腰腹腔分流手术中使用可调节瓣膜植入脊柱旁肌肉时的脊柱磁共振成像伪影。

IF 0.7 Q4 MEDICINE, RESEARCH & EXPERIMENTAL JOURNAL OF MEDICAL INVESTIGATION Pub Date : 2024-01-01 DOI:10.2152/jmi.71.154
Tatsuya Tanaka, Ryohei Sashida, Yu Hirokawa, Tomihiro Wakamiya, Yuhei Michiwaki, Kazuaki Shimoji, Eiichi Suehiro, Keisuke Onoda, Fumitaka Yamane, Akira Matsuno, Tadatsugu Morimoto
{"title":"腰腹腔分流手术中使用可调节瓣膜植入脊柱旁肌肉时的脊柱磁共振成像伪影。","authors":"Tatsuya Tanaka, Ryohei Sashida, Yu Hirokawa, Tomihiro Wakamiya, Yuhei Michiwaki, Kazuaki Shimoji, Eiichi Suehiro, Keisuke Onoda, Fumitaka Yamane, Akira Matsuno, Tadatsugu Morimoto","doi":"10.2152/jmi.71.154","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Adjustable shunt valves that have been developed for managing hydrocephalus rely on intrinsically magnetic components ; thus, artifacts with these valves on magnetic resonance imaging (MRI) are inevitable. No studies on valve-induced artifacts in lumboperitoneal shunt (LPS) surgery have been published. Therefore, this study aimed to evaluate valve-induced artifacts in LPS.</p><p><strong>Methods: </strong>We retrospectively reviewed all MRIs obtained between January 2023 and June 2023 in patients with an implanted Codman CERTAS Plus adjustable shunt valve (Integra Life Sciences, Princeton, New Jersey, USA). The valve was placed <1 cm subcutaneously on the paravertebral spinal muscle of the back, with its long axis perpendicular to the body axis. The scans were performed using a Toshiba Medical Systems 1.5 Tesla scanner. The in-plane artifact sizes were assessed as the maximum distance of the artifact from the expected region of the back.</p><p><strong>Results: </strong>All spinal structures or spinal cords can be recognized, even with valve-induced artifacts. The median maximum valve-induced artifact distance on T1-weighted axial imaging was 25.63 mm (mean, 25.98 mm ; range, 22.24-30.94 mm). The median maximum valve-induced artifact distance on T2-weighted axial imaging was 25.56 mm (mean, 26.27 mm ; range, 21.83-29.53 mm).</p><p><strong>Conclusion: </strong>LPS surgery with adjustable valve implantation on paravertebral muscles did not cause valve-induced artifacts in the spine and spinal cord. We considered that LPS could simplify the postoperative care of these patients. J. Med. Invest. 71 : 154-157, February, 2024.</p>","PeriodicalId":46910,"journal":{"name":"JOURNAL OF MEDICAL INVESTIGATION","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Spinal magnetic resonance imaging artifacts in lumboperitoneal shunt surgery using adjustable valve implantation on the paravertebral spinal muscles.\",\"authors\":\"Tatsuya Tanaka, Ryohei Sashida, Yu Hirokawa, Tomihiro Wakamiya, Yuhei Michiwaki, Kazuaki Shimoji, Eiichi Suehiro, Keisuke Onoda, Fumitaka Yamane, Akira Matsuno, Tadatsugu Morimoto\",\"doi\":\"10.2152/jmi.71.154\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Adjustable shunt valves that have been developed for managing hydrocephalus rely on intrinsically magnetic components ; thus, artifacts with these valves on magnetic resonance imaging (MRI) are inevitable. No studies on valve-induced artifacts in lumboperitoneal shunt (LPS) surgery have been published. Therefore, this study aimed to evaluate valve-induced artifacts in LPS.</p><p><strong>Methods: </strong>We retrospectively reviewed all MRIs obtained between January 2023 and June 2023 in patients with an implanted Codman CERTAS Plus adjustable shunt valve (Integra Life Sciences, Princeton, New Jersey, USA). The valve was placed <1 cm subcutaneously on the paravertebral spinal muscle of the back, with its long axis perpendicular to the body axis. The scans were performed using a Toshiba Medical Systems 1.5 Tesla scanner. The in-plane artifact sizes were assessed as the maximum distance of the artifact from the expected region of the back.</p><p><strong>Results: </strong>All spinal structures or spinal cords can be recognized, even with valve-induced artifacts. The median maximum valve-induced artifact distance on T1-weighted axial imaging was 25.63 mm (mean, 25.98 mm ; range, 22.24-30.94 mm). The median maximum valve-induced artifact distance on T2-weighted axial imaging was 25.56 mm (mean, 26.27 mm ; range, 21.83-29.53 mm).</p><p><strong>Conclusion: </strong>LPS surgery with adjustable valve implantation on paravertebral muscles did not cause valve-induced artifacts in the spine and spinal cord. We considered that LPS could simplify the postoperative care of these patients. J. Med. Invest. 71 : 154-157, February, 2024.</p>\",\"PeriodicalId\":46910,\"journal\":{\"name\":\"JOURNAL OF MEDICAL INVESTIGATION\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JOURNAL OF MEDICAL INVESTIGATION\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2152/jmi.71.154\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JOURNAL OF MEDICAL INVESTIGATION","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2152/jmi.71.154","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

背景:为治疗脑积水而开发的可调节分流瓣依赖于固有的磁性元件;因此,这些瓣膜在磁共振成像(MRI)上产生伪影是不可避免的。目前还没有关于腰腹腔分流术(LPS)手术中瓣膜引起的伪影的研究。因此,本研究旨在评估腰腹分流术中瓣膜引起的伪影:我们回顾性地检查了 2023 年 1 月至 2023 年 6 月期间植入 Codman CERTAS Plus 可调节分流瓣膜(Integra Life Sciences,美国新泽西州普林斯顿)患者的所有 MRI 图像。结果所有脊柱结构或脊髓都能识别,即使有瓣膜引起的伪影。T1加权轴向成像的最大瓣膜假影距离中位数为25.63毫米(平均值为25.98毫米;范围为22.24-30.94毫米)。T2加权轴向成像的最大瓣膜假影距离中位数为25.56毫米(平均值为26.27毫米;范围为21.83-29.53毫米):结论:在椎旁肌肉上植入可调节瓣膜的LPS手术不会在脊柱和脊髓中造成瓣膜诱导的伪影。我们认为 LPS 可以简化这些患者的术后护理。J. Med.Invest.71 : 154-157, February, 2024.
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Spinal magnetic resonance imaging artifacts in lumboperitoneal shunt surgery using adjustable valve implantation on the paravertebral spinal muscles.

Background: Adjustable shunt valves that have been developed for managing hydrocephalus rely on intrinsically magnetic components ; thus, artifacts with these valves on magnetic resonance imaging (MRI) are inevitable. No studies on valve-induced artifacts in lumboperitoneal shunt (LPS) surgery have been published. Therefore, this study aimed to evaluate valve-induced artifacts in LPS.

Methods: We retrospectively reviewed all MRIs obtained between January 2023 and June 2023 in patients with an implanted Codman CERTAS Plus adjustable shunt valve (Integra Life Sciences, Princeton, New Jersey, USA). The valve was placed <1 cm subcutaneously on the paravertebral spinal muscle of the back, with its long axis perpendicular to the body axis. The scans were performed using a Toshiba Medical Systems 1.5 Tesla scanner. The in-plane artifact sizes were assessed as the maximum distance of the artifact from the expected region of the back.

Results: All spinal structures or spinal cords can be recognized, even with valve-induced artifacts. The median maximum valve-induced artifact distance on T1-weighted axial imaging was 25.63 mm (mean, 25.98 mm ; range, 22.24-30.94 mm). The median maximum valve-induced artifact distance on T2-weighted axial imaging was 25.56 mm (mean, 26.27 mm ; range, 21.83-29.53 mm).

Conclusion: LPS surgery with adjustable valve implantation on paravertebral muscles did not cause valve-induced artifacts in the spine and spinal cord. We considered that LPS could simplify the postoperative care of these patients. J. Med. Invest. 71 : 154-157, February, 2024.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
JOURNAL OF MEDICAL INVESTIGATION
JOURNAL OF MEDICAL INVESTIGATION MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
1.20
自引率
0.00%
发文量
55
期刊最新文献
Changes in intestinal microbiota and biochemical parameters in patients with inflammatory bowel disease and irritable bowel syndrome induced by the prolonged addition of soluble fibers to usual drug therapy. Characterization of Outer Membrane Vesicles Produced by Vibrio vulnificus. Clarification of Psychiatric Nurses' Intentions and Analysis Contents in Observing Schizophrenia Patient. Current pharmacotherapies for advanced lung cancer with pre-existing interstitial lung disease : A literature review and future perspectives. Feasibility of laparoscopic and endoscopic cooperative surgery for gastric gastrointestinal stromal tumor with tumor diameter of >5 cm.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1