医护人员在移动的救护车上使用手持超声波设备对休克和低血压进行快速超声波检查:评估图像准确性和运动时间。

IF 2.1 4区 医学 Q2 EMERGENCY MEDICINE Prehospital and Disaster Medicine Pub Date : 2024-05-17 DOI:10.1017/S1049023X24000426
Burcu Azapoglu Kaymak, M. Ekşioğlu
{"title":"医护人员在移动的救护车上使用手持超声波设备对休克和低血压进行快速超声波检查:评估图像准确性和运动时间。","authors":"Burcu Azapoglu Kaymak, M. Ekşioğlu","doi":"10.1017/S1049023X24000426","DOIUrl":null,"url":null,"abstract":"INTRODUCTION\nHandheld ultrasound (US) devices have become increasingly popular since the early 2000s due to their portability and affordability compared to conventional devices. The Rapid Ultrasonography for Shock and Hypotension (RUSH) protocol, introduced in 2009, has shown promising accuracy rates when performed with handheld devices. However, there are limited data on the accuracy of such examinations performed in a moving ambulance. This study aimed to assess the feasibility and accuracy of the RUSH protocol performed by paramedics using handheld US devices in a moving ambulance.\n\n\nOBJECTIVES\nThe study aimed to examine the performability of the RUSH protocol with handheld US devices in a moving ambulance and to evaluate the accuracy of diagnostic views obtained within an appropriate time frame.\n\n\nMETHODS\nA prospective study was conducted with paramedics who underwent theoretical and practical training in the RUSH protocol. The participants performed the protocol using a handheld US device in both stationary and moving ambulances. Various cardiac and abdominal views were obtained and evaluated for accuracy. The duration of the protocol performance was recorded for each participant.\n\n\nRESULTS\nNine paramedics completed the study, with 18 performances each in both stationary and moving ambulance groups. The accuracy of diagnostic views obtained during the RUSH protocol did not significantly differ between the stationary and moving groups. However, the duration of protocol performance was significantly shorter in the moving group compared to the stationary group.\n\n\nCONCLUSION\nParamedics demonstrated the ability to perform the RUSH protocol effectively using handheld US devices in both stationary and moving ambulances following standard theoretical and practical training. The findings suggest that ambulance movement does not significantly affect the accuracy of diagnostic views obtained during the protocol. Further studies with larger sample sizes are warranted to validate these findings and explore the potential benefits of prehospital US in dynamic environments.","PeriodicalId":20400,"journal":{"name":"Prehospital and Disaster Medicine","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Rapid Ultrasonography for Shock and Hypotension Protocol Performed using Handheld Ultrasound Devices by Paramedics in a Moving Ambulance: Evaluation of Image Accuracy and Time in Motion.\",\"authors\":\"Burcu Azapoglu Kaymak, M. Ekşioğlu\",\"doi\":\"10.1017/S1049023X24000426\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"INTRODUCTION\\nHandheld ultrasound (US) devices have become increasingly popular since the early 2000s due to their portability and affordability compared to conventional devices. The Rapid Ultrasonography for Shock and Hypotension (RUSH) protocol, introduced in 2009, has shown promising accuracy rates when performed with handheld devices. However, there are limited data on the accuracy of such examinations performed in a moving ambulance. This study aimed to assess the feasibility and accuracy of the RUSH protocol performed by paramedics using handheld US devices in a moving ambulance.\\n\\n\\nOBJECTIVES\\nThe study aimed to examine the performability of the RUSH protocol with handheld US devices in a moving ambulance and to evaluate the accuracy of diagnostic views obtained within an appropriate time frame.\\n\\n\\nMETHODS\\nA prospective study was conducted with paramedics who underwent theoretical and practical training in the RUSH protocol. The participants performed the protocol using a handheld US device in both stationary and moving ambulances. Various cardiac and abdominal views were obtained and evaluated for accuracy. The duration of the protocol performance was recorded for each participant.\\n\\n\\nRESULTS\\nNine paramedics completed the study, with 18 performances each in both stationary and moving ambulance groups. The accuracy of diagnostic views obtained during the RUSH protocol did not significantly differ between the stationary and moving groups. However, the duration of protocol performance was significantly shorter in the moving group compared to the stationary group.\\n\\n\\nCONCLUSION\\nParamedics demonstrated the ability to perform the RUSH protocol effectively using handheld US devices in both stationary and moving ambulances following standard theoretical and practical training. The findings suggest that ambulance movement does not significantly affect the accuracy of diagnostic views obtained during the protocol. Further studies with larger sample sizes are warranted to validate these findings and explore the potential benefits of prehospital US in dynamic environments.\",\"PeriodicalId\":20400,\"journal\":{\"name\":\"Prehospital and Disaster Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-05-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Prehospital and Disaster Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1017/S1049023X24000426\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"EMERGENCY MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Prehospital and Disaster Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1017/S1049023X24000426","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

简介:与传统设备相比,手持式超声(US)设备因其便携性和经济性,自 21 世纪初以来越来越受欢迎。2009 年推出的休克和低血压快速超声检查(RUSH)方案显示,使用手持式设备进行检查的准确率很高。然而,有关在移动救护车中进行此类检查的准确性的数据却很有限。本研究旨在评估医护人员在移动的救护车上使用手持式 US 设备执行 RUSH 方案的可行性和准确性。方法对接受过 RUSH 方案理论和实践培训的医护人员进行了前瞻性研究。参加者在固定和移动的救护车上使用手持式 US 设备执行该方案。获得了各种心脏和腹部视图,并对其准确性进行了评估。结果九名护理人员完成了这项研究,在固定和移动救护车组中各进行了 18 次操作。在 RUSH 方案中获得的诊断视图的准确性在固定组和移动组之间没有明显差异。结论救护人员经过标准的理论和实践培训后,证明他们有能力在固定和移动救护车上使用手持 US 设备有效执行 RUSH 协议。研究结果表明,救护车的移动并不会明显影响协议中获得的诊断视图的准确性。有必要进行样本量更大的进一步研究,以验证这些发现,并探索院前 US 在动态环境中的潜在优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Rapid Ultrasonography for Shock and Hypotension Protocol Performed using Handheld Ultrasound Devices by Paramedics in a Moving Ambulance: Evaluation of Image Accuracy and Time in Motion.
INTRODUCTION Handheld ultrasound (US) devices have become increasingly popular since the early 2000s due to their portability and affordability compared to conventional devices. The Rapid Ultrasonography for Shock and Hypotension (RUSH) protocol, introduced in 2009, has shown promising accuracy rates when performed with handheld devices. However, there are limited data on the accuracy of such examinations performed in a moving ambulance. This study aimed to assess the feasibility and accuracy of the RUSH protocol performed by paramedics using handheld US devices in a moving ambulance. OBJECTIVES The study aimed to examine the performability of the RUSH protocol with handheld US devices in a moving ambulance and to evaluate the accuracy of diagnostic views obtained within an appropriate time frame. METHODS A prospective study was conducted with paramedics who underwent theoretical and practical training in the RUSH protocol. The participants performed the protocol using a handheld US device in both stationary and moving ambulances. Various cardiac and abdominal views were obtained and evaluated for accuracy. The duration of the protocol performance was recorded for each participant. RESULTS Nine paramedics completed the study, with 18 performances each in both stationary and moving ambulance groups. The accuracy of diagnostic views obtained during the RUSH protocol did not significantly differ between the stationary and moving groups. However, the duration of protocol performance was significantly shorter in the moving group compared to the stationary group. CONCLUSION Paramedics demonstrated the ability to perform the RUSH protocol effectively using handheld US devices in both stationary and moving ambulances following standard theoretical and practical training. The findings suggest that ambulance movement does not significantly affect the accuracy of diagnostic views obtained during the protocol. Further studies with larger sample sizes are warranted to validate these findings and explore the potential benefits of prehospital US in dynamic environments.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Prehospital and Disaster Medicine
Prehospital and Disaster Medicine Medicine-Emergency Medicine
CiteScore
3.10
自引率
13.60%
发文量
279
期刊介绍: Prehospital and Disaster Medicine (PDM) is an official publication of the World Association for Disaster and Emergency Medicine. Currently in its 25th volume, Prehospital and Disaster Medicine is one of the leading scientific journals focusing on prehospital and disaster health. It is the only peer-reviewed international journal in its field, published bi-monthly, providing a readable, usable worldwide source of research and analysis. PDM is currently distributed in more than 55 countries. Its readership includes physicians, professors, EMTs and paramedics, nurses, emergency managers, disaster planners, hospital administrators, sociologists, and psychologists.
期刊最新文献
Prehospital Care Under Fire: Strategies for Evacuating Victims from the Mega Terrorist Attack in Israel on October 7, 2023 Challenges and Clinical Impact of Medical Search and Rescue Efforts Following the Kahramanmaraş Earthquake. Integrating Disaster and Dignitary Medicine Principles into a Medical Framework for Organizational Travel Health and Security Planning. Applications and Performance of Machine Learning Algorithms in Emergency Medical Services: A Scoping Review. Rapid Ultrasonography for Shock and Hypotension Protocol Performed using Handheld Ultrasound Devices by Paramedics in a Moving Ambulance: Evaluation of Image Accuracy and Time in Motion.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1