使用分析概况指数 (API) 20E KIT 方法验证鉴定嗜水气单胞菌的分析方法

Diah Artati, Moh. Oman, Supriyanto Supriyanto, D. Sukarta, A. Robisalmi
{"title":"使用分析概况指数 (API) 20E KIT 方法验证鉴定嗜水气单胞菌的分析方法","authors":"Diah Artati, Moh. Oman, Supriyanto Supriyanto, D. Sukarta, A. Robisalmi","doi":"10.20473/jmv.vol7.iss1.2024.88-104","DOIUrl":null,"url":null,"abstract":"The high demand for fish consumption has an impact on increasing aquaculture productivity and causes the vulnerability of increasing bacterial populations in aquaculture fields, so more rapid handling is needed. The use of phenotypic KIT methods (API 20E) has been applied as a targeted and efficient identification support in targeting better bacterial identification accuracy but often provides unequal results. Method validation is one of the general requirements for the competence of a laboratory evaluation: to provide coherent, interpretable, and accurate results with known uncertainties. The purpose of this study was to validate the API 20E KIT method for the identification of A. hydrophila. The conventional method used as a reference is SNI 7303.1:2015. The validation parameters consisted of determining the limit of detection, sensitivity, and specificity tests, as well as the positive predictive value and negative predictive value. The results showed that the limit of the detection value of the API 20E KIT was at a concentration of 100 CFU/mL with an ID of 99.00%. The sensitivity and specificity values in the positive and negative target samples were 100% with a positive predictive value and a negative predictive value of 0%, respectively. In conclusion, the API 20E KIT method as an alternative test method or rapid test was proven valid for identifying A. hydrophila by the test results using the reference method.","PeriodicalId":17972,"journal":{"name":"Jurnal Medik Veteriner","volume":"25 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validation of Analytical Method for Aeromonas hydrophila Identification using Analytical Profile Index (API) 20E KIT Method\",\"authors\":\"Diah Artati, Moh. Oman, Supriyanto Supriyanto, D. Sukarta, A. Robisalmi\",\"doi\":\"10.20473/jmv.vol7.iss1.2024.88-104\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The high demand for fish consumption has an impact on increasing aquaculture productivity and causes the vulnerability of increasing bacterial populations in aquaculture fields, so more rapid handling is needed. The use of phenotypic KIT methods (API 20E) has been applied as a targeted and efficient identification support in targeting better bacterial identification accuracy but often provides unequal results. Method validation is one of the general requirements for the competence of a laboratory evaluation: to provide coherent, interpretable, and accurate results with known uncertainties. The purpose of this study was to validate the API 20E KIT method for the identification of A. hydrophila. The conventional method used as a reference is SNI 7303.1:2015. The validation parameters consisted of determining the limit of detection, sensitivity, and specificity tests, as well as the positive predictive value and negative predictive value. The results showed that the limit of the detection value of the API 20E KIT was at a concentration of 100 CFU/mL with an ID of 99.00%. The sensitivity and specificity values in the positive and negative target samples were 100% with a positive predictive value and a negative predictive value of 0%, respectively. In conclusion, the API 20E KIT method as an alternative test method or rapid test was proven valid for identifying A. hydrophila by the test results using the reference method.\",\"PeriodicalId\":17972,\"journal\":{\"name\":\"Jurnal Medik Veteriner\",\"volume\":\"25 3\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Medik Veteriner\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.20473/jmv.vol7.iss1.2024.88-104\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Medik Veteriner","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20473/jmv.vol7.iss1.2024.88-104","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

对水产品消费的高需求影响了水产养殖生产力的提高,并导致水产养殖场中的细菌数量不断增加,因此需要更快速的处理方法。表型 KIT 方法(API 20E)作为一种有针对性的高效鉴定辅助手段,可提高细菌鉴定的准确性,但其结果往往不一致。方法验证是实验室评估能力的一般要求之一:在已知不确定性的情况下提供连贯、可解释和准确的结果。本研究的目的是验证 API 20E KIT 方法对蚜虫水华的鉴定效果。参照的传统方法是 SNI 7303.1:2015。验证参数包括确定检测限、灵敏度和特异性测试,以及阳性预测值和阴性预测值。结果显示,API 20E KIT 的检出限为 100 CFU/mL,ID 值为 99.00%。阳性和阴性目标样本的灵敏度和特异性值均为 100%,阳性预测值和阴性预测值分别为 0%。总之,API 20E KIT 方法作为一种替代检测方法或快速检测方法,通过使用参考方法的检测结果证明了其在鉴定嗜水蝇方面的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Validation of Analytical Method for Aeromonas hydrophila Identification using Analytical Profile Index (API) 20E KIT Method
The high demand for fish consumption has an impact on increasing aquaculture productivity and causes the vulnerability of increasing bacterial populations in aquaculture fields, so more rapid handling is needed. The use of phenotypic KIT methods (API 20E) has been applied as a targeted and efficient identification support in targeting better bacterial identification accuracy but often provides unequal results. Method validation is one of the general requirements for the competence of a laboratory evaluation: to provide coherent, interpretable, and accurate results with known uncertainties. The purpose of this study was to validate the API 20E KIT method for the identification of A. hydrophila. The conventional method used as a reference is SNI 7303.1:2015. The validation parameters consisted of determining the limit of detection, sensitivity, and specificity tests, as well as the positive predictive value and negative predictive value. The results showed that the limit of the detection value of the API 20E KIT was at a concentration of 100 CFU/mL with an ID of 99.00%. The sensitivity and specificity values in the positive and negative target samples were 100% with a positive predictive value and a negative predictive value of 0%, respectively. In conclusion, the API 20E KIT method as an alternative test method or rapid test was proven valid for identifying A. hydrophila by the test results using the reference method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.90
自引率
0.00%
发文量
0
期刊最新文献
Epidermal Growth Factor Promotes E6 and CCL-81 Vero Cells Proliferation Under Serum-Free Condition Microbial Contamination in Chicken Meat in Traditional Markets in Banyuwangi Detection of Foot and Mouth Disease Virus in Salted Raw Cowhide from Malaysia in Tanjung Priok Port, Indonesia Validation of Analytical Method for Aeromonas hydrophila Identification using Analytical Profile Index (API) 20E KIT Method Efficacy of Black Cumin (Nigella sativa) Ameliorate Organophosphate Toxicity in Pregnant Rats Based on Progesterone Levels and Fetal Bone Development
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1