比较不同供暖系统的热舒适度和对冬季不同室内气候的适应性

IF 3 3区 地球科学 Q2 BIOPHYSICS International Journal of Biometeorology Pub Date : 2024-04-29 DOI:10.1007/s00484-024-02689-3
Lianfei Zhuang, Jingxin Huang, Fengjuan Li, Ke Zhong
{"title":"比较不同供暖系统的热舒适度和对冬季不同室内气候的适应性","authors":"Lianfei Zhuang, Jingxin Huang, Fengjuan Li, Ke Zhong","doi":"10.1007/s00484-024-02689-3","DOIUrl":null,"url":null,"abstract":"<p>Individual heating systems, such as the air-source heat pump (ASHP) air-conditioner or floor heating (FH), are usually used by people living in the hot summer and cold winter (HSCW) zone of China to heat indoor climates in the winter. However, little research has been conducted in the HSCW zone on the thermal comfort difference between indoor climates heated by ASHP air-conditioners and those heated by floor heating, as well as how occupants adapt to different indoor climates. We conducted a comparative field experiment in ASHP-heated and FH-heated apartments in Nanjing to investigate how different types of heating systems influence the thermal sensation of occupants, and we conducted a comparative field experiment in ASHP-heated office buildings and naturally ventilated teaching buildings in Shanghai to investigate how occupants adapt to different indoor thermal environments. Indoor environmental parameters and body surface temperatures were measured using instruments, and occupants’ thermal sensation, activity level, and clothing were evaluated using the questionnaire. The results show that floor heating improves thermal comfort by raising foot temperature compared to the ASHP air-conditioner, and that occupants become acclimatized to different indoor climates by adjusting neutral operative temperature. According to the findings, there is no need to overheat the indoor environment in the HSCW zone because occupants can adapt to their experienced thermal environment and it is critical to maintain warm foot temperature in the cool/cold indoor environment.</p>","PeriodicalId":588,"journal":{"name":"International Journal of Biometeorology","volume":null,"pages":null},"PeriodicalIF":3.0000,"publicationDate":"2024-04-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of thermal comfort between different heating systems and adaptation to different indoor climates in winter\",\"authors\":\"Lianfei Zhuang, Jingxin Huang, Fengjuan Li, Ke Zhong\",\"doi\":\"10.1007/s00484-024-02689-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Individual heating systems, such as the air-source heat pump (ASHP) air-conditioner or floor heating (FH), are usually used by people living in the hot summer and cold winter (HSCW) zone of China to heat indoor climates in the winter. However, little research has been conducted in the HSCW zone on the thermal comfort difference between indoor climates heated by ASHP air-conditioners and those heated by floor heating, as well as how occupants adapt to different indoor climates. We conducted a comparative field experiment in ASHP-heated and FH-heated apartments in Nanjing to investigate how different types of heating systems influence the thermal sensation of occupants, and we conducted a comparative field experiment in ASHP-heated office buildings and naturally ventilated teaching buildings in Shanghai to investigate how occupants adapt to different indoor thermal environments. Indoor environmental parameters and body surface temperatures were measured using instruments, and occupants’ thermal sensation, activity level, and clothing were evaluated using the questionnaire. The results show that floor heating improves thermal comfort by raising foot temperature compared to the ASHP air-conditioner, and that occupants become acclimatized to different indoor climates by adjusting neutral operative temperature. According to the findings, there is no need to overheat the indoor environment in the HSCW zone because occupants can adapt to their experienced thermal environment and it is critical to maintain warm foot temperature in the cool/cold indoor environment.</p>\",\"PeriodicalId\":588,\"journal\":{\"name\":\"International Journal of Biometeorology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-04-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Biometeorology\",\"FirstCategoryId\":\"89\",\"ListUrlMain\":\"https://doi.org/10.1007/s00484-024-02689-3\",\"RegionNum\":3,\"RegionCategory\":\"地球科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Biometeorology","FirstCategoryId":"89","ListUrlMain":"https://doi.org/10.1007/s00484-024-02689-3","RegionNum":3,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

摘要

中国夏热冬冷(HSCW)区居民通常使用空气源热泵(ASHP)空调或地板采暖(FH)等独立供暖系统在冬季为室内环境供暖。然而,在夏热冬冷地区,关于 ASHP 空调采暖与地暖采暖室内气候的热舒适性差异,以及居住者如何适应不同室内气候的研究还很少。我们在南京进行了 ASHP 供暖公寓和 FH 供暖公寓的现场对比实验,以研究不同类型的供暖系统如何影响居住者的热感觉;我们在上海进行了 ASHP 供暖办公楼和自然通风教学楼的现场对比实验,以研究居住者如何适应不同的室内热环境。实验中使用仪器测量了室内环境参数和体表温度,并通过问卷调查对居住者的热感觉、活动水平和衣着进行了评估。结果表明,与 ASHP 空调相比,地暖通过提高脚部温度来改善热舒适度,而居住者则通过调节中性工作温度来适应不同的室内气候。研究结果表明,由于居住者能够适应其所经历的热环境,因此在 HSCW 区域没有必要使室内环境过热,而在冷/凉室内环境中保持温暖的脚部温度至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of thermal comfort between different heating systems and adaptation to different indoor climates in winter

Individual heating systems, such as the air-source heat pump (ASHP) air-conditioner or floor heating (FH), are usually used by people living in the hot summer and cold winter (HSCW) zone of China to heat indoor climates in the winter. However, little research has been conducted in the HSCW zone on the thermal comfort difference between indoor climates heated by ASHP air-conditioners and those heated by floor heating, as well as how occupants adapt to different indoor climates. We conducted a comparative field experiment in ASHP-heated and FH-heated apartments in Nanjing to investigate how different types of heating systems influence the thermal sensation of occupants, and we conducted a comparative field experiment in ASHP-heated office buildings and naturally ventilated teaching buildings in Shanghai to investigate how occupants adapt to different indoor thermal environments. Indoor environmental parameters and body surface temperatures were measured using instruments, and occupants’ thermal sensation, activity level, and clothing were evaluated using the questionnaire. The results show that floor heating improves thermal comfort by raising foot temperature compared to the ASHP air-conditioner, and that occupants become acclimatized to different indoor climates by adjusting neutral operative temperature. According to the findings, there is no need to overheat the indoor environment in the HSCW zone because occupants can adapt to their experienced thermal environment and it is critical to maintain warm foot temperature in the cool/cold indoor environment.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.40
自引率
9.40%
发文量
183
审稿时长
1 months
期刊介绍: The Journal publishes original research papers, review articles and short communications on studies examining the interactions between living organisms and factors of the natural and artificial atmospheric environment. Living organisms extend from single cell organisms, to plants and animals, including humans. The atmospheric environment includes climate and weather, electromagnetic radiation, and chemical and biological pollutants. The journal embraces basic and applied research and practical aspects such as living conditions, agriculture, forestry, and health. The journal is published for the International Society of Biometeorology, and most membership categories include a subscription to the Journal.
期刊最新文献
The impact of weather anomalies on violence in the coastal mid-latitudes: a cross-national comparison. Exploring the comprehensive link between climatic factors and vegetation productivity in China. Variations, trends and forecast models for the airborne Olea europaea pollen season in Tétouan (NW of Morocco). Clothing and Outdoor Thermal Comfort (OTC) in tourist environments: a case study from Porto (Portugal). Effect of Temperature and Precipitation on Acute Appendicitis Incidence in Seoul: A Time Series Regression Analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1