磁共振成像检测肺结节的诊断性能:系统回顾与元分析》。

IF 3.8 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Radiology. Cardiothoracic imaging Pub Date : 2024-04-01 DOI:10.1148/ryct.230241
C. Cavion, S. Altmayer, G. Forte, Rubens Gabriel Feijó Andrade, D. Hochhegger, Martina Zaguini Francisco, Capitulino Camargo, Pratik Patel, Bruno Hochhegger
{"title":"磁共振成像检测肺结节的诊断性能:系统回顾与元分析》。","authors":"C. Cavion, S. Altmayer, G. Forte, Rubens Gabriel Feijó Andrade, D. Hochhegger, Martina Zaguini Francisco, Capitulino Camargo, Pratik Patel, Bruno Hochhegger","doi":"10.1148/ryct.230241","DOIUrl":null,"url":null,"abstract":"Purpose To perform a meta-analysis of the diagnostic performance of MRI for the detection of pulmonary nodules, with use of CT as the reference standard. Materials and Methods PubMed, Embase, Scopus, and other databases were systematically searched for studies published from January 2000 to March 2023 evaluating the performance of MRI for diagnosis of lung nodules measuring 4 mm or larger, with CT as reference. Studies including micronodules, nodules without size stratification, or those from which data for contingency tables could not be extracted were excluded. Primary outcomes were the per-lesion sensitivity of MRI and the rate of false-positive nodules per patient (FPP). Subgroup analysis by size and meta-regression with other covariates were performed. The study protocol was registered in the International Prospective Register of Systematic Reviews, or PROSPERO (no. CRD42023437509). Results Ten studies met inclusion criteria (1354 patients and 2062 CT-detected nodules). Overall, per-lesion sensitivity of MRI for nodules measuring 4 mm or larger was 87.7% (95% CI: 81.1, 92.2), while the FPP rate was 12.4% (95% CI: 7.0, 21.1). Subgroup analyses demonstrated that MRI sensitivity was 98.5% (95% CI: 90.4, 99.8) for nodules measuring at least 8-10 mm and 80.5% (95% CI: 71.5, 87.1) for nodules less than 8 mm. Conclusion MRI demonstrated a good overall performance for detection of pulmonary nodules measuring 4 mm or larger and almost equal performance to CT for nodules measuring at least 8-10 mm, with a low rate of FPP. Systematic review registry no. CRD42023437509 Keywords: Lung Nodule, Lung Cancer, Lung Cancer Screening, MRI, CT Supplemental material is available for this article. © RSNA, 2024.","PeriodicalId":21168,"journal":{"name":"Radiology. Cardiothoracic imaging","volume":null,"pages":null},"PeriodicalIF":3.8000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Diagnostic Performance of MRI for the Detection of Pulmonary Nodules: A Systematic Review and Meta-Analysis.\",\"authors\":\"C. Cavion, S. Altmayer, G. Forte, Rubens Gabriel Feijó Andrade, D. Hochhegger, Martina Zaguini Francisco, Capitulino Camargo, Pratik Patel, Bruno Hochhegger\",\"doi\":\"10.1148/ryct.230241\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose To perform a meta-analysis of the diagnostic performance of MRI for the detection of pulmonary nodules, with use of CT as the reference standard. Materials and Methods PubMed, Embase, Scopus, and other databases were systematically searched for studies published from January 2000 to March 2023 evaluating the performance of MRI for diagnosis of lung nodules measuring 4 mm or larger, with CT as reference. Studies including micronodules, nodules without size stratification, or those from which data for contingency tables could not be extracted were excluded. Primary outcomes were the per-lesion sensitivity of MRI and the rate of false-positive nodules per patient (FPP). Subgroup analysis by size and meta-regression with other covariates were performed. The study protocol was registered in the International Prospective Register of Systematic Reviews, or PROSPERO (no. CRD42023437509). Results Ten studies met inclusion criteria (1354 patients and 2062 CT-detected nodules). Overall, per-lesion sensitivity of MRI for nodules measuring 4 mm or larger was 87.7% (95% CI: 81.1, 92.2), while the FPP rate was 12.4% (95% CI: 7.0, 21.1). Subgroup analyses demonstrated that MRI sensitivity was 98.5% (95% CI: 90.4, 99.8) for nodules measuring at least 8-10 mm and 80.5% (95% CI: 71.5, 87.1) for nodules less than 8 mm. Conclusion MRI demonstrated a good overall performance for detection of pulmonary nodules measuring 4 mm or larger and almost equal performance to CT for nodules measuring at least 8-10 mm, with a low rate of FPP. Systematic review registry no. CRD42023437509 Keywords: Lung Nodule, Lung Cancer, Lung Cancer Screening, MRI, CT Supplemental material is available for this article. © RSNA, 2024.\",\"PeriodicalId\":21168,\"journal\":{\"name\":\"Radiology. Cardiothoracic imaging\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiology. Cardiothoracic imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1148/ryct.230241\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiology. Cardiothoracic imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1148/ryct.230241","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的 对使用 CT 作为参考标准的核磁共振成像检测肺结节的诊断性能进行荟萃分析。材料和方法 系统检索了 PubMed、Embase、Scopus 和其他数据库中 2000 年 1 月至 2023 年 3 月期间发表的、以 CT 为参考标准评估 MRI 诊断 4 毫米或更大肺结节性能的研究。包括微小结节、未进行大小分层的结节或无法提取或然率表数据的研究均被排除在外。主要结果是核磁共振成像对每个结节的敏感性和每位患者的假阳性结节率(FPP)。研究还进行了规模分组分析以及与其他协变量的元回归分析。研究方案已在《国际系统回顾前瞻性注册》(International Prospective Register of Systematic Reviews,简称 PROSPERO,编号 CRD42023437509)中注册。结果 十项研究符合纳入标准(1354 名患者和 2062 个 CT 检测到的结节)。总体而言,MRI 对 4 毫米或更大结节的单病灶敏感性为 87.7%(95% CI:81.1, 92.2),而 FPP 率为 12.4%(95% CI:7.0, 21.1)。亚组分析表明,磁共振成像对至少 8-10 毫米的结节的敏感性为 98.5%(95% CI:90.4,99.8),对小于 8 毫米的结节的敏感性为 80.5%(95% CI:71.5,87.1)。结论 核磁共振成像在检测 4 毫米或更大的肺结节方面表现出良好的整体性能,在检测至少 8-10 毫米的结节方面与 CT 的性能几乎相当,但 FPP 的发生率较低。系统回顾登记号CRD42023437509 关键词: 肺结节肺结节 肺癌 肺癌筛查 核磁共振成像 CT 这篇文章有补充材料。© RSNA, 2024.
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Diagnostic Performance of MRI for the Detection of Pulmonary Nodules: A Systematic Review and Meta-Analysis.
Purpose To perform a meta-analysis of the diagnostic performance of MRI for the detection of pulmonary nodules, with use of CT as the reference standard. Materials and Methods PubMed, Embase, Scopus, and other databases were systematically searched for studies published from January 2000 to March 2023 evaluating the performance of MRI for diagnosis of lung nodules measuring 4 mm or larger, with CT as reference. Studies including micronodules, nodules without size stratification, or those from which data for contingency tables could not be extracted were excluded. Primary outcomes were the per-lesion sensitivity of MRI and the rate of false-positive nodules per patient (FPP). Subgroup analysis by size and meta-regression with other covariates were performed. The study protocol was registered in the International Prospective Register of Systematic Reviews, or PROSPERO (no. CRD42023437509). Results Ten studies met inclusion criteria (1354 patients and 2062 CT-detected nodules). Overall, per-lesion sensitivity of MRI for nodules measuring 4 mm or larger was 87.7% (95% CI: 81.1, 92.2), while the FPP rate was 12.4% (95% CI: 7.0, 21.1). Subgroup analyses demonstrated that MRI sensitivity was 98.5% (95% CI: 90.4, 99.8) for nodules measuring at least 8-10 mm and 80.5% (95% CI: 71.5, 87.1) for nodules less than 8 mm. Conclusion MRI demonstrated a good overall performance for detection of pulmonary nodules measuring 4 mm or larger and almost equal performance to CT for nodules measuring at least 8-10 mm, with a low rate of FPP. Systematic review registry no. CRD42023437509 Keywords: Lung Nodule, Lung Cancer, Lung Cancer Screening, MRI, CT Supplemental material is available for this article. © RSNA, 2024.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
20.40
自引率
1.40%
发文量
0
期刊介绍:
期刊最新文献
Association of Aortic Stiffness with Heart Failure with Preserved Ejection Fraction: New Insights into the Ventriculoarterial Connection. Severe Quadricuspid Pulmonary Valve Stenosis Presenting as Scrotal Edema. Collateral Circulation in Coarctation. Geometric Changes in Mitral Valve Apparatus during Long-term Cardiac Resynchronization Therapy as Assessed with Cardiac CT. Clinically Relevant Extracardiac Findings at Cardiac Imaging: Insights from the European MR/CT Registry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1