开发反转录环介导等温扩增测定法和新型 pH 生物传感器定量读出法,用于检测 SARS-CoV-2

IF 2.2 4区 医学 Q4 IMMUNOLOGY Apmis Pub Date : 2024-04-25 DOI:10.1111/apm.13415
Dian Ekayanti Astari, Muhammad Nasrum Massi, Rina Masadah, Marhaen Hardjo, Rosdiana Natzir, Michael Erlichster, Gursharan Chana, Efstratios Skafidas, Zeba Islam Seraj, Sabrina M. Elias, Gita Vita Soraya
{"title":"开发反转录环介导等温扩增测定法和新型 pH 生物传感器定量读出法,用于检测 SARS-CoV-2","authors":"Dian Ekayanti Astari,&nbsp;Muhammad Nasrum Massi,&nbsp;Rina Masadah,&nbsp;Marhaen Hardjo,&nbsp;Rosdiana Natzir,&nbsp;Michael Erlichster,&nbsp;Gursharan Chana,&nbsp;Efstratios Skafidas,&nbsp;Zeba Islam Seraj,&nbsp;Sabrina M. Elias,&nbsp;Gita Vita Soraya","doi":"10.1111/apm.13415","DOIUrl":null,"url":null,"abstract":"<p>Reverse transcription loop-mediated isothermal amplification (RT-LAMP) is a molecular amplification method that can detect SARS-CoV-2 in a shorter time than the current gold-standard molecular diagnostic reverse transcription-polymerase chain reaction (RT-PCR). However, previously developed RT-LAMP assays have mostly relied on highly subjective visual colorimetric interpretation. In this study, an RT-LAMP assay was developed with quantitative measurement of reaction pH using a novel portable pH biosensor compared to qualitative colorimetric interpretation and gel electrophoresis, with 57 clinical COVID-19 samples used for validation of the test. The LoD of the assay is 10<sup>3</sup> copies/μL. The highest sensitivity was found in the qualitative methods (93.75%), while the highest specificity and likelihood ratio was found in the pH sensor (87.5% and 6.72). On the sensor measurement, a significant difference (p &lt; 0.0001) was observed between the average pH of the RT-PCR (+) COVID-19 (6.15 ± 0.27), while the average pH of the RT-PCR (−) samples (6.72 ± 0.22). Correlation analysis revealed a strong correlation (r = 0.78, p &lt; 0.0001) between the Ct values obtained from RT-PCR with the biosensor pH readout. RT-LAMP with the quantitative pH sensor readout method has the potential to be further developed as an objective molecular assay for rapid and simple detection of SARS-CoV-2.</p>","PeriodicalId":8167,"journal":{"name":"Apmis","volume":"132 7","pages":"499-506"},"PeriodicalIF":2.2000,"publicationDate":"2024-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of a reverse transcription loop-mediated isothermal amplification assay with novel quantitative pH biosensor readout method for SARS-CoV-2 detection\",\"authors\":\"Dian Ekayanti Astari,&nbsp;Muhammad Nasrum Massi,&nbsp;Rina Masadah,&nbsp;Marhaen Hardjo,&nbsp;Rosdiana Natzir,&nbsp;Michael Erlichster,&nbsp;Gursharan Chana,&nbsp;Efstratios Skafidas,&nbsp;Zeba Islam Seraj,&nbsp;Sabrina M. Elias,&nbsp;Gita Vita Soraya\",\"doi\":\"10.1111/apm.13415\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Reverse transcription loop-mediated isothermal amplification (RT-LAMP) is a molecular amplification method that can detect SARS-CoV-2 in a shorter time than the current gold-standard molecular diagnostic reverse transcription-polymerase chain reaction (RT-PCR). However, previously developed RT-LAMP assays have mostly relied on highly subjective visual colorimetric interpretation. In this study, an RT-LAMP assay was developed with quantitative measurement of reaction pH using a novel portable pH biosensor compared to qualitative colorimetric interpretation and gel electrophoresis, with 57 clinical COVID-19 samples used for validation of the test. The LoD of the assay is 10<sup>3</sup> copies/μL. The highest sensitivity was found in the qualitative methods (93.75%), while the highest specificity and likelihood ratio was found in the pH sensor (87.5% and 6.72). On the sensor measurement, a significant difference (p &lt; 0.0001) was observed between the average pH of the RT-PCR (+) COVID-19 (6.15 ± 0.27), while the average pH of the RT-PCR (−) samples (6.72 ± 0.22). Correlation analysis revealed a strong correlation (r = 0.78, p &lt; 0.0001) between the Ct values obtained from RT-PCR with the biosensor pH readout. RT-LAMP with the quantitative pH sensor readout method has the potential to be further developed as an objective molecular assay for rapid and simple detection of SARS-CoV-2.</p>\",\"PeriodicalId\":8167,\"journal\":{\"name\":\"Apmis\",\"volume\":\"132 7\",\"pages\":\"499-506\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-04-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Apmis\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/apm.13415\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"IMMUNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Apmis","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/apm.13415","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"IMMUNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

反转录环介导等温扩增(RT-LAMP)是一种分子扩增方法,与目前的黄金标准分子诊断反转录聚合酶链反应(RT-PCR)相比,它能在更短的时间内检测出 SARS-CoV-2 病毒。然而,以前开发的 RT-LAMP 检测方法大多依赖于非常主观的目测比色法。本研究开发了一种 RT-LAMP 检测方法,使用新型便携式 pH 值生物传感器定量测量反应 pH 值,并与定性比色判读和凝胶电泳进行比较。该检测方法的 LoD 为 103 个拷贝/μL。定性方法的灵敏度最高(93.75%),而 pH 传感器的特异性和似然比最高(87.5% 和 6.72)。在传感器测量方面,RT-PCR (+) COVID-19 的平均 pH 值(6.15 ± 0.27)与 RT-PCR (-) 样品的平均 pH 值(6.72 ± 0.22)之间存在显著差异(p < 0.0001)。相关分析表明,RT-PCR 获得的 Ct 值与生物传感器 pH 读数之间存在很强的相关性(r = 0.78,p < 0.0001)。RT-LAMP与定量pH传感器读数法有可能进一步发展成为一种客观的分子检测方法,用于快速、简单地检测SARS-CoV-2。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Development of a reverse transcription loop-mediated isothermal amplification assay with novel quantitative pH biosensor readout method for SARS-CoV-2 detection

Reverse transcription loop-mediated isothermal amplification (RT-LAMP) is a molecular amplification method that can detect SARS-CoV-2 in a shorter time than the current gold-standard molecular diagnostic reverse transcription-polymerase chain reaction (RT-PCR). However, previously developed RT-LAMP assays have mostly relied on highly subjective visual colorimetric interpretation. In this study, an RT-LAMP assay was developed with quantitative measurement of reaction pH using a novel portable pH biosensor compared to qualitative colorimetric interpretation and gel electrophoresis, with 57 clinical COVID-19 samples used for validation of the test. The LoD of the assay is 103 copies/μL. The highest sensitivity was found in the qualitative methods (93.75%), while the highest specificity and likelihood ratio was found in the pH sensor (87.5% and 6.72). On the sensor measurement, a significant difference (p < 0.0001) was observed between the average pH of the RT-PCR (+) COVID-19 (6.15 ± 0.27), while the average pH of the RT-PCR (−) samples (6.72 ± 0.22). Correlation analysis revealed a strong correlation (r = 0.78, p < 0.0001) between the Ct values obtained from RT-PCR with the biosensor pH readout. RT-LAMP with the quantitative pH sensor readout method has the potential to be further developed as an objective molecular assay for rapid and simple detection of SARS-CoV-2.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Apmis
Apmis 医学-病理学
CiteScore
5.20
自引率
0.00%
发文量
91
审稿时长
2 months
期刊介绍: APMIS, formerly Acta Pathologica, Microbiologica et Immunologica Scandinavica, has been published since 1924 by the Scandinavian Societies for Medical Microbiology and Pathology as a non-profit-making scientific journal.
期刊最新文献
Single cells and bacterial biofilm populations in chronic wound infections. Vaginal microecology and its role in human papillomavirus infection and human papillomavirus associated cervical lesions. Metabolic drives affecting Th17/Treg gene expression changes and differentiation: impact on immune-microenvironment regulation. Bacterial aerobic respiration is a major consumer of oxygen in sputum from patients with acute lower respiratory tract infection. Unraveling the intricacies of cancer-associated fibroblasts: a comprehensive review on metabolic reprogramming and tumor microenvironment crosstalk.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1