{"title":"利用广泛使用的点对点医疗信息交换平台分析两家医疗机构之间的实验室数据传输:案例报告","authors":"Hung S Luu, Walter S Campbell, Raja A Cholan, Mary E. Edgerton, Andrea Englund, Alana Keller, Elizabeth D. Korte, Sandra H Mitchell, Greg T Watkins, Lindsay Westervelt, Daniel Wyman, Stephen Powell","doi":"10.1093/jamiaopen/ooae032","DOIUrl":null,"url":null,"abstract":"Abstract Objective The objective was to identify information loss that could affect clinical care in laboratory data transmission between 2 health care institutions via a Health Information Exchange platform. Materials and Methods Data transmission results of 9 laboratory tests, including LOINC codes, were compared in the following: between sending and receiving electronic health record (EHR) systems, the individual Health Level Seven International (HL7) Version 2 messages across the instrument, laboratory information system, and sending EHR. Results Loss of information for similar tests indicated the following potential patient safety issues: (1) consistently missing specimen source; (2) lack of reporting of analytical technique or instrument platform; (3) inconsistent units and reference ranges; (4) discordant LOINC code use; and (5) increased complexity with multiple HL7 versions. Discussion and Conclusions Using an HIE with standard messaging, SHIELD (Systemic Harmonization and Interoperability Enhancement for Laboratory Data) recommendations, and enhanced EHR functionality to support necessary data elements would yield consistent test identification and result value transmission.","PeriodicalId":36278,"journal":{"name":"JAMIA Open","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2024-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of laboratory data transmission between two healthcare institutions using a widely used point-to-point health information exchange platform: a case report\",\"authors\":\"Hung S Luu, Walter S Campbell, Raja A Cholan, Mary E. Edgerton, Andrea Englund, Alana Keller, Elizabeth D. Korte, Sandra H Mitchell, Greg T Watkins, Lindsay Westervelt, Daniel Wyman, Stephen Powell\",\"doi\":\"10.1093/jamiaopen/ooae032\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Objective The objective was to identify information loss that could affect clinical care in laboratory data transmission between 2 health care institutions via a Health Information Exchange platform. Materials and Methods Data transmission results of 9 laboratory tests, including LOINC codes, were compared in the following: between sending and receiving electronic health record (EHR) systems, the individual Health Level Seven International (HL7) Version 2 messages across the instrument, laboratory information system, and sending EHR. Results Loss of information for similar tests indicated the following potential patient safety issues: (1) consistently missing specimen source; (2) lack of reporting of analytical technique or instrument platform; (3) inconsistent units and reference ranges; (4) discordant LOINC code use; and (5) increased complexity with multiple HL7 versions. Discussion and Conclusions Using an HIE with standard messaging, SHIELD (Systemic Harmonization and Interoperability Enhancement for Laboratory Data) recommendations, and enhanced EHR functionality to support necessary data elements would yield consistent test identification and result value transmission.\",\"PeriodicalId\":36278,\"journal\":{\"name\":\"JAMIA Open\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-04-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JAMIA Open\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1093/jamiaopen/ooae032\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"HEALTH CARE SCIENCES & SERVICES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JAMIA Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jamiaopen/ooae032","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0

摘要

摘要 目的 通过健康信息交换平台在两家医疗机构之间进行实验室数据传输时,找出可能影响临床护理的信息丢失情况。材料与方法 比较了包括 LOINC 代码在内的 9 项实验室检验的数据传输结果:发送和接收电子健康记录(EHR)系统之间的数据传输结果、仪器、实验室信息系统和发送电子健康记录之间的单个健康七级国际(HL7)第 2 版信息。结果 类似检验信息的丢失表明存在以下潜在的患者安全问题:(1) 始终缺少标本来源;(2) 缺少分析技术或仪器平台的报告;(3) 单位和参考范围不一致;(4) LOINC 代码使用不一致;(5) 多个 HL7 版本增加了复杂性。讨论与结论 使用具有标准信息传递功能的 HIE、SHIELD(实验室数据的系统协调与互操作性增强)建议,以及增强的 EHR 功能来支持必要的数据元素,将产生一致的检验标识和结果值传输。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analysis of laboratory data transmission between two healthcare institutions using a widely used point-to-point health information exchange platform: a case report
Abstract Objective The objective was to identify information loss that could affect clinical care in laboratory data transmission between 2 health care institutions via a Health Information Exchange platform. Materials and Methods Data transmission results of 9 laboratory tests, including LOINC codes, were compared in the following: between sending and receiving electronic health record (EHR) systems, the individual Health Level Seven International (HL7) Version 2 messages across the instrument, laboratory information system, and sending EHR. Results Loss of information for similar tests indicated the following potential patient safety issues: (1) consistently missing specimen source; (2) lack of reporting of analytical technique or instrument platform; (3) inconsistent units and reference ranges; (4) discordant LOINC code use; and (5) increased complexity with multiple HL7 versions. Discussion and Conclusions Using an HIE with standard messaging, SHIELD (Systemic Harmonization and Interoperability Enhancement for Laboratory Data) recommendations, and enhanced EHR functionality to support necessary data elements would yield consistent test identification and result value transmission.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
JAMIA Open
JAMIA Open Medicine-Health Informatics
CiteScore
4.10
自引率
4.80%
发文量
102
审稿时长
16 weeks
期刊最新文献
Bridging clinical informatics and implementation science to improve cancer symptom management in ambulatory oncology practices: experiences from the IMPACT consortium. Leveraging a global, federated, real-world data network to optimize investigator-initiated pediatric clinical trials: the TriNetX Pediatric Collaboratory Network. Implementing virtual desktops for clinical research at an academic health center: a case report. Prompt engineering with a large language model to assist providers in responding to patient inquiries: a real-time implementation in the electronic health record. Development and evaluation of an artificial intelligence-based workflow for the prioritization of patient portal messages.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1