低剂量与标准剂量儿童正常颞骨 CT 的比较研究

IF 0.7 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Egyptian Journal of Radiology and Nuclear Medicine Pub Date : 2024-04-30 DOI:10.1186/s43055-024-01254-7
R. Rashma, Jyoti Kumar, Anju Garg, Radhika Batra, Ravi Meher, Ankita Phulia
{"title":"低剂量与标准剂量儿童正常颞骨 CT 的比较研究","authors":"R. Rashma, Jyoti Kumar, Anju Garg, Radhika Batra, Ravi Meher, Ankita Phulia","doi":"10.1186/s43055-024-01254-7","DOIUrl":null,"url":null,"abstract":"To compare the image quality of normal anatomical structures and radiation dose on low-dose (LDCT) and standard-dose (SDCT) temporal bone CT in children. The study included 45 LDCT (80 kV and 130 mAs) and 45 SDCT (120 kV and 170 mAs) scans in children, 1–15 years of age. LDCT and SDCT scans were analyzed on H60s and H70h reconstruction kernels, respectively. Two readers assessed the image quality for 25 anatomical structures, using a 5-point scale. A score of 3 and above was considered “sufficient” and 2 and below was considered “insufficient” image quality. Image noise, contrast, age and size-specific effective doses were calculated. Despite an increase in image noise on LDCT, image quality remained sufficient for most structures owing to increased image contrast. The median effective dose on LDCT, calculated with age-specific conversion factor, decreased by 72.9% and that calculated with size-specific conversion factor decreased by 81.8% compared to the dose on SDCT. LDCT provides comparable image quality for evaluation of temporal bone with significant reduction in radiation dose in children.","PeriodicalId":11540,"journal":{"name":"Egyptian Journal of Radiology and Nuclear Medicine","volume":"38 1","pages":""},"PeriodicalIF":0.7000,"publicationDate":"2024-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Low-dose versus standard-dose normal temporal bone CT in children: a comparison study\",\"authors\":\"R. Rashma, Jyoti Kumar, Anju Garg, Radhika Batra, Ravi Meher, Ankita Phulia\",\"doi\":\"10.1186/s43055-024-01254-7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To compare the image quality of normal anatomical structures and radiation dose on low-dose (LDCT) and standard-dose (SDCT) temporal bone CT in children. The study included 45 LDCT (80 kV and 130 mAs) and 45 SDCT (120 kV and 170 mAs) scans in children, 1–15 years of age. LDCT and SDCT scans were analyzed on H60s and H70h reconstruction kernels, respectively. Two readers assessed the image quality for 25 anatomical structures, using a 5-point scale. A score of 3 and above was considered “sufficient” and 2 and below was considered “insufficient” image quality. Image noise, contrast, age and size-specific effective doses were calculated. Despite an increase in image noise on LDCT, image quality remained sufficient for most structures owing to increased image contrast. The median effective dose on LDCT, calculated with age-specific conversion factor, decreased by 72.9% and that calculated with size-specific conversion factor decreased by 81.8% compared to the dose on SDCT. LDCT provides comparable image quality for evaluation of temporal bone with significant reduction in radiation dose in children.\",\"PeriodicalId\":11540,\"journal\":{\"name\":\"Egyptian Journal of Radiology and Nuclear Medicine\",\"volume\":\"38 1\",\"pages\":\"\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2024-04-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Egyptian Journal of Radiology and Nuclear Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s43055-024-01254-7\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Egyptian Journal of Radiology and Nuclear Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s43055-024-01254-7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

比较低剂量(LDCT)和标准剂量(SDCT)儿童颞骨 CT 正常解剖结构的图像质量和辐射剂量。研究包括对 1-15 岁儿童进行的 45 次 LDCT(80 kV 和 130 mAs)和 45 次 SDCT(120 kV 和 170 mAs)扫描。LDCT 和 SDCT 扫描分别在 H60s 和 H70h 重建内核上进行分析。两名阅读者采用 5 级评分法对 25 个解剖结构的图像质量进行评估。3 分及以上为 "足够",2 分及以下为 "不足"。计算了图像噪音、对比度、年龄和体型的有效剂量。尽管 LDCT 的图像噪声有所增加,但由于图像对比度提高,大多数结构的图像质量仍然足够。与 SDCT 的剂量相比,采用年龄特定换算系数计算的 LDCT 有效剂量中位数减少了 72.9%,采用体型特定换算系数计算的有效剂量中位数减少了 81.8%。LDCT 可为儿童颞骨评估提供相当的图像质量,同时显著降低辐射剂量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Low-dose versus standard-dose normal temporal bone CT in children: a comparison study
To compare the image quality of normal anatomical structures and radiation dose on low-dose (LDCT) and standard-dose (SDCT) temporal bone CT in children. The study included 45 LDCT (80 kV and 130 mAs) and 45 SDCT (120 kV and 170 mAs) scans in children, 1–15 years of age. LDCT and SDCT scans were analyzed on H60s and H70h reconstruction kernels, respectively. Two readers assessed the image quality for 25 anatomical structures, using a 5-point scale. A score of 3 and above was considered “sufficient” and 2 and below was considered “insufficient” image quality. Image noise, contrast, age and size-specific effective doses were calculated. Despite an increase in image noise on LDCT, image quality remained sufficient for most structures owing to increased image contrast. The median effective dose on LDCT, calculated with age-specific conversion factor, decreased by 72.9% and that calculated with size-specific conversion factor decreased by 81.8% compared to the dose on SDCT. LDCT provides comparable image quality for evaluation of temporal bone with significant reduction in radiation dose in children.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Egyptian Journal of Radiology and Nuclear Medicine
Egyptian Journal of Radiology and Nuclear Medicine Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
1.70
自引率
10.00%
发文量
233
审稿时长
27 weeks
期刊最新文献
Fetal hemochromatosis: rare case of hepatic and extrahepatic siderosis involving thyroid on fetal MRI Ultrasound-guided combined intra-articular corticosteroids injection and suprascapular nerve block for pain control in patients with frozen shoulder Pharmacomechanical thrombectomy in management of pulmonary embolism Role of intravoxel incoherent motion diffusion-weighted MRI in differentiation of renal cell carcinoma subtypes Explainability, transparency and black box challenges of AI in radiology: impact on patient care in cardiovascular radiology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1