{"title":"McCoy、Macintosh 和 Truview 喉镜在呼吸辅助鼻气管插管方面的比较:随机对照研究。","authors":"Neha Singh, Chitta Ranjan Mohanty, Sangeeta Sahoo, Manisha Mund, Roncall Bhim Raju","doi":"10.4103/ijciis.ijciis_49_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Video laryngoscopes are commonly used along with Macintosh and McCoy laryngoscopes for Nasotracheal intubation (NTI). The purpose of this study was to evaluate the performance of McCoy, Macintosh, and Truview laryngoscopes during bougie-aided NTI with respect to intubation time, success rate, and hemodynamic changes during the procedure.</p><p><strong>Methods: </strong>Forty-five American Society of Anesthesiologists (ASA) I-II adult patients, with Mallampati grade 1-4, requiring NTI, were enrolled after taking written informed consent. ASA III/IV, restricted mouth opening, and body mass index >30 were excluded from the study. Patients were randomly allocated to intubate with one of the three laryngoscopes (McCoy, Macintosh, and Truview) and the anesthesiologists were well experienced with all of them. The primary outcome was intubation time and secondary outcomes included first attempt success rate, external laryngeal manipulation, Cormack-Lehane (CL) grade, and hemodynamic responses.</p><p><strong>Results: </strong>The intubation time of McCoy, Macintosh, and Truview, was 86.87 ± 15.92, 82.87 ± 16.46, and 79.93 ± 14.53 (mean ± standard deviation) seconds, respectively, which is comparable with Truview being the shortest. CL grade 1 was obtained more in the Truview group (53.3%) compared to the other two groups, while CL grade 3 was obtained in 20% each in McCoy and Macintosh groups.</p><p><strong>Conclusions: </strong>McCoy, Macintosh, and Truview laryngoscopes were comparable in performance during bougie-aided NTI, with Truview having the shortest intubation time and better visualization.</p>","PeriodicalId":13938,"journal":{"name":"International Journal of Critical Illness and Injury Science","volume":"14 1","pages":"3-8"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11073636/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparison of McCoy, Macintosh, and Truview laryngoscope for bougie-aided naso-tracheal intubation: A randomized controlled study.\",\"authors\":\"Neha Singh, Chitta Ranjan Mohanty, Sangeeta Sahoo, Manisha Mund, Roncall Bhim Raju\",\"doi\":\"10.4103/ijciis.ijciis_49_23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Video laryngoscopes are commonly used along with Macintosh and McCoy laryngoscopes for Nasotracheal intubation (NTI). The purpose of this study was to evaluate the performance of McCoy, Macintosh, and Truview laryngoscopes during bougie-aided NTI with respect to intubation time, success rate, and hemodynamic changes during the procedure.</p><p><strong>Methods: </strong>Forty-five American Society of Anesthesiologists (ASA) I-II adult patients, with Mallampati grade 1-4, requiring NTI, were enrolled after taking written informed consent. ASA III/IV, restricted mouth opening, and body mass index >30 were excluded from the study. Patients were randomly allocated to intubate with one of the three laryngoscopes (McCoy, Macintosh, and Truview) and the anesthesiologists were well experienced with all of them. The primary outcome was intubation time and secondary outcomes included first attempt success rate, external laryngeal manipulation, Cormack-Lehane (CL) grade, and hemodynamic responses.</p><p><strong>Results: </strong>The intubation time of McCoy, Macintosh, and Truview, was 86.87 ± 15.92, 82.87 ± 16.46, and 79.93 ± 14.53 (mean ± standard deviation) seconds, respectively, which is comparable with Truview being the shortest. CL grade 1 was obtained more in the Truview group (53.3%) compared to the other two groups, while CL grade 3 was obtained in 20% each in McCoy and Macintosh groups.</p><p><strong>Conclusions: </strong>McCoy, Macintosh, and Truview laryngoscopes were comparable in performance during bougie-aided NTI, with Truview having the shortest intubation time and better visualization.</p>\",\"PeriodicalId\":13938,\"journal\":{\"name\":\"International Journal of Critical Illness and Injury Science\",\"volume\":\"14 1\",\"pages\":\"3-8\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11073636/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Critical Illness and Injury Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/ijciis.ijciis_49_23\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/27 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Critical Illness and Injury Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ijciis.ijciis_49_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/27 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
Comparison of McCoy, Macintosh, and Truview laryngoscope for bougie-aided naso-tracheal intubation: A randomized controlled study.
Background: Video laryngoscopes are commonly used along with Macintosh and McCoy laryngoscopes for Nasotracheal intubation (NTI). The purpose of this study was to evaluate the performance of McCoy, Macintosh, and Truview laryngoscopes during bougie-aided NTI with respect to intubation time, success rate, and hemodynamic changes during the procedure.
Methods: Forty-five American Society of Anesthesiologists (ASA) I-II adult patients, with Mallampati grade 1-4, requiring NTI, were enrolled after taking written informed consent. ASA III/IV, restricted mouth opening, and body mass index >30 were excluded from the study. Patients were randomly allocated to intubate with one of the three laryngoscopes (McCoy, Macintosh, and Truview) and the anesthesiologists were well experienced with all of them. The primary outcome was intubation time and secondary outcomes included first attempt success rate, external laryngeal manipulation, Cormack-Lehane (CL) grade, and hemodynamic responses.
Results: The intubation time of McCoy, Macintosh, and Truview, was 86.87 ± 15.92, 82.87 ± 16.46, and 79.93 ± 14.53 (mean ± standard deviation) seconds, respectively, which is comparable with Truview being the shortest. CL grade 1 was obtained more in the Truview group (53.3%) compared to the other two groups, while CL grade 3 was obtained in 20% each in McCoy and Macintosh groups.
Conclusions: McCoy, Macintosh, and Truview laryngoscopes were comparable in performance during bougie-aided NTI, with Truview having the shortest intubation time and better visualization.
期刊介绍:
IJCIIS encourages research, education and dissemination of knowledge in the field of Critical Illness and Injury Science across the world thus promoting translational research by striking a synergy between basic science, clinical medicine and public health. The Journal intends to bring together scientists and academicians in the emergency intensive care and promote translational synergy between Laboratory Science, Clinical Medicine and Public Health. The Journal invites Original Articles, Clinical Investigations, Epidemiological Analysis, Data Protocols, Case Reports, Clinical Photographs, review articles and special commentaries. Students, Residents, Academicians, Public Health experts and scientists are all encouraged to be a part of this initiative by contributing, reviewing and promoting scientific works and science.