本质性高血压患者血浆中 Sirtuin 7 的水平降低

IF 2.5 3区 医学 Q2 MEDICAL LABORATORY TECHNOLOGY Clinical biochemistry Pub Date : 2024-04-26 DOI:10.1016/j.clinbiochem.2024.110766
Ying Liu , Ying Guo , Ning Wang , Zhaojie Dong , Xiaoyan Yang , Qian Liu , Guohong Wang , Mingzhao Qin , Jiawei Song , Jing Li , Li Xu , Ying Dong , Jiuchang Zhong
{"title":"本质性高血压患者血浆中 Sirtuin 7 的水平降低","authors":"Ying Liu ,&nbsp;Ying Guo ,&nbsp;Ning Wang ,&nbsp;Zhaojie Dong ,&nbsp;Xiaoyan Yang ,&nbsp;Qian Liu ,&nbsp;Guohong Wang ,&nbsp;Mingzhao Qin ,&nbsp;Jiawei Song ,&nbsp;Jing Li ,&nbsp;Li Xu ,&nbsp;Ying Dong ,&nbsp;Jiuchang Zhong","doi":"10.1016/j.clinbiochem.2024.110766","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Sirtuin 7 (SIRT7), as a nicotinamide adenine dinucleotide-dependent protein/histone deacetylase, has been implicated in the pathogenesis of cardiovascular diseases. However, whether SIRT7 is related to hypertension remains largely unclear. Thus, this study aims to explore the effects and correlation between SIRT7 and hypertension.</p></div><div><h3>Methods</h3><p>A total of 72 patients with essential hypertension and 82 controls with non-hypertension were recruited at Beijing Tongren Hospital Affiliated with Capital Medical University from July 2022 to June 2023. Plasma SIRT7 expression was measured using enzyme-linked immunosorbent assay analysis. Clinical baseline characteristics, laboratory measurements, echocardiographic data, and medical therapy were collected.</p></div><div><h3>Results</h3><p>Plasma levels of SIRT7 were lower in hypertensive patients compared with non-hypertensive patients [0.97 (0.58–1.30) vs. 1.24 (0.99–1.46) ng/mL, <em>P</em> &lt; 0.001, respectively]. Furthermore, compared with the low SIRT7 group, there were lower levels of systolic blood pressure, hyperlipidemia, and the ultrasonic electrocardiogram parameters left ventricular end-diastolic diameter and left atrial in diastole in the high SIRT7 group (<em>P</em> &lt; 0.05, respectively). More importantly, multivariate logistic regression analyses indicated that plasma SIRT7 was a predictor of hypertension [OR: 0.06, 95 % CI (0.02–0.19), <em>P</em> &lt; 0.001]. Receiver operating characteristics curve analysis revealed that the optimal cutoff value for plasma SIRT7 levels in detecting hypertension was determined as 0.85 ng/mL with a sensitivity of 73.6 % and a specificity of 89.0 %. The area under the curve for SIRT7 was 0.821 (95 % CI, 0.751–0.878; <em>P</em> &lt; 0.001).</p></div><div><h3>Conclusion</h3><p>Plasma levels of SIRT7 are decreased in patients with essential hypertension, implying its potential as a biomarker for diagnosing essential hypertension..</p></div>","PeriodicalId":10172,"journal":{"name":"Clinical biochemistry","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2024-04-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Plasma levels of Sirtuin 7 are decreased in patients with essential hypertension\",\"authors\":\"Ying Liu ,&nbsp;Ying Guo ,&nbsp;Ning Wang ,&nbsp;Zhaojie Dong ,&nbsp;Xiaoyan Yang ,&nbsp;Qian Liu ,&nbsp;Guohong Wang ,&nbsp;Mingzhao Qin ,&nbsp;Jiawei Song ,&nbsp;Jing Li ,&nbsp;Li Xu ,&nbsp;Ying Dong ,&nbsp;Jiuchang Zhong\",\"doi\":\"10.1016/j.clinbiochem.2024.110766\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Sirtuin 7 (SIRT7), as a nicotinamide adenine dinucleotide-dependent protein/histone deacetylase, has been implicated in the pathogenesis of cardiovascular diseases. However, whether SIRT7 is related to hypertension remains largely unclear. Thus, this study aims to explore the effects and correlation between SIRT7 and hypertension.</p></div><div><h3>Methods</h3><p>A total of 72 patients with essential hypertension and 82 controls with non-hypertension were recruited at Beijing Tongren Hospital Affiliated with Capital Medical University from July 2022 to June 2023. Plasma SIRT7 expression was measured using enzyme-linked immunosorbent assay analysis. Clinical baseline characteristics, laboratory measurements, echocardiographic data, and medical therapy were collected.</p></div><div><h3>Results</h3><p>Plasma levels of SIRT7 were lower in hypertensive patients compared with non-hypertensive patients [0.97 (0.58–1.30) vs. 1.24 (0.99–1.46) ng/mL, <em>P</em> &lt; 0.001, respectively]. Furthermore, compared with the low SIRT7 group, there were lower levels of systolic blood pressure, hyperlipidemia, and the ultrasonic electrocardiogram parameters left ventricular end-diastolic diameter and left atrial in diastole in the high SIRT7 group (<em>P</em> &lt; 0.05, respectively). More importantly, multivariate logistic regression analyses indicated that plasma SIRT7 was a predictor of hypertension [OR: 0.06, 95 % CI (0.02–0.19), <em>P</em> &lt; 0.001]. Receiver operating characteristics curve analysis revealed that the optimal cutoff value for plasma SIRT7 levels in detecting hypertension was determined as 0.85 ng/mL with a sensitivity of 73.6 % and a specificity of 89.0 %. The area under the curve for SIRT7 was 0.821 (95 % CI, 0.751–0.878; <em>P</em> &lt; 0.001).</p></div><div><h3>Conclusion</h3><p>Plasma levels of SIRT7 are decreased in patients with essential hypertension, implying its potential as a biomarker for diagnosing essential hypertension..</p></div>\",\"PeriodicalId\":10172,\"journal\":{\"name\":\"Clinical biochemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-04-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical biochemistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0009912024000602\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical biochemistry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0009912024000602","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景Sirtuin 7(SIRT7)是一种烟酰胺腺嘌呤二核苷酸依赖性蛋白/组蛋白去乙酰化酶,与心血管疾病的发病机制有关。然而,SIRT7 是否与高血压有关在很大程度上仍不清楚。方法2022年7月至2023年6月,首都医科大学附属北京同仁医院共招募72例本质性高血压患者和82例非高血压对照组。采用酶联免疫吸附分析法检测血浆 SIRT7 的表达。结果与非高血压患者相比,高血压患者的血浆 SIRT7 水平较低 [分别为 0.97 (0.58-1.30) vs. 1.24 (0.99-1.46) ng/mL,P < 0.001]。此外,与低SIRT7组相比,高SIRT7组的收缩压、高脂血症以及超声心电图参数左心室舒张末期直径和左心房舒张期的水平均较低(P分别为0.05)。更重要的是,多变量逻辑回归分析表明,血浆 SIRT7 是高血压的预测因子 [OR: 0.06, 95 % CI (0.02-0.19), P < 0.001]。接收者操作特性曲线分析表明,血浆 SIRT7 水平检测高血压的最佳临界值为 0.85 纳克/毫升,灵敏度为 73.6%,特异度为 89.0%。SIRT7 的曲线下面积为 0.821 (95 % CI, 0.751-0.878; P < 0.001)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Plasma levels of Sirtuin 7 are decreased in patients with essential hypertension

Background

Sirtuin 7 (SIRT7), as a nicotinamide adenine dinucleotide-dependent protein/histone deacetylase, has been implicated in the pathogenesis of cardiovascular diseases. However, whether SIRT7 is related to hypertension remains largely unclear. Thus, this study aims to explore the effects and correlation between SIRT7 and hypertension.

Methods

A total of 72 patients with essential hypertension and 82 controls with non-hypertension were recruited at Beijing Tongren Hospital Affiliated with Capital Medical University from July 2022 to June 2023. Plasma SIRT7 expression was measured using enzyme-linked immunosorbent assay analysis. Clinical baseline characteristics, laboratory measurements, echocardiographic data, and medical therapy were collected.

Results

Plasma levels of SIRT7 were lower in hypertensive patients compared with non-hypertensive patients [0.97 (0.58–1.30) vs. 1.24 (0.99–1.46) ng/mL, P < 0.001, respectively]. Furthermore, compared with the low SIRT7 group, there were lower levels of systolic blood pressure, hyperlipidemia, and the ultrasonic electrocardiogram parameters left ventricular end-diastolic diameter and left atrial in diastole in the high SIRT7 group (P < 0.05, respectively). More importantly, multivariate logistic regression analyses indicated that plasma SIRT7 was a predictor of hypertension [OR: 0.06, 95 % CI (0.02–0.19), P < 0.001]. Receiver operating characteristics curve analysis revealed that the optimal cutoff value for plasma SIRT7 levels in detecting hypertension was determined as 0.85 ng/mL with a sensitivity of 73.6 % and a specificity of 89.0 %. The area under the curve for SIRT7 was 0.821 (95 % CI, 0.751–0.878; P < 0.001).

Conclusion

Plasma levels of SIRT7 are decreased in patients with essential hypertension, implying its potential as a biomarker for diagnosing essential hypertension..

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinical biochemistry
Clinical biochemistry 医学-医学实验技术
CiteScore
5.10
自引率
0.00%
发文量
151
审稿时长
25 days
期刊介绍: Clinical Biochemistry publishes articles relating to clinical chemistry, molecular biology and genetics, therapeutic drug monitoring and toxicology, laboratory immunology and laboratory medicine in general, with the focus on analytical and clinical investigation of laboratory tests in humans used for diagnosis, prognosis, treatment and therapy, and monitoring of disease.
期刊最新文献
Challenges and Perspectives on the Adoption of Cystatin C testing in China: A laboratory technician’s perspective Quantitative evaluation of adalimumab and anti-adalimumab antibodies in sera using a surface plasmon resonance biosensor Inflammation and lipoperoxidation in mucopolysaccharidoses type II patients at diagnosis and post-hematopoietic stem cell transplantation. Multidisciplinary approach to redefining thyroid hormone reference intervals with big data analysis Relationship between analytical imprecision and coefficient of determination (R2) of the calibration curve
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1