧心轴的性能优于其他心轴,其生产的管材在成型过程中几何变形最小,且无缺陷。与其他设计相比,弹簧心轴是一种可重复使用的一体式设计,易于组装和拆卸。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Comparison of Internal Mandrel Designs for Rotary Draw Bend Forming of Carbon-fibre/Thermoplastic (PA6) Tubular Structures

Carbon fibre reinforced thermoplastic tubular structures can be post-formed into desired curvatures via rotary draw bending (RDB) at elevated temperatures. During this process, a rigid internal mandrel is required to support the walls of the tubes to maintain their ovality and minimise unwanted geometrical distortions. This paper investigates four internal mandrel designs for post-forming carbon fiber reinforced polyamide 6 (CF/PA6) thermoplastic tubes. Mandrel designs include silicone rod, bullet, wire, and coil spring, were evaluated through RDB-forming experiments with [± 60°]4 CF/PA6 tubes formed to 90° bends. The designs were evaluated for their effectiveness on minimising distortions resulted from induced stresses during post-forming by measuring the post-formed tube diameter and extrados strains. The mandrel designs were also evaluated for their usability when integrated into the RDB process. Results from optical measurements and micro-computed tomography showed the spring mandrel outperformed others, producing tubes with the least geometrical distortions and no defects during the forming process. As compared to other designs, the spring mandrel is a reusable unibody design that is easy to assemble and remove from the tubes.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Applied Composite Materials
Applied Composite Materials 工程技术-材料科学:复合
CiteScore
4.20
自引率
4.30%
发文量
81
审稿时长
1.6 months
期刊介绍: Applied Composite Materials is an international journal dedicated to the publication of original full-length papers, review articles and short communications of the highest quality that advance the development and application of engineering composite materials. Its articles identify problems that limit the performance and reliability of the composite material and composite part; and propose solutions that lead to innovation in design and the successful exploitation and commercialization of composite materials across the widest spectrum of engineering uses. The main focus is on the quantitative descriptions of material systems and processing routes. Coverage includes management of time-dependent changes in microscopic and macroscopic structure and its exploitation from the material''s conception through to its eventual obsolescence.
期刊最新文献
A Coupled Elastoplastic-Damage Analytical Model for 3D Resin-Matrix Woven Composites Effect of Temperature on the Mixed mode I/II Translaminar Fracture of Epoxy Composites Reinforced with Cotton Fibers Experimental Characterisation of Cure-Dependent Spring-Back Behaviour of Metal-Composite Laminates in a Hot-Pressing Process Cutting Force Model of SiCp/Al Composites in Ultrasonic Elliptical Vibration Assisted Cutting with Negative Rake Angle Experimental and Simulation Analysis of the Mechanical Deterioration Mechanisms in SiCp/A356 Composites Under Thermal Cycling Load
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1